Westcode Semiconductors N0290SC120, N0290SC160 Data Sheet

Date:- 23rd Sept 2014 Data Sheet Issue:- 3
VOLTAGE RATINGS
MAXIMUM
LIMITS
UNITS
V
DRM
Repetitive peak off-state voltage, (note 1)
1200-1600
V
V
DSM
Non-repetitive peak off-state voltage, (note 1)
1200-1600
V
V
RRM
Repetitive peak reverse voltage, (note 1)
1200-1600
V
V
RSM
Non-repetitive peak reverse voltage, (note 1)
1300-1600
V
OTHER RATINGS
MAXIMUM
LIMITS
UNITS
I
T(AV)
Mean on-state current, T
sink
=55°C, (note 2)
290
A
I
T(AV)
Mean on-state current. T
sink
=85°C, (note 2)
195
A
I
T(RMS)
Nominal RMS on-state current, T
sink
=25°C, (note 2)
578
A
I
T(d.c.)
D.C. on-state current, T
sink
=25°C, (note 4)
487
A
I
TSM
Peak non-repetitive surge tp=10ms, VRM=0.6V
RRM
, (note 5)
4200
A
I
TSM2
Peak non-repetitive surge tp=10ms, VRM10V, (note 5)
4620
A
I2t
I2t capacity for fusing tp=10ms, VRM=0.6V
RRM
, (note 5)
88.2×103
A2s
I2t
I2t capacity for fusing tp=10ms, VRM10V, (note 5)
107×103
A2s
(di/dt)cr
Maximum rate of rise of on-state current (repetitive), (Note 6)
500
A/µs
Maximum rate of rise of on-state current (non-repetitive), (Note 6)
1000
A/µs
V
FGM
Peak forward gate voltage
18
V
V
RGM
Peak reverse gate voltage
5
V
P
G(AV)
Mean forward gate power
2
W
PGM
Peak forward gate power
100
W
VGD
Non-trigger gate voltage, (Note 7)
0.25
V
THS
Operating temperature range
-40 to +125
°C
T
stg
Storage temperature range
-40 to +150
°C
Types N0290SC120 to N0290SC160
Absolute Maximum Ratings
Notes:-
1) De-rating factor of 0.13% per °C is applicable for T
2) Double side cooled, single phase; 50Hz, 180° half-sinewave.
3) Single side cooled, single phase; 50Hz, 180° half-sinewave.
4) Double side cooled.
5) Half-sinewave, 125°C T
6) V
=67% V
D
7) Rated V
, IFG=2A, tr0.5µs, T
DRM
.
DRM
initial.
j
=125°C.
case
Data Sheet. Types N0290SC120-160 Issue 3 Page 1 of 11 September 2014
below 25°C.
j
Fast Turn-Off Thyristor N0290SC120-N0290SC160
PARAMETER
MIN.
TYP.
MAX.
TEST CONDITIONS (Note 1)
UNITS
VTM
Maximum peak on-state voltage
- - 1.88
ITM=616A
V
VT0
Threshold voltage
- - 1.08 V
rT
Slope resistance
- - 1.3
m
(dv/dt)cr
Critical rate of rise of off-state voltage
200 - -
VD=80% V
DRM
V/s
I
DRM
Peak off-state current
- - 20
Rated V
DRM
mA
I
RRM
Peak reverse current
- - 20
Rated V
RRM
mA
VGT
Gate trigger voltage
- - 3.0
Tj=25°C
V
IGT
Gate trigger current
- - 150
Tj=25°C VD=10V, IT=3A
mA
IH
Holding current
- - 600
Tj=25°C
mA
R
thJK
Thermal resistance, junction to heatsink
- - 0.12
Double side cooled
K/W
F
Mounting torque
24.5 - 27 kN
Wt
Weight
-
280
- g
Characteristics
Notes:-
1) Unless otherwise indicated T
=125°C.
j
Data Sheet. Types N0290SC120-160 Issue 3 Page 2 of 11 September 2014
Fast Turn-Off Thyristor N0290SC120-N0290SC160
Voltage Grade
V
DRM VDSM VRRM
V
V
RSM
V
VD VR
DC V
12
1200
1300
810
16
1600
1700
1040
vqpulse ttt
f
1
max
Notes on Ratings and Characteristics
1.0 Voltage Grade Table
2.0 Extension of Voltage Grades This report is applicable to other and higher voltage grades when supply has been agreed by
Sales/Production.
3.0 Extension of Turn-off Time This Report is applicable to other tq/re-applied dv/dt combinations when supply has been agreed by
Sales/Production.
4.0 Repetitive dv/dt Higher dv/dt selections are available up to 1000V/µs on request.
5.0 De-rating Factor A blocking voltage de-rating factor of 0.13%/°C is applicable to this device for Tj below 25°C.
6.0 Rate of rise of on-state current The maximum un-primed rate of rise of on-state current must not exceed 1500A/µs at any time during
turn-on on a non-repetitive basis. For repetitive performance, the on-state rate of rise of current must not exceed 1000A/µs at any time during turn-on. Note that these values of rate of rise of current apply to the total device current including that from any local snubber network.
7.0 Square wave ratings These ratings are given for load component rate of rise of forward current of 100 and 500 A/µs.
8.0 Duty cycle lines The 100% duty cycle is represented on all the ratings by a straight line. Other duties can be included as
parallel to the first.
9.0 Maximum Operating Frequency The maximum operating frequency is set by the on-state duty, the time required for the thyristor to turn off
(tq) and for the off-state voltage to reach full value (tv), i.e.
Data Sheet. Types N0290SC120-160 Issue 3 Page 3 of 11 September 2014
Fast Turn-Off Thyristor N0290SC120-N0290SC160
HsJthAVSINKPAV
RWT and fEW
125
.)(max
HsJthoriginalSINKnewSINK
RfkETT
)()(
10.0 On-State Energy per Pulse Characteristics These curves enable rapid estimation of device dissipation to be obtained for conditions not covered by
the frequency ratings. Let Ep be the Energy per pulse for a given current and pulse width, in joules
Let R and T
Then the average dissipation will be:
11.0 Reverse Recovery Loss
11.1 Determination by Measurement
From waveforms of recovery current obtained from a high frequency shunt (see Note 1, Page 5) and reverse voltage present during recovery, an instantaneous reverse recovery loss waveform must be constructed. Let the area under this waveform be E joules per pulse. A new heat sink temperature can then be evaluated from:
be the steady-state d.c. thermal resistance (junction to sink)
th(J-Hs)
be the heat sink temperature.
SINK
where k = 0.227 (°C/W)/s E = Area under reverse loss waveform per pulse in joules (W.s.)
f = rated frequency Hz at the original heat sink temperature. R
= d.c. thermal resistance (°C/W).
th(J-Hs)
Data Sheet. Types N0290SC120-160 Issue 3 Page 4 of 11 September 2014