Wells Manufacturing WV2HFG, WV2HFGRW, WV2HFGRWT, WV2HSG, WV2HSGRW Operation Manual

...
WELLS BLOOMFIELD, LLC
10 Sunnen Dr., St. Louis, MO 63143
telephone: 314-678-6314
fax: 314-781-2714
www.wells-mfg.com
OWNERS MANUAL
WV2HG SERIES
GRIDDLE / HOTPLATE
UNIVERSAL HOOD
508
COOKTOP
with
MODELS:
WV2HFG
WV2HFGRW
WV2HFGRWT
WV2HSG
WV2HSGRW
WV2HSGRWT
Includes
INSTALLATION
USE & CARE
EXPLODED VIEW
PARTS LIST
WIRING DIAGRAM
WV-2HGRW
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
p/n 2M-304456 Rev. E M508 120209
LIMITED WARRANTY STATEMENT
Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser only. THIS WARRANTY IS THE COMPLETE AND ONLY WARRANTY, EXPRESSED OR IMPLIED IN LAW OR IN FACT, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND/OR FOR DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH WELLS BLOOMFIELD PRODUCTS. This warranty is void if it is determined that, upon inspection by an authorized service agency, the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God. It also does not apply if the serial nameplate has been removed, or if service is performed by unauthorized personnel. The prices charged by Wells Bloomfield for its products are
based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Wells Bloomfield factory authorized service agency or one of its sub-service agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest authorized service agency, transportation charges prepaid, for service. In addition to restrictions contained in this warranty, specific limitations are shown in the Service Policy and Procedure Guide. Wells Bloomfield authorized service agencies are located in principal cities. This warranty is valid in the United States and Canada and void elsewhere. Please consult your classified telephone directory, your foodservice equipment dealer or contact:
10 Sunnen Dr., St. Louis MO 63143 USA
phone (314) 678-6314 or fax (314) 781-2714
for information and other details concerning warranty.
Wells Bloomfield, LLC
SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers, over load protectors, and/or fuse replacements are not covered by this warranty unless warranted conditions are the cause.
2. All problems due to operation at voltages or phase other than specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage and/or phase must be the customer’s responsibility.
3. All problems due to electrical connections not made
in accordance with electrical code requirements and wiring diagrams supplied with the equipment are
not covered by this warranty.
4. Replacement of items subject to normal wear, to include such items as knobs, light bulbs; and, normal maintenance functions including adjustments of thermostats, adjustment of micro switches and replacement of fuses and indicating lights are not covered by warranty.
5. Damage to electrical cords and/or plug due to exposure to excessive heat are not covered by this warranty.
6. Full use, care, and maintenance instructions supplied with each machine. Noted maintenance and
preventative maintenance items, such as servicing and
cleaning schedules, are customer responsibility. Those miscellaneous adjustments noted are customer responsibility. Proper attention to preventative maintenance and scheduled maintenance procedures will prolong the life of the appliance.
7. Travel mileage is limited to sixty (60) miles from an Authorized Service Agency or one of its sub-service agencies.
8. All labor shall be performed during regular working hours. Overtime premium will be charged to the buyer.
9. All genuine Wells replacement parts are warranted for ninety (90) days from date of purchase on non­warranty equipment. This parts warranty is limited only to replacement of the defective part(s). Any use of
non-genuine Wells parts completely voids any
warranty.
10. Installation, labor, and job check-outs are not
considered warranty and are thus not covered by this warranty.
11. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technician’s ability to perform service are not covered by warranty. This includes institutional and correctional facilities.
M508 p/n 2M-304456 Owners Manual WV-2HG
SHIPPING DAMAGE CLAIM PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This should be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Wells Bloomfield cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
TABLE OF CONTENTS
WARRANTY ................................................................ xi
SPECIFICATIONS ....................................................... 1
FEATURES & OPERATING CONTROLS ................... 2
PRECAUTIONS & GENERAL INFORMATION ........... 6
AGENCY LISTING INFORMATION ............................ 8
INSTALLATION ........................................................... 9
OPERATION ............................................................... 14
CLEANING INSTRUCTIONS ...................................... 18
MAINTENANCE INSTRUCTIONS .............................. 22
TROUBLESHOOTING SUGGESTIONS ..................... 23
MAINTENANCE SCHEDULES ................................... 24
MSDS (Ansulex Low pH) ............................................. 27
ANSUL® COMPONENTS ........................................... 29
EXPLODED VIEW & PARTS LIST .............................. 30
WIRING DIAGRAM ..................................................... 34
PARTS & SERVICE .................................................... 37
CUSTOMER SERVICE DATA ..................................... 37
INTRODUCTION
Thank You for purchasing this Wells Bloomfield appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance, and to use and care for the appliance in a manner which will ensure its optimum performance.
