CONVECTION OVEN
and
4 HOTPLATE COOKTOP
with
UNIVERSAL
HOOD
506
MODELS:
WVOC-4HF
WVOC-4HS
Includes
INSTALLATION
USE & CARE
EXPLODED VIEW
PARTS LIST
WIRING DIAGRAM
Model
WVOC-4HF
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
p/n 2M-304964 Rev. D M506 100420
Unless otherwise specified, all commercial cooking
equipment manufactured by WELLS BLOOMFIELD, LLC is
warranted against defects in materials and workmanship for
a period of one year from the date of original installation or
18 months from the date of shipment from our factory,
whichever comes first, and is for the benefit of the original
purchaser only.
THIS WARRANTY IS THE COMPLETE AND ONLY
WARRANTY, EXPRESSED OR IMPLIED IN LAW OR IN
FACT, INCLUDING BUT NOT LIMITED TO, WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE, AND/OR FOR DIRECT,
INDIRECT OR CONSEQUENTIAL DAMAGES IN
CONNECTION WITH WELLS BLOOMFIELD PRODUCTS.
This warranty is void if it is determined that, upon inspection
by an authorized service agency, the equipment has been
modified, misused, misapplied, improperly installed, or
damaged in transit or by fire, flood or act of God. It also
does not apply if the serial nameplate has been removed, or
if service is performed by unauthorized personnel. The
prices charged by Wells Bloomfield for its products are
based upon the limitations in this warranty. Seller’s
obligation under this warranty is limited to the repair of
defects without charge by a Wells Bloomfield factory
authorized service agency or one of its sub-service
agencies. This service will be provided on customer’s
premises for non-portable models. Portable models (a
device with a cord and plug) must be taken or shipped to
the closest authorized service agency, transportation
charges prepaid, for service. In addition to restrictions
contained in this warranty, specific limitations are shown in
the Service Policy and Procedure Guide. Wells Bloomfield
authorized service agencies are located in principal cities.
This warranty is valid in the United States and Canada and
void elsewhere. Please consult your classified telephone
directory, your foodservice equipment dealer or contact:
Wells Bloomfield, LLC
10 Sunnen Dr., P.O.Box 430129 St. Louis MO 63143 USA
phone (314) 781-2777 or fax (314) 781-2714
for information and other details concerning warranty.
LIMITED WARRANTY STATEMENT
SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by
skilled personnel before leaving the factory. Upon
acceptance of this shipment, the transportation company
assumes full responsibility for its safe delivery.
IF SHIPMENT ARRIVES DAMAGED:
1.VISIBLE LOSS OR DAMAGE: Be certain that any
visible loss or damage is noted on the freight bill or
express receipt, and that the note of loss or damage is
signed by the delivery person.
2.FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3.CONCEALED LOSS OR DAMAGE: if damage is
unnoticed until the merchandise is unpacked, notify the
transportation company or carrier immediately, and file
“CONCEALED DAMAGE” claim with them. This
should be done within fifteen (15) days from the date
the delivery was made to you. Be sure to retain the
container for inspection.
Wells Bloomfield cannot assume liability for damage or loss
incurred in transit. We will, however, at your request, supply
you with the necessary documents to support your claim.
SHIPPING DAMAGE CLAIM PROCEDURE
xi
1. Resetting of safety thermostats, circuit breakers, over
load protectors, and/or fuse replacements are notcovered by this warranty unless warranted conditions
are the cause.
2. All problems due to operation at voltages or phase
other than specified on equipment nameplates are
not covered by this warranty.
Conversion to correct voltage and/or phase must be
the customer’s responsibility.
3. All problems due to electrical connections not made
in accordance with electrical code requirements
and wiring diagrams supplied with the equipment are
not covered by this warranty.
4. Replacement of items subject to normal wear, to
include such items as knobs, light bulbs; and, normal
maintenance functions including adjustments of
thermostats, adjustment of micro switches and
replacement of fuses and indicating lights are notcovered by warranty.
