Westcode Semiconductors F0240Y#250, F0240Y#300 Data Sheet

Date:- 27 Aug, 2004
WESTCODE
An IXYS Company
Extra Fast Recovery Diode
Types F0240Y#250 to F0240Y#300

Absolute Maximum Ratings

V
RRM
V
RSM
I
F(AV)M
I
F(AV)M
I
F(AV)M
I
F(RMS)
I
F(d.c.)
I
FSM
I
FSM2
I2tI I2t T
j op
T
stg
Repetitive peak reverse voltage, (note 1) 2500-3000 V Non-repetitive peak reverse voltage, (note 1) 2600-3100 V
OTHER RATINGS
Maximum average forward current, T Maximum average forward current. T Maximum average forward. T Nominal RMS forward current, T D.C. forward current, T Peak non-repetitive surge tp=10ms, VRM=60%V Peak non-repetitive surge tp=10ms, VRM≤10V, (note 5)
2
t capacity for fusing tp=10ms, VRM=60%V I2t capacity for fusing tp=10ms, VRM≤10V, (note 5) Operating temperature range -40 to +150 °C Storage temperature range -40 to +150 °C
sink
=100°C, (note 3) 87 A
sink
=25°C, (note 4) 374 A
=55°C, (note 2) 240 A
sink
=100°C, (note 2) 150 A
sink
=25°C, (note 2) 455 A
sink
, (note 5) 3100 A
RRM
, (note 5) 48.1 kA2s
RRM
Data Sheet Issue:- 1
MAXIMUM
LIMITS
MAXIMUM
LIMITS
3410 A
58.1 kA2s
UNITS
UNITS
Notes:-
1) De-rating factor of 0.13% per °C is applicable for T
2) Double side cooled, single phase; 50Hz, 180° half-sinewave.
3) Single side cooled, single phase; 50Hz, 180° half-sinewave.
4) Double side cooled.
5) Half-sinewave, 150°C T
Data Sheet. Types F0240Y#250 to F0240Y#300 Issue 1 Page 1 of 11 August, 2004
initial.
j
below 25°C.
j
WESTCODE
WESTCODE An IXYS Company Extra Fast Recovery Diode Types F0240Y#250 to F0240Y#300
WESTCODEWESTCODE

Characteristics

PARAMETER MIN. TYP. MAX. TEST CONDITIONS (Note 1) UNITS
V
V r
V
I Q Q I t
R
FM
T0
T
FRM
RRM
rr
ra
rm
rr
thJK
Maximum peak forward voltage
Threshold voltage - - 2.271 V Slope resistance - - 2.853
Maximum forward recovery voltage
Peak reverse current - - 50 Rated V Recovered charge - 100 - µC Recovered charge, 50% Chord - 40 55 µC Reverse recovery current - 40 - A Reverse recovery time, 50% Chord - 2 -
Thermal resistance, junction to heatsink
- - 4.12 IFM=635A
- - 3.70 I
=480A
FM
- - 70 di/dt = 1000A/µs, 25°C
- - 150 di/dt = 1000A/µs
RRM
I
=550A, tp=500µs, di/dt=40A/µs, Vr=50V,
FM
50% Chord.
- - 0.1 Double side cooled
- - 0.2 Single side cooled
V
m
V
mA
µs
K/W
F Mounting force 3.3 - 5.5 kN W
Weight - 140 - g
t
Notes:-
1) Unless otherwise indicated T
=150°C.
j
Data Sheet. Types F0240Y#250 to F0240Y#300 Issue 1 Page 2 of 11 August, 2004
WESTCODE
WESTCODE An IXYS Company Extra Fast Recovery Diode Types F0240Y#250 to F0240Y#300
WESTCODEWESTCODE

Notes on Ratings and Characteristics

1.0 Voltage Grade Table V

Voltage Grade
25 2500 2600 1500 26 2600 2700 1550 28 2800 2900 1650 30 3000 3100 1750

2.0 De-rating Factor

A blocking voltage de-rating factor of 0.13% per °C is applicable to this device for Tj below 25°C.

3.0 ABCD Constants

These constants (applicable only over current range of VF characteristic in Figure 1) are the coefficients of the expression for the forward characteristic given below:
where IF = instantaneous forward current.

4.0 Reverse recovery ratings

(i) Qra is based on 50% Irm chord as shown in Fig.(a) below.
RRM
(V)
V
RSM
(V)
V
dc
R
(V)
IDICIBAV +++= )ln(
FFFF
(ii) Qrr is based on a 150µs integration time.
s
µ
150
I.e.
(iii)
Data Sheet. Types F0240Y#250 to F0240Y#300 Issue 1 Page 3 of 11 August, 2004
=
FactorK =
dtiQ
.
rrrr
0
t
1
t
2
WESTCODE
f
WESTCODE An IXYS Company Extra Fast Recovery Diode Types F0240Y#250 to F0240Y#300
WESTCODEWESTCODE

5.0 Reverse Recovery Loss

The following procedure is recommended for use where it is necessary to include reverse recovery loss.
From waveform s of recovery current obtained from a high frequency shunt (see Note 1) and reverse voltage present during recovery, an instantaneous reverse recovery loss waveform must be constructed. Let the area under this waveform be E joules per pulse. A new sink tem per ature c an then be evaluated from:
)(
Where k = 0.2314 (°C/W)/s
E
= Area under reverse loss waveform per pulse in joules (W.s.) = Rated frequency in Hz at the original sink temperature.
R
= d.c. thermal resistance (°C/W)
thJK
The total dissipation is now given by:
originaltot

NOTE 1 - Reverse Recovery Loss by Measurement

This device has a low reverse recovered char ge and peak revers e recovery current. W hen m easuring the charge, care must be taken to ensure that:
(a) AC coupled devices such as current transformers are not affected by prior passage of high
amplitude forward current.
(b) A suitable, polarised, clipping circuit must be connected to the input of the measuring oscilloscope to avoid overloading the internal am plif ier s by the relatively high am plitude f or ward c urr ent signal.
)()(
[]
fEWW
+=
RfkETT +=
thJKMAXJSINK
(c) Measurement of reverse recovery waveform s hould be carried out with an appropriate critically damped snubber, connected across diode anode to cathode. T he formula used for the calculation of this snubber is shown below:
2
R
Where: Vr= Commutating source voltage

6.0 Snubber Components When selecting snubber components, care must be taken not to use excessively large values of

snubber capacitor or exces sively small values of s nubber resistor. Such excess ive component values may lead to device damage due to the large resultant values of snubber discharge current. If required, please consult the factory for assistance.
Data Sheet. Types F0240Y#250 to F0240Y#300 Issue 1 Page 4 of 11 August, 2004
V
= 4
C
R = Snubber resistance
r
di
C
dt
S
= Snubber capacitance
S
Loading...