Westell AR210 operational manual

SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Part # 030-1010xx
A90
Rev. P2, 07/01/98
S-0110P-A
C
AP RATE
E
THERNET
R
EMOTE UNIT
-A
DAPTIVE
DSL
(ATU-R)
A90-36R210
.
1
Printed in the USA
10BT-R.DOC
SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Part # 030-1010xx
A90
Rev. P2, 07/01/98
.
2
Printed in the USA
10BT-R.DOC
SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Part # 030-1010xx
A90
Rev. P2, 07/01/98
CONTENTS
CAP RATE-ADAPTIVE ETHERNET DSL REMOTE UNIT WITH FLASH (ATU-R)...................................................... 1
ENERAL DESCRIPTION
1. G
OCUMENT CONTROL
2. D
UILD CONTROL
3. B
OMPATIBILITY
4. C
NSPECTION
5. I
RODUCT OVERVIEW
6. P
...................................................................................................................................1
.....................................................................................................................................2
..........................................................................................................................................2
6.1 Features and Functions.................................................................................................................2
6.2 Transmission.................................................................................................................................3
6.3 Configuration.................................................................................................................................4
6.4 ATU-R Indicators...........................................................................................................................6
6.5 In te rfaces and Conne ctors............................................................................................................ 7
6.6 Signals...........................................................................................................................................9
6.7 10BaseT Ethernet DSL Diagnostics.............................................................................................. 9
6.8 System Status and Performance Management........................................................................... 10
LOCK DIAGRAM
7. B
PERATION
8. O
NSTALLATION
9. I
.................................................................................................................................10
........................................................................................................................................11
.....................................................................................................................................11
9.1 Unpa cking....................................................................................................................................11
9.2 In stallation Criteria.......................................................................................................................12
9.3 ATU-R Wiring..............................................................................................................................12
9.3.1 Installation with an Internal POTS Splitter...........................................................................13
9.3.2 Installation without an Internal POTS Splitter .....................................................................14
10. M
AINTENANCE
..................................................................................................................................15
10.1 Troubleshooting and Repair......................................................................................................15
10.2 Visual Inspection........................................................................................................ ................15
PECIFICATIONS
11. S
........................................................................................................................1
..........................................................................................................................1
............................................................................................................................2
...............................................................................................................................16
INDEX........................................................................................................................................................................................ 17
FCC NOTICE:........................................................................................................................................18
.
i
Printed in the USA
10BT-R.DOC
SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Part # 030-1010xx
A90
Rev. P2, 07/01/98
.
ii
Printed in the USA
10BT-R.DOC
SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Part # 030-1010xx
A90
Rev. P2, 07/01/98
CAP RATE-ADAPTIVE ETHERNET DSL
REMOTE UNIT WITH FLASH
(ATU-R)
1. General Description
The Ethernet DSL remote unit (ATU-R) (A90-36R210W00) terminates a DSL line at the subscrib er location. The 10BaseT Ethernet DSL system uses Carrierless Amp litud e Phase Modulation (CAP) transmission to provide reliable DSL transport over the existing copper cable infrastructure. The ATU-R separates CAP high-speed downstream and lower-speed upstream channel data and POTS (Plain Old Telephone Service) signals which have been transported via twis ted - pair c opper wires bet ween an acces s line m odul e at t he centr al office and the subscriber premises. The ATU-R provides an industry standard 10BaseT interface to the customer’s CPE equipment. Application software is fully downloadable to allow for future enhancements. The ATU-R is available with or without an optional internal POTS splitter.
ATU-R Op t ions CLEI FCC I D Number
A90-36R210 Without Internal POTS Splitter
VARTFMD1AA
CH8AR210
2. Document Control
Wh en ever th is sect ion of t he m anu al is revised , t h e reason wil l b e st ated in t h is su bs ection . Each time a revision is made, the revision level (located in the upper right corner) will be inc reased b y one l etter. In add ition , any c hang es in f it, form or fu nct ion of t he equip ment will cause the issue letter (located in the upper right corner) to be increased. An explanation of th e equip men t ch ang es wil l al so b e mad e in t h is su b sect ion. See t he
Overview
section of
this manual for additional information.
