Westcode Semiconductors M0588LC400, M0588LC450 Data Sheet

Date:- 15 Nov, 2001
WESTCODE
Fast Recovery Diode
Types M0588LC400 to M0588LC450

Absolute Maximum Ratings

VOLTAGE RATINGS
V
RRM
V
RSM
I
F(AV)
I
F(AV)
I
F(AV)
I
F(RMS)
I
F(d.c.)
I
FSM
I
FSM2
I2tI I2t T
HS
T
stg
Repetitive peak reverse voltage, (note 1) 4000-4500 V Non-repetitive peak reverse voltage, (note 1) 4100-4600 V
OTHER RATINGS
Mean forward current, T Mean forward current. T Mean forward current. T Nominal RMS forward current, T D.C. forward current, T Peak non-repetitive surge tp=10ms, VRM=0.6V Peak non-repetitive surge tp=10ms, V
2
t capacity for fusing tp=10ms, VRM=0.6V
2
t capacity for fusing tp=10ms, V
I Operating temperature range -40 to +150 °C Storage temperature range -40 to +150 °C
(note 6)
=55°C, (note 2) 588 A
sink
=100°C, (note 2) 389 A
sink
=100°C, (note 3) 237 A
sink
=25°C, (note 2) 1108 A
sink
=25°C, (note 4) 969 A
sink
, (note 5) 3955 A
RRM
10V, (note 5)
RM
, (note 5) 78.2×10
RRM
10V, (note 5)
RM
Data Sheet Issue:- 1
LIMITS
LIMITS
4350 A
3
94.6×10
3
UNITS
UNITS
A2s A2s
Notes:-
1)
De-rating factor of 0.13% per °C is applicable for Tj below 25°C.
2)
Double side cooled, single phase; 50Hz, 180° half-sinewave.
3)
Single side cooled, single phase; 50Hz, 180° half-sinewave.
4)
Double side cooled.
5)
Half-sinewave, 150°C Tj initial.
Data Sheet. Types M0588LC400 to M0588LC450 Issue 1 Page 1 of 11 November, 2001
WESTCODE
Positive development in power electronics

Characteristics

M0588LC400 to M0588LC450
PARAMETER MIN. TYP. MAX. TEST CONDITIONS
V V r
S
Maximum peak forward voltage - - 4.8 IFM=1400A V
FM
Threshold voltage - - 2.32 V
0
Slope resistance - - 1.77
(Note 1)
UNITS
m
- - 140 di/dt = 1000A/µs
V
I Q Q I t
R
RRM
rm
rr
Maximum forward recovery voltage
FRM
Peak reverse current - - 100 Rated V Reverse Recovery Charge - 450 - µC
rr
Recovered charge, 50% Chord - 200 300 µC
ra
Reverse Recovery Current - 100 - A
- - 85 di/dt = 1000A/µs, Tj=25°C
RRM
I
=1000A, tp=1000µs, di/dt=60A/µs,
FM
=50V, 50% Chord.
V
r
Reverse recovery time, 50% Chord - 3.5 -
- - 0.033 Double side cooled
Thermal resistance, junction to heatsink
th(j-hs)
- - 0.066 Single side cooled
V
mA
µs
K/W
F Mounting force 10 - 20 kN W
Weight - 340 - g
t
Notes:-
1) Unless otherwise indicated T
=150°C.
j

Introduction

The M0588LC400-450 fast recovery diode range has controlled reverse recovery characteristics. Devices with a suffix code (2 letter or letter/digit/letter combination) added to their generic code are not
necessarily subject to the conditions and limits contained in this report.
Data Sheet. Types M0588LC400 to M0588LC450 Issue 1 Page 2 of 11 November, 2001
WESTCODE

Notes on Ratings and Characteristics

1.0 Voltage Grade Table

Positive development in power electronics
M0588LC400 to M0588LC450
Voltage Grade V
40 4000 4100 2000 42 4200 4300 2040 44 4400 4500 2080 45 4500 4600 2100

2.0 De-rating Factor A blocking voltage de-rating factor of 0.13% per °C is applicable to this device for Tj below 25°C.

3.0 ABCD Constants These constants (applicable only over current range of VF characteristic in Figure 1) are the coefficients of

the expression for the forward characteristic given below:
RRM
(V)
)ln(
where IF = instantaneous forward current.

4.0 Reverse recovery ratings (i) Qra is based on 50% Irm chord as shown in Fig.(a) below.

V
RSM
(V)
IDICIBAV
+++=
FFFF
V
dc
R
(V)
(ii) Qrr is based on a 150µs integration time.
s
µ
150
I.e.
(iii)
Data Sheet. Types M0588LC400 to M0588LC450 Issue 1 Page 3 of 11 November, 2001
=
FactorK
dtiQ
.
rrrr
0
t
1
=
t
2
WESTCODE
)

5.0 Reverse Recovery Loss

The following procedure is recommended for use where it is necessary to include reverse recovery loss. From waveforms of recovery current obtained from a high frequency shunt (see Note 1) and reverse
voltage present during recovery, an instantaneous reverse recovery loss waveform must be constructed. Let the area under this waveform be E joules per pulse. A new sink temperature can then be evaluated from:
Positive development in power electronics
M0588LC400 to M0588LC450
[]
Where k = 0.2314 (°C/W)/s
E
= Area under reverse loss waveform per pulse in joules (W.s.)
f
= Rated frequency in Hz at the original sink temperature.
R
The total dissipation is now given by:
This device has a low reverse recovered charge and peak reverse recovery current. When measuring the charge, care must be taken to ensure that:
amplitude forward current.
to avoid overloading the internal amplifiers by the relatively high amplitude forward current signal.
= d.c. thermal resistance (°C/W)
th(J-Hs
fEWW
originaltot

NOTE 1 - Reverse Recovery Loss by Measurement

(a) AC coupled devices such as current transformers are not affected by prior passage of high
(b) A suitable, polarised, clipping circuit must be connected to the input of the measuring oscilloscope
)()(
+=
+=
RfkETT
HsJthMAXJSINK
)()(
(c) Measurement of reverse recovery waveform should be carried out with an appropriate critically damped snubber, connected across diode anode to cathode. The formula used for the calculation of this snubber is shown below:
2
R
Where: Vr= Commutating source voltage
4
V
=
C
R = Snubber resistance
r
di
C
dt
S
= Snubber capacitance
S
Data Sheet. Types M0588LC400 to M0588LC450 Issue 1 Page 4 of 11 November, 2001
Loading...