6600 1/16 DIN Controller
with Heater Break Alarm
• Heater Break Alarms reduces scrap and
improves quality. Detection of heater loss
prior to production problems.
• Quick Transfer allows for ultra-easy setup of
Heater Break Alarms.
• Plug and Play Technology allows field
upgrades.
• Configuration directly from PC for fast and
repeatable configurations.
• Two Auto-tune algorithms: Pre-tune plus
Self-tune.
• Four Outputs available.
The 6600 is a 1/16 DIN controller that has been designed specifically to provide quality process control
for the Plastics Extrusion Market.
This control features a special Heater Break Alarm Function which works similar to an amp meter, but alerts
the operator to heater failures when they occur and prior
to production problems. Quick Transfer is a one shot
operation which automatically sets the alarm condition
for the heater break and is based on the nominal current value. Quick Transfer allows for the automatic entry of setpoints for the heater break alarm. In addition,
the Auto/Manual key can be configured for fast access
to display amps or process temperature by a single key
stroke.
Soft Start prevents premature heater failure due to high
levels of moisture in heaters at start-up. Soft Start is
included on this control, and is used to dry heaters out
prior to production. Soft-start is used in injection molding hot runner and other cartridge heater applications.
NEMA 4
The 6600 controller incorporates our advanced tuning
algorithms, with selectable pre-tune and self-tuning.
The pre-tune is used on start-up and is a one-step tuning algorithm designed to get you to setpoint fast with
self-tuning being enabled near setpoint and normal operating conditions to control overshoot. The self-tune
is a continuous tuning algorithm or sometimes referred
adaptive tuning
to as
fine tuned for specific applications.
This controller loaded up can have 4 outputs, 1 sensor
input, 1 current transformer input, and RS-485 Communication. Combining all these features makes the
West 6600 one of the most powerful controllers in its
class.
. This control can also be manual
39