5. Damage to electrical cords and/or plug due to exposure
to excessive heat are not covered by this warranty.
6. Full use, care, and maintenance instructions supplied
with each machine. Noted maintenance and
preventative maintenance items, such as servicing and
cleaning schedules, are customer responsibility. Those
miscellaneous adjustments noted are customer
responsibility. Proper attention to preventative
maintenance and scheduled maintenance procedures
will prolong the life of the appliance.
7. Travel mileage is limited to sixty (60) miles from an
Authorized Service Agency or one of its sub-service
agencies.
8. All labor shall be performed during regular working
hours. Overtime premium will be charged to the buyer.
9. All genuine Wells replacement parts are warranted for
ninety (90) days from date of purchase on nonwarranty equipment. This parts warranty is limited only
to replacement of the defective part(s). Any use of
non-genuine Wells parts completely voids any
warranty.
10. Installation, labor, and job check-outs are not
considered warranty and are thus not covered by this
warranty.
11. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technician’s ability to perform service are not covered by warranty. This
includes institutional and correctional facilities.
M506 2M-304964 Owners Manual WVOC-4H
TABLE OF CONTENTS
WARRANTY ................................................................ xi
PARTS & SERVICE....................................................... 41
CUSTOMER SERVICE DATA ..................................... 41
INTRODUCTION
Thank You for purchasing this Wells Bloomeld appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that
it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use and care for
the appliance in a manner which will ensure its optimum performance.
SPECIFICATIONS
AMPS 3ø
MODELVOLTSWATTS
WVOC-4HF
WVOC-4HS
Minimum clearances required from unit to nearest combustible
Fig. 1 Ventilator Section Features & Operating Controls
2
M506 2M-304964 Owners Manual WVOC-4H
FEATURES & OPERATING CONTROLS (continued)
VENTILATOR SECTION
ITEMDESCRIPTIONCOMMENT
1NAMEPLATE
a6.
a10.MANUAL PULL STATION
FIRE SUPPRESSION
AGENT TANK (1.5 gal.)
8ADJUSTABLE (FRONT) LEG Allows the unit to be leveled.
9RIGID (REAR) CASTER
Gives Manufacturer, Model and Serial Number information.
Also lists electrical specications.
Container for Ansulex™ Low-pH liquid re suppression liquid.
Allows the unit to be easily positioned by lifting the front of the unit
slightly.
Provides a means of manual activation of the re suppression
system. PULL ONLY IN CASE OF FIRE!
a11.FUSIBLE LINKS
12LOWER REAR ACCESS PANEL
a15.DISCHARGE NOZZLEFire suppression media discharges here (2 places).
16GREASE BAFFLE Extracts and drains most grease and moisture from the air ow.
18PRE-FILTER ASSEMBLY
19HEPA/CHARCOAL FILTER PACK
22GREASE CUP Collects grease/moisture drained from grease trough (23).
23GREASE TROUGHDirects grease/moisture removed by grease bafe to grease cup.
28VENTILATOR EXHAUST DUCT
a31.STATUS INDICATOR
38POWER CORD6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).
40FUSESProvide over-current protection of cooking appliance.
41POWER CONTACTOR
42BUILDING FIRE ALARM RELAYReports re alarm condition to building re management system.
43GROUND LUGGround wire of power cord connects here.
44INTERLOCK TERMINAL
Automatically activates re suppression system in the event of re
on the cooktop.
Allows access to Ansul® re suppression agent tank (a6) and
controls also access to main power contactor (41).
Comprises the PRE-FILTER FRAME and a replaceable PREFILTER. Stops larger particles of grease from reaching the FILTER
PACK for reduced maintenance costs.
Stops most grease and smoke particles. Also assists in some
cooking odor removal.
Exit point for ventilator airow - on top left rear of unit.
DO NOT BLOCK
Displays status of re suppression system (COCKED - FIRED) If
FIRED, a buzzer will sound continuously.
Energizes cooktop only while ventilator section is sensed as
operational.
Provides connection for shut-down control by building re
management system.