3. Build Control
The remote unit (ATU-R) is identified by an issue letter and model number imprinted on the bottom of the unit. Each time a change is made to the product which changes the form, fit or fu nction of the prod uct, the issue letter is advanced. Be sure to indicate the unit’s issue letter and model number when making inquiries about the product. The release number in the bottom left corner indicates the release(s) for which the module or section is valid.
.
1
Printed in the USA
10BT-R.DOC
SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Part # 030-1010xx
A90
Rev. P2, 07/01/98
A90-36R210-xxx
Issue Number
A90-36CP21R xxx
Model Number
W00
No internal POTS splitter
NA1
North American POTS Splitter
4. Compatibility
Refer to the System Overview (030-100983) section, Parag raph 5, for a comp lete list of all system element compatibil ity.
5. Inspection
Upon receipt, thoroughly inspect the remote unit for damage. If the remote unit has been damaged during transit, please report the damage immediately to the transportation company and to your Westell representative. Responsibility for safe delivery of goods is assured by the transportation carrier. Refer to the Section of this manual for further information.
Last three di gits indicate POTS Splitter options.
S-0146-A
SuperVision Service/Technical Support
6. Product Overview
The remote unit is located at the subscriber’s premises and terminates the digital subscriber line originatin g from the (ATU-C) in the central office.
The software within the ATU-R completely controls the hardware by providing an embedded system that implements a multiport learning MAC layer bridge that interfaces between Logical Link Control/Subnetwork Access Protocol (LLC/SNAP) AAL5 encapsulated ATM cell­bas ed, bridged protocol d ata u nit s ( P DUs ) and 10BaseT Eth er net frames . Th e AAL5 l ay er is the layer that supports connection-oriented, variable-bit-rate data services such as the typical "bursty" data traffic found in today's LANs. The LLC sublayer handles error control, flow control, framing, and MAC-sublayer addressing.
6.1 Features and Functions
The ATU-R provides a f lexibl e pl atform f or provid ing DS L services and app lication s. Th ese feat ures includ e:
No in-home configuration required. Once the ADSL line is provisioned by the telco,
the ATU-R is plug-and-play.
.
2
Printed in the USA
10BT-R.DOC
SuperVision® System Manual
CAP Rate-Adaptive Ethernet DSL Remote Unit
A90-36R210W00
Utilizes RADSL technology which supports rates from 640 kbps to 7.1 Mbps
Part # 030-1010xx
Rev. P2, 07/01/98
downstream and 91 kbp s to 1.088 Mb ps upst r eam .
Availab le options incl ude int ern al PO TS splitters cust omized to cou ntry-sp ecific PO TS
sp ec ificat ions or no inter nal PO TS s plitters where an external spl itter is preferred.
Support for fully automatic rate adaptation upon power-up, as well as support for
fixed r ate op er ation .
Tran slation between Ethernet MAC frames an d LLC/SNAP AAL5 encapsul ated ATM
bridged PDUs. In the ATM environment, this means that a PDU is sent through each relevant virtual circu it (VC).
10BaseT Eth ernet interface on customer sid e with high -speed ADSL-based network
side.
Support for up to eight simultaneous connections via ATM PVCs.
Status indicators via front panel LEDs.
Mul tiport MAC l ayer learn ing br idge im pl emented in sof tware. Th e brid ge assoc iates
a destin ation MAC address with an ATM PVC.
Support for statically provisioned MAC addresses.
Programm able h andl ing of E th er net broadcas t an d multic as t fr am es .
Programmable ATM QoS parameters for upstream traffic (towards network).
Offers centralized, software-controlled configuration, diagnostics and performance
monitoring.
System software is fully upgradadable via a standard web browser.
A90
6.2 Transmission
The system uses Carrierless Amplitud e Phase Mod ulation (CAP) technology t o deliver from 640 kbps to 7.1 Mbps downstream and 91 kbps to 1.088 Mbps upstream for data, while simultaneously providing lifeline POTS (Plain Old Telephone Service). Upstream is defined as from CPE to network and downstream from network to CPE.
The f ollowin g t able defines t he DSL s peed values at which t he u nit is capab le of operating .
.
3
Printed in the USA
10BT-R.DOC