SPECIFICATIONS
MODEL
WV-2HFG NO
WV-2HFGRW
WV-2HFGRWT
WV-2HSG NO
WV-2HSGRW
WV-2HSGRWT
M508 p/n 2M-304456 Owners Manual WV-2HG
ROLL
WARMER
YES
YES
VOLTS
50/60 Hz
208V 16 32 23 38 8,000
240V 18 35 24 41 9,900
208V 21 35 24 43 8,900
240V 23 38 24 46 11,100
208V 19 32 26 42 8,675
240V 21 35 27 45 10,800
208V 23 35 26 46 9,575
240V 26 38 27 50 12,000
Minimum clearances required from unit to nearest combustible surface or object
3ø AMPS
L1 L2 L3
AMPS WATTS
DIMENSIONS
POWER CORD
30-3/8” WIDE
(42-3/8" wide including spacers)
79-1/8” HIGH
35-3/8” DEEP
Power Cord (when provided):
NEMA 15-60P
BACK SIDE BOTTOM TOP
inches n/a 6 6 19
millimeters n/a 152 152 483
1
FEATURES & OPERATING CONTROLS
Fig. 1 Ventilator Section Operating Features & Controls
2
M508 p/n 2M-304456 Owners Manual WV-2HG
VENTILATOR SECTION
FEATURES & OPERATING CONTROLS (continued)
ITEM
1.
5.
a6.
8.
9.
a10.
a11.
12.
a15.
16.
18.
19.
22.
28.
a31.
38.
41.
42.
43.
44.
53.
56.
M508 p/n 2M-304456 Owners Manual WV-2HG
57.
58.
DESCRIPTION
NAMEPLATE
APPLIANCE LIGHT
FIRE SUPPRESSION AGENT TANK (1.5 gal.)
ADJUSTABLE (FRONT) LEG
RIGID (REAR) CASTER
MANUAL PULL STATION
FUSIBLE LINKS
LOWER REAR ACCESS PANEL
DISCHARGE NOZZLE
GREASE BAFFLE
PRE-FILTER ASSEMBLY
HI-EFFICIENCY/CHARCOAL FILTER PACK
GREASE DRIP TRAY
VENTILATOR EXHAUST DUCT
STATUS INDICATOR
POWER CORD
POWER CONTACTOR
BUILDING FIRE ALARM RELAY
GROUND LUG
INTERLOCK TERMINAL
FILTER INTERLOCK SWITCHES
VENTILATOR FAN
HOOD SIDE SHIELD
SIDE SPACERS
COMMENT
Gives manufacturer, make and model description. Also lists voltage and amperage data.
ON when hood power switch is ON. Illuminates cooktop.
Container for Ansulex™ Low-pH liquid fire suppression liquid.
Allows the unit to be leveled.
Allows the unit to be easily positioned by lifting the front of the unit slightly.
Provides a means of manual activation of the fire suppression system. PULL ONLY IN CASE OF FIRE!
Designed to break at rated temperature. Breaking (i.e. fire on the cooktop) activates fire suppression system. Should be replaced at least once per year.
Allows access to Ansul® fire suppression agent tank (a6) and controls also access to main power contactor (41).
Fire suppression media discharges here (2 places).
Extracts and drains most grease and moisture from the air flow.
Comprises the PRE-FILTER FRAME and a replaceable PRE-FILTER. Stops larger particles of grease from reaching the FILTER PACK for reduced maintenance costs.
Stops most grease and smoke particles. Also assists in some cooking odor removal.
Collects grease/moisture dripping from grease baffle(16).
Exit point for ventilator airflow - on top left rear of unit.
DO NOT BLOCK
Displays status of fire suppression system (COCKED - FIRED) If FIRED, a buzzer will sound continuously.
6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).
Energizes cooking appliances only while ventilator section is sensed as operational.
Reports fire alarm condition to building fire management system.
Ground wire of power cord connects here.
Provides connection for shut-down control by building fire management system.
Proper installation of grease baffle and filter pack close these switches in ventilator sensor circuit.
Provides air movement for ventilation.
Required on left and right sides of hood. Factory installed.
Required to maintain 6" spacing from combustibles. Field installed.
3
FEATURES & OPERATING CONTROLS (continued)
Fig. 2 Ventilator Section Controls & Indicator Lights
GRIDDLE SECTION
G.04
G.05
G.06
H.04
H.05
G.02
G.01
G.03
HUMITROL
RACK
W.04
OPTIONAL
DRAWER WARMER
SECTION
H.02
DRAWER
INSERT PAN
H.01
RW-STYLE
RWT-STYLE
COOKTOP
CONTROLS
W.03
W.02
W.01
W.08
W.09
HOTPLATE
SECTION
W.05
W.06
W.06
H.06
H.03
W.07
M508 p/n 2M-304456 Owners Manual WV-2HG
Fig. 3 Griddle, Hotplate and Drawer Warmer Sections
4
FEATURES & OPERATING CONTROLS (continued)
ITEM
VENTILATOR SECTION CONTROLS
V.01
V.02
V.03
V.04*
V.05*
V.06*
* See PRECAUTIONS & GENERAL INFORMATION, pages 8 for special procedures regarding prefilters and filter packs.
DESCRIPTION
POWER SWITCH
POWER ON INDICATOR