53FILTER INTERLOCK SWITCHES
M506 2M-304964 Owners Manual WVOC-4H
56VENTILATOR FANProvides air movement for ventilation.
58SIDE SPACERSMaintain required 6: spacing from combustible surfaces.
70COOLING FANProvides cooling for cooktop controls.
Proper installation of grease bafe and lter pack close these
switches in ventilator sensor circuit. Provides air movement for
ventilation.
Fig. 4 Convection Oven Operating Features & Controls
4
FEATURES & OPERATING CONTROLS (continued)
Item NO.DescriptionComments
VENTILATOR SECTION CONTROLS
V1POWER SWITCH
V2POWER ON INDICATOR
V3CHECK FILTERS ALARM INDICATORGREEN. Glows when POWER switch is ON.
V4*REPLACE PREFILTER ALARM INDICATOR
V5*REPLACE FILTER PACK ALARM INDICATOR
V6*SERVICE REQUIRED ALARM INDICATOR
* See PRECAUTIONS & GENERAL INFORMATION, pages 6 & 7 for special procedures regarding prelters and lter packs.
COOKTOP SECTION CONTROLS - HOTPLATE
H.01POWER ON INDICATOR
H.02HOTPLATE CONTROLInnite switch control of temperature of one hotplate section.
CONVECTION OVEN SECTION CONTROLS
C.01POWER-OFF-FAN SWITCHSwitch to turn oven ON, OFF or select FAN only.
C.02FAN LOW-OFF-HIGH SWITCHSwitch to turn fan ON, and to select fan speed.
C.03OVEN POWER INDICATORAMBER. Glows when oven is turned ON.
C.04HEAT INDICATORAMBER. Glows when heating elements are energized.
C.05DIGITAL DISPLAY
C.06OVEN TIME CONTROLAdjust programmed cooking time.
C.07OVEN TEMP CONTROLAdjust programmed cooking temperature.
C.08START TIMER KEYBegin a timed cook cycle.
C.09ACTUAL TEMP KEYPress to display current oven temperature.
C.10PGM KEYSPress to select pre-programmed time/temperature.
C.11CANCEL KEYPress to cancel a program in progress.
Energizes blower motor. If, after 10 seconds, proper conditions
are met, cooktop is energized.
AMBER. Glows if one or more lters are out of position.
Check all lters and bafes for proper installation.
AMBER. Glows when PREFILTER is approaching the end of its
service life and must soon be replaced.
AMBER. Glows when FILTER PACK is approaching the end of
its service life and must soon be replaced. RED. Glows when
PREFILTER and/or FILTER PACK has reached the end of its
service life and is too loaded to allow sufcient air ow. Filter
MUST be replaced. Appliance is SHUT DOWN until expended
lters are replaced.
AMBER. Glows when associated temperature control is turned
ON.
Displays time and temperature information.
Time remaining in program (minute : second)
Programmed temperature (ºF)
M506 2M-304964 Owners Manual WVOC-4H
5
PRECAUTIONS AND GENERAL INFORMATION
DANGER
ELECTRIC SHOCK HAZARD
DO NOT SPRAY WATER ON OR AROUND
ELECTRICAL EQUIPMENT
DO NOT WASH FLOOR NEAR ELECTRICAL
EQUIPMENT WITH WATER SPRAY
WARNING:
SHOCK HAzARD
All servicing requiring access
to non-insulated electrical
components must be
performed by a factory
authorized technician.
DO NOT open any access
panel which requires the use
of tools. Failure to follow this
warning can result in severe
electrical shock.
CAUTION:
RISK OF
DAMAGE
DO NOT connect or energize
this appliance until all
installation
instructions are read and
followed. Damage to the
appliance will result if these
instructions are not
followed.
NOTE: Fire suppression system and all associated components
must only be serviced by an authorized Ansul® Distributor. All setup,
charging, repair and/or adjustment of the re suppression system must
be performed by an Authorized Ansul® Distributor ONLY.
