Westcode Semiconductors M0863LC260, M0863LC360 Data Sheet

Date:- 6 Nov, 2003
WESTCODE
An IXYS Company
Fast Recovery Diode
Type M0863LC260 to M0863LC360
Old Type No.: SM26-36CXC474
VOLTAGE RATINGS
V
RRM
V
RSM
I
F(AVM)
I
F(AVM)
I
F(AVM)
I
F(RMS)
I
f(d.c.)
I
FSM
I
FSM2
I2tI
I2t
T
j op
T
stg
Repetitive peak reverse voltage, (note 1) 2600-3600 V
Non-repetitive peak reverse voltage, (note 1) 2700-3700 V
OTHER RATINGS
Maximum average forward current, T
Maximum average forward current. T
Maximum average forward. T
Nominal RMS forward current, T
D.C. forward current, T
Peak non-repetitive surge tp=10ms, VRM=60%V
Peak non-repetitive surge tp=10ms, VRM≤10V, (note 5)
2
t capacity for fusing tp=10ms, VRM=60%V
2
t capacity for fusing tp=10ms, VRM≤10V, (note 5)
I
Operating temperature range -40 to +125 °C
Storage temperature range -40 to +150 °C
sink
=100°C, (note 3) 234 A
sink
=25°C, (note 4) 1451 A
=55°C, (note 2) 863 A
sink
=100°C, (note 2) 409 A
sink
=25°C, (note 2) 1721 A
sink
, (note 5) 10 kA
RRM
, (note 5) 500×10
RRM
Data Sheet Issue:- 1
MAXIMUM
LIMITS
MAXIMUM
LIMITS
11 kA
3
3
605×10
UNITS
UNITS
A2s
A2s
Notes:-
1) De-rating factor of 0.13% per °C is applicable for T
2) Double side cooled, single phase; 50Hz, 180° half-sinewave.
3) Single side cooled, single phase; 50Hz, 180° half-sinewave.
4) Double side cooled.
5) Half-sinewave, 125°C T
Data Sheet. Types M0863LC260 to M0863LC360 Issue 1 Page 1 of 11 November, 2003
initial.
j
below 25°C.
j
WESTCODE
WESTCODE An IXYS Company Fast Recovery Diode Types M0863LC260 to M0863LC360
WESTCODEWESTCODE
Characteristics
PARAMETER MIN. TYP. MAX. TEST CONDITIONS (Note 1) UNITS
V
V
r
T
Maximum peak forward voltage
FM
Threshold voltage - - 1.308 V
T0
--2.3I
Slope resistance - - 0.538
--2.1I
=1400A
FM
=1750A
FM
V
m
- - 160 di/dt = 1000A/µs
V
I
Q
Q
I
t
R
RRM
rm
rr
Maximum forward recovery voltage
FRM
Peak reverse current
Recovered charge - 950 - µC
rr
Recovered charge, 50% Chord - 370 475 µC
ra
Reverse recovery current - 150 - A
- - 90 di/dt = 1000A/µs, 25°C
- - 100 Rated V
- - 100 Rated V
I
FM
V
RRM
, Tj=25°C
RRM
=1000A, tp=1000µs, di/dt=60A/µs,
=50V, 50% Chord.
r
Reverse recovery time, 50% Chord - 4.8 -
- - 0.033 Double side cooled
Thermal resistance, junction to heatsink
thJK
- - 0.066 Single side cooled
V
mA
µs
K/W
F Mounting force 10 - 20 kN
W
Weight - 340 - g
t
Notes:-
1) Unless otherwise indicated T
=125°C.
j
Data Sheet. Types M0863LC260 to M0863LC360 Issue 1 Page 2 of 11 November, 2003
WESTCODE
WESTCODE An IXYS Company Fast Recovery Diode Types M0863LC260 to M0863LC360
WESTCODEWESTCODE

Notes on Ratings and Characteristics

1.0 Voltage Grade Table

Voltage Grade V
26 2600 2700 1500 28 2800 2900 1600 30 3000 3100 1700 32 3200 3300 1800 34 3400 3500 1850 36 3600 3600 1900

2.0 De-rating Factor

A blocking voltage de-rating factor of 0.13% per °C is applicable to this device for Tj below 25°C.

3.0 ABCD Constants

These constants (applicable only over current range of VF characteristic in Figure 1) are the coefficients of the expression for the forward characteristic given below:
where IF = instantaneous forward current.

4.0 Reverse recovery ratings

RRM
(V)
V
RSM
(V)
IDICIBAV +++= )ln(
FFFF
V
dc
R
(V)
(i) Qra is based on 50% Irm chord as shown in Fig.(a) below.
(ii) Qrr is based on a 150µs integration time.
s
µ
150
I.e.
(iii)
=
FactorK =
dtiQ
.
rrrr
0
t
1
t
2
Data Sheet. Types M0863LC260 to M0863LC360 Issue 1 Page 3 of 11 November, 2003
WESTCODE
f
)
WESTCODE An IXYS Company Fast Recovery Diode Types M0863LC260 to M0863LC360
WESTCODEWESTCODE

5.0 Reverse Recovery Loss

The following procedure is recommended for use where it is necessary to include reverse recovery loss.
From waveforms of recovery current obtained from a high frequency shunt (see Note 1) and reverse voltage present during recovery, an instantaneous reverse recovery loss waveform must be constructed. Let the area under this waveform be E joules per pulse. A new sink temperature can then be evaluated from:
[]
Where k = 0.2314 (°C/W)/s
E
= Area under reverse loss waveform per pulse in joules (W.s.) = Rated frequency in Hz at the original sink temperature.
R
The total dissipation is now given by:
This device has a low reverse recovered charge and peak reverse recovery current. When measuring the charge, care must be taken to ensure that:
amplitude forward current.
to avoid overloading the internal amplifiers by the relatively high amplitude forward current signal.
= d.c. thermal resistance (°C/W)
th(J-Hs
fEWW
originaltot

NOTE 1 - Reverse Recovery Loss by Measurement

(a) AC coupled devices such as current transformers are not affected by prior passage of high
(b) A suitable, polarised, clipping circuit must be connected to the input of the measuring oscilloscope
)()(
+=
RfkETT +=
)()( JKthMAXJSINK
(c) Measurement of reverse recovery waveform should be carried out with an appropriate critically damped snubber, connected across diode anode to cathode. The formula used for the calculation of this snubber is shown below:
2
R
Where: Vr= Commutating source voltage

6.0 Snubber Components

When selecting snubber components, care must be taken not to use excessively large values of snubber capacitor or excessively small values of snubber resistor. Such excessive component values may lead to device damage due to the large resultant values of snubber discharge current. If required, please consult the factory for assistance.
Data Sheet. Types M0863LC260 to M0863LC360 Issue 1 Page 4 of 11 November, 2003
V
= 4
C
R = Snubber resistance
r
di
C
dt
S
= Snubber capacitance
S
Loading...
+ 7 hidden pages