Westcode Semiconductors M0872LC140, M0872LC210 Data Sheet

Date:- 10 Mar, 2004
WESTCODE
An IXYS Company
Soft Recovery Diode
Type M0872LC140 to M0872LC210
(Old Type No.: SM14-21CXC224)
VOLTAGE RATINGS
V
RRM
V
RSM
I
F(AV)M
I
F(AV)M
I
F(AV)M
I
F(RMS)
I
f(d.c.)
I
FSM
I
FSM2
I2tI I2t T
j op
T
stg
Repetitive peak reverse voltage, (note 1) 1400-2100 V Non-repetitive peak reverse voltage, (note 1) 1400-2200 V
OTHER RATINGS
Maximum average forward current, T Maximum average forward current. T Maximum average forward. T Nominal RMS forward current, T D.C. forward current, T Peak non-repetitive surge tp=10ms, VRM=60%V Peak non-repetitive surge tp=10ms, VRM≤10V, (note 5)
2
t capacity for fusing tp=10ms, VRM=60%V
2
I
t capacity for fusing tp=10ms, VRM≤10V, (note 5) Operating temperature range -40 to +125 °C Storage temperature range -40 to +150 °C
sink
=85°C, (note 3) 332 A
sink
=25°C, (note 4) 1439 A
=55°C, (note 2) 872 A
sink
=85°C, (note 2) 577 A
sink
=25°C, (note 2) 1757 A
sink
, (note 5) 10 kA
RRM
, (note 5) 500×10
RRM
Data Sheet Issue:- 1
MAXIMUM
LIMITS
MAXIMUM
LIMITS
11 kA
3
3
605×10
UNITS
UNITS
A2s A2s
Notes:-
1) De-rating factor of 0.13% per °C is applicable for T
2) Double side cooled, single phase; 50Hz, 180° half-sinewave.
3) Single side cooled, single phase; 50Hz, 180° half-sinewave.
4) Double side cooled.
5) Half-sinewave, 125°C T
Data Sheet. Types M0872LC140 to M0872LC210 Issue 1 Page 1 of 11 March, 2004
initial.
j
below 25°C.
j
WESTCODE
WESTCODE An IXYS Company Soft Recovery Diode Type M0872LC140 to M0872LC210
WESTCODEWESTCODE

Characteristics

PARAMETER MIN. TYP. MAX. TEST CONDITIONS (Note 1) UNITS
V
V r
V
I Q Q I t
R
FM
T0
T
FRM
RRM
rr
ra
rm
rr
thJK
Maximum peak forward voltage
--1.5I
--1.7I Threshold voltage - - 1.09 V Slope resistance - - 0.34
Maximum forward recovery voltage
- - 30 di/dt = 1000A/µs, Tj=25°C
- - 40 di/dt = 1000A/µs Peak reverse current - - 50 Rated V Recovered charge - 700 - µC Recovered charge, 50% Chord - 280 320 µC Reverse recovery current - 140 - A Reverse recovery time, 50% Chord - 4.0 -
Thermal resistance, junction to heatsink
- - 0.044 Double side cooled
- - 0.088 Single side cooled
=1200A
FM
=1750A
FM
RRM
I
=1000A, tp=1000µs, di/dt=60A/µs,
FM
V
=50V, 50% Chord.
r
V
m
V
mA
µs
K/W
F Mounting force 10 - 20 kN W
Weight - 340 - g
t
Notes:-
1) Unless otherwise indicated T
=125°C.
j
Data Sheet. Types M0872LC140 to M0872LC210 Issue 1 Page 2 of 11 March, 2004
WESTCODE
WESTCODE An IXYS Company Soft Recovery Diode Type M0872LC140 to M0872LC210
WESTCODEWESTCODE

Notes on Ratings and Characteristics

1.0 Voltage Grade Table Voltage Grade V

14 1400 1500 930 16 1600 1700 1040 18 1800 1900 1150 20 2000 2100 1250 21 2100 2200 1300

2.0 De-rating Factor

A blocking voltage de-rating factor of 0.13% per °C is applicable to this device for Tj below 25°C.

3.0 ABCD Constants

These constants (applicable only over current range of VF characteristic in Figure 1) are the coefficients of the expression for the forward characteristic given below:
where IF = instantaneous forward current.

4.0 Reverse recovery ratings

RRM
(V)
V
RSM
(V)
IDICIBAV +++= )ln(
FFFF
V
dc
R
(V)
(i) Qra is based on 50% Irm chord as shown in Fig.(a) below.
(ii) Qrr is based on a 150µs integration time.
s
µ
150
I.e.
(iii)
=
FactorK =
dtiQ
.
rrrr
0
t
1
t
2
Data Sheet. Types M0872LC140 to M0872LC210 Issue 1 Page 3 of 11 March, 2004
WESTCODE
f
)
WESTCODE An IXYS Company Soft Recovery Diode Type M0872LC140 to M0872LC210
WESTCODEWESTCODE

5.0 Reverse Recovery Loss

The following procedure is recommended for use where it is necessary to include reverse recovery loss. From waveforms of recovery current obtained from a high frequency shunt (see Note 1) and reverse
voltage present during recovery, an instantaneous reverse recovery loss waveform must be constructed. Let the area under this waveform be E joules per pulse. A new sink temperature can then be evaluated from:
)(
Where k = 0.2314 (°C/W)/s
E
= Area under reverse loss waveform per pulse in joules (W.s.) = Rated frequency in Hz at the original sink temperature.
R
= d.c. thermal resistance (°C/W)
th(JK
The total dissipation is now given by:
originaltot

NOTE 1 - Reverse Recovery Loss by Measurement

This device has a low reverse recovered charge and peak reverse recovery current. When measuring the charge, care must be taken to ensure that:
(a) AC coupled devices such as current transformers are not affected by prior passage of high
amplitude forward current.
(b) A suitable, polarised, clipping circuit must be connected to the input of the measuring oscilloscope
to avoid overloading the internal amplifiers by the relatively high amplitude forward current signal.
[]
fEWW
)()(
+=
RfkETT +=
thJKMAXjSINK
(c) Measurement of reverse recovery waveform should be carried out with an appropriate critically damped snubber, connected across diode anode to cathode. The formula used for the calculation of this snubber is shown below:
2
R
Where: Vr= Commutating source voltage

6.0 Snubber Components When selecting snubber components, care m ust be taken not to us e excessively large values of snubber

capacitor or excessively sm all values of snubber re sistor. Such exc essive com ponent values may lead to device damage due to the large resultant values of snubber dis charge current. If required, please cons ult the factory for assistance.
V
= 4
C
R = Snubber resistance
r
di
C
dt
S
= Snubber capacitance
S