IMPORTANT: If a remote pull station is installed, both rear casters
(9) must be replaced with legs to deter moving the unit. MOVING AN
APPLIANCE WITH A REMOTE PULL STATION WILL DISCHARGE
THE FIRE SUPPRESSION SYSTEM.
This Ventless Cooking System™ is designed to help reduce odor
emissions, but will not completely eliminate cooking odors. Air
exchange at the installation site must comply with the requirements of
the local jurisdictional authority. To ensure that odors do not build-up,
recommended minimum air exchange is 300 - 400 cfm of outside air
into and out of the area where the unit is used. Recommend use of
wall fan and wall switch, to be supplied by user.
This appliance is intended for use in commercial establishments
only.
This appliance is intended
to prepare food for human consumption.
No other use is recommended or authorized by the manufacturer or its
agents.
Operators of this appliance must be familiar with the appliance use,
limitations and associated restrictions. Operating instructions must be
read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation. Read and
follow all included cleaning instructions and schedules to ensure the
safety of the food product.
Disconnect this appliance from electrical power before performing any
maintenance or servicing.
Do not splash or pour water on, in or over any exposed element,
control, control panel or wiring.
DO NOT submerge pre-lter or lter pack in water.
The technical content of this manual, including any wiring diagrams,
schematics, parts breakdown illustrations and/or adjustment
procedures, is intended for use by qualied technical personnel.
Any procedure which requires the use of tools must be performed by a
qualied technician.
This manual is considered to be a permanent part of the appliance.
This manual and all supplied instructions, diagrams, schematics, parts
breakdown illustrations, notices and labels must remain with the
appliance if it is sold or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this
appliance has American sizes on all hardware.
M506 2M-304964 Owners Manual WVOC-4H
6
PRECAUTIONS AND GENERAL INFORMATION (continued)
OPERATIONAL NOTES:
REPLACE PREFILTER and REPLACE FILTER PACK indicator lights
provide a timely warning that a system shut-down is imminent.
The actual time between the indicator light coming on and the loss of
cooking appliance power will depend upon the cooking conditions.
Anytime a dirty PRE-FILTER is replaced, the system airow will
increase. If the condition of the FILTER PACK is marginal, the
REPLACE FILTER PACK light could then come on. If this happens,
a fresh FILTER PACK must be installed within a reasonably short time.
Loss of airow through the old lter pack will soon cause a system
shut-down when the airow falls below minimum vapor capture levels.
KEEP SPARE FILTER PACKS ON HAND.
IMPORTANT: If you decide to “get the most” out of the old lter pack,
and continue to use it until a system shut-down happens, it is advisable
to have a fresh lter pack readily at hand, and have someone available
who is capable of replacing it. Otherwise, you may experience an
extended down time, with consequent associated loss of business.
The manufacturer assumes no liability for loss of business due to
a system shutdown caused by a dirty pre-lter and/or lter pack
(i.e. red SERVICE REQUIRED light is on), when the user fails to
have the proper replacement pre-lter and/or lter pack on hand.
The Ventless Cooking System™ hood is designed as part of a WELLS cooking appliance only. No other use of this product is authorized by
the manufacturer or its agents. Wells Mfg. assumes no liability for the
use of this equipment with products by any other manufacturer’s, or for
use of this equipment with any Wells Manufacturing product other than
in factory certied applications.
AGENCY LISTING INFORMATION
This appliance conforms to NSF Standard 4 for sanitation only if
installed in accordance with the supplied Installation Instructions
And operated and maintained in accordance with the instructions
in this manual.
This appliance is listed under UL File E146882.
Fig. 5 Ventilator
Warning
Indicators
STD 4
E146882
M506 2M-304964 Owners Manual WVOC-4H
7
INSTALLATION
NOTE: DO NOT discard
the carton or other packing
materials until you have
inspected the appliance for
hidden damage and tested it
for proper operation.
Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the
inside front cover of this
manual.
WARNING:
RISK OF
INjURY
Installation procedures must
be performed by a qualied
technician with full knowledge
of all applicable electrical
codes. Failure can result in
personal injury and property
damage.
WARNING:
FIRE HAzARD
Avoid storing ammable or
combustible materials near
the appliance.
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all
protective plastic lm, packing materials and accessories from the
Appliance before connecting electrical power or otherwise performing
any installation procedure.
Carefully read all instructions in this manual and the InstallationInstruction Sheet packed with the appliance before starting any
installation.
Read and understand all labels and diagrams attached to the
appliance.
Carefully account for all components and accessories before
discarding packing materials. Store these components in or near the
appliance for later use. These items must be installed before operating
the appliance.
1 ea. FIRE SUPPRESSION AGENT (ANSULEX® Low pH, 1.5 GAL.)
See Material Safety Data Sheet, page 28.
1 ea. FIRE SUPPRESSION MEDIA TANK
1 ea. FIRE SUPPRESSION TANK CHARGING CARTRIDGE
1 ea. GREASE BAFFLE
1 ea. FILTER PACK ASSEMBLY
1 ea. PRE-FILTER HOLDER with PRE-FILTER
1 ea. GREASE CUP
1 ea. GREASE TROUGH
2 ea. 6” SIDE SPACERS
Setup the appliance only on a rm level surface. Non-combustible
material is recommended.
Refer to the Installation Instruction Sheet for required clearances.
Maintain required clearances between the appliance and adjacent
combustible surfaces. Verify 6” left and right side clearances to
combustible construction. This appliance requires a minimum of 8 ft
(96”) (oor to overhead) to allow for adequate exhaust.
IMPORTANT: Provided 6” side spacers (item 58) must be installed on
the appliance.
Verify that the VENTILATOR HOOD ASSEMBLY is properly and
securely assembled to the cooking appliance before beginning the
installation procedure.
If a remote manual pull station is to be installed, replace the rear
casters with legs.
Level the unit after it is in its nal position. Using a spirit level, verify
that the unit is level front-to-back and side-to-side.
M506 2M-304964 Owners Manual WVOC-4H
8
INSTALLATION (continued)
SERVICE TECHNICIAN INSTALLATION NOTES
An Ansul® technician must charge and arm the re suppression system
before the ventilator blower will operate. See page 10.
Installation and start up must be performed by an Authorized
Installation Company.
Installer must complete the WARRANTY REGISTRATION form, and
record appliance installation particulars on the CUSTOMER SERVICE
DATA form in this manual.
Certain codes require cooking equipment to be restrained with
a RESTRAINT DEVICE. It is the RESPONSIBILITY OF THE
INSTALLER to check with the AUTHORITY HAVING jURISDICTION,
in order to ascertain the applicability of this requirement to THIS
SPECIFIC EQUIPMENT INSTALLATION. Any restraint device must
allow access to the back and sides of the unit to provide for servicing
and maintenance, and must not interfere with the operation of the FIRE
SUPPRESSION SYSTEM.
ELECTRICAL INSTALLATION
1. This appliance must be installed by a licensed electrician in
accordance with all applicable codes and ordinances.
Electrical connection terminal block and ground lug are accessible
by removing the right side panel.
2. Refer to the nameplate on the right side of the appliance. Verify the
ELECTRICAL SERVICE POWER. Voltage and phase must match
the nameplate specications, and available electrical service
amperage must meet or exceed the specications listed on page 1
Wiring must be no less than 4 AWG solid copper wire, rated for at
least 90ºC.
NOTE: Wire gauge, insulation type and temperature rating , as
well as type, size and construction of conduit, must meet or exceed
applicable specications of local codes and of the National
Electrical Code.
3. This appliance must be connected to a suitable building ground.
The equipment ground connection is marked “ “.
4. The appliance is shipped from the factory wired for 3-phase
electrical service. Refer to the Wiring Diagram included with this
appliance, and verify that eld wiring conforms to this diagram.
IMPORTANT: This appliance is not approved for 1Ø operation.
Conversion of this appliance to single-phase operation will void the
warranty.
M506 2M-304964 Owners Manual WVOC-4H
IMPORTANT!
Verify that this VENTILATOR
and food cooking equipment
installation is in compliance
with the specications listed
in this manual, with local
code requirements, and in
accordance with N.F.P.A
96 (THE STANDARD FOR
VENTILATION CONTROL
AND FIRE PROTECTION
OF COMMERCIAL
COOKING OPERATIONS
- current edition).
THIS IS THE
RESPONSIBILITY
OF THE INSTALLER
DANGER
ELECTRIC
SHOCK
HAzARD
ELECTRIC CONNECTIONS
MUST BE MADE BY A
LICENSED ELECTRICIAN
Electrical shock will cause
death or serious injury.
CAUTION:
ELECTRIC
SHOCK HAzARD
The ground lug of this
appliance must be connected
to a suitable building ground.
NOTE: This appliance
requires a dedicated 60
Amp electrical branch circuit
protection.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
9
INSTALLATION (continued)
DANGER
FIRE
HAzARD
THE FIRE SUPPRESSION
SYSTEM MUST BE
CHARGED AND CERTIFIED
BY AN AUTHORIZED
ANSUL® DISTRIBUTOR.
NEVER ATTEMPT TO
MODIFY OR BYPASS
THE FIRE SUPPRESSION
SYSTEM.
AN UNCONTROLLED FIRE
CAN CAUSE SERIOUS
INjURY, DEATH AND/OR
PROPERTY LOSS.
IMPORTANT: The FIRE
SUPPRESSION SYSTEM
must be SET-UP and
CHARGED by an authorized
Ansul® distributor before the
ventilator blower will operate.
NOTE: If the re
suppression system is
discharged, a buzzer will
sound continuously and
the cooking appliance will
remain inoperable until the
re suppression system is
serviced. Recharging and
resetting must be performed
by an authorized Ansul®
distributor ONLY.
Charging of the Ansul Fire
Suppression system must be
in accordance with Ansul®
FIRE SUPPRESSION SYSTEM INSTALLATION
1. Any REMOTE MANUAL PULL STATION must be installed by an
authorized ANSUL® distributor in accordance with the
AUTHORITY HAVING jURISDICTION.
NOTE: If a REMOTE MANUAL PULL STATION is installed, moving
the unit for servicing will cause the Ansul® system to discharge.
In this case, the unit must only be installed with four xed legs
(i.e. remove rear casters and replace with legs). Additional legs
may be ordered through an Authorized Wells Service Agency. See
page 25.
2. The FIRE SUPPRESSION SYSTEM is comprised of a
pressurized cartridge
& container of liquid
re suppressant, with
associated plumbing and
controls. It utilizes factory
installed FUSIBLE LINKS
for automatic actuation,
and a factory installed
MANUAL PULL STATION
for manual actuation.
Two NOZZLES are used
to disperse the liquid re
suppression media.
3. When the re suppression
system activates, the
re suppression media
is discharged, both the
cooking appliance and
the ventilator are deenergized, and a buzzer
will sound continuously.
The re suppression media will form an emulsion designed to both
smother and cool the re.
Call your Authorized Ansul® Distributor immediately for service.
NOTE: See page 28 for the Material Safety Data Sheet for the re
suppression agent.
4. The MANUAL PULL STATION and any similar REMOTE MANUAL
PULL STATION will activate the re suppression system when the
ring on the pull station is pulled horizontally.
10
Fig. 6 Fire Suppression System
M506 2M-304964 Owners Manual WVOC-4H
INSTALLATION (continued)
FILTER
RA IL
FILTER
HO O K
FILTER PA CK
PRE -FILTER
ASS EM BLY
GREA S E
BAF FLE
GREA S E
TR O U G H
GREA S E
CUP
A
IR
F
L
O
W
HOLD ER C LIP
FILTER PA CK
POSITION
SWITCH
GREA S E B AFFLE
POSITION
SWITCH
FILTER PA CK
SEA L
PRE -FILTER
NOTE : AIR F LOW ARROW
POINTS FROM
INSTALLE R W HEN
PRO P E RLY INSTALLED
AWAY
FILTER
FR A M E
NOTE : P RE-F ILTE R IS SENSE D
AS BEING IN POSITION BY THE
PRE S SURE DROP AC R O S S IT.
FILTER HOOK
FILTER
HAN D LE
FILTER PACK
SEA L
HO LDE R CL IP
CL IP S ON TO
LE DGE
W
A
L
L
O
F
U
N
IT
P
R
E
-
F
I
L
T
E
R
FILTERS INSTALLATION
FILTER PACK: Ships installed in the hood. If the FILTER PACK is not
in position, the CHECK FILTERS indicator will light.If the FILTER
PACK becomes clogged, the REPLACE FILTER PACK indicator will
glow.
To install the FILTER PACK: Position the lter pack with the charcoal
portion UP. Slide the lter pack toward the rear of the unit until it
contacts the guides on the back panel. Push the lter pack UP into
the upper opening until it rests rmly against the lter pack seal.
When up in position, holder clips can be snapped over wall ledge on
each side. To remove FILTER PACK: Grasp both holder clips and
pull INWARD until the clips clear the sidewall ledge. Then, pull the
lter pack down and out.
PRE-FILTER: The PRE-FILTER ships in the FILTER FRAME. If the
PRE-FILTER is not in position, or if the PRE-FILTER is not in the
FILTER FRAME, the CHECK FILTERS indicator will light.
If the PRE-FILTER becomes clogged, the REPLACE PRE-FILTER
indicator will glow.
To install the PRE-FILTER: Pay attention to the air ow markings.
The AIR FLOW arrow will point away from the installer. Slide the
assembly up into the front opening, behind the upper lter rail.
While pressing slightly against the bottom of the assembly, pull the
FILTER HANDLE toward you so as to engage the FILTER HOOK
over the lip of the top lter rail. Then lower and seat the assembly
into the top indentation of the lower lter rail.
NOTE:
The GREASE BAFFLE and
FILTER PACK activate
mechanical switches, and the
PRE-FILTER activates a
vacuum switch, to verify that
the lter elements are in their
proper positions.
All lter elements must be
properly installed or the
cooktop will not be energized.
Also, the CHECK FILTERS
indicator will light.
IMPORTANT:
The lter hook prevents the
PRE-FILTER from being
drawn in during operation.
After installation, press
against the top of the lter
frame to verify proper
engagement of the lter hook
over the lip of the top lter
rail.
GREASE BAFFLE:
FILTERS indicator will glow.
To install the GREASE BAFFLE: Slide the grease bafe up into
the indentation of the upper lter rail, then lower and seat it into the
bottom indentation of the lower lter rail. Pull toward you and
downward to verify the GREASE BAFFLE is properly seated in the
lower frame rail.
M506 2M-304964 Owners Manual WVOC-4H
If the GREASE BAFFLE is not in place, the CHECK
Fig. 7 Filter Installation
11
INSTALLATION (continued)
WARNING
SLIP / FALL
HAZARD
SPILLED OIL
DO NOT OPERATE UNLESS
THE GREASE CUP IS
INSTALLED.
Oil and moisture will drip onto
the oor and falls may result.
Death or serious
injury may result
from slipping and
falling
GREASE TROUGH AND GREASE CUP INSTALLATION
1. Install the GREASE TROUGH into the brackets below the grease
bafe.
2. Install the GREASE CUP on the right side of the unit, directly
below the grease trough.
OVEN RACK INSTALLATION
1. Install fan bafe. Use care around the fan. The blades are sharp.
2. Install one rack support on the fan bafe, and one rack support on
the left wall of the oven cavity.
3. Install racks as needed for the product being prepared.
CAUTION:
BURN HAZARD
DO NOT OPERATE UNLESS
GREASE TROUGH
IS INSTALLED.
Moisture will drip into the hot
cooking surface, causing
splattering of hot liquids.
Serious injury can result from
contact with hot splatter.
Fig. 8 Oven Rack Installation
M506 2M-304964 Owners Manual WVOC-4H
12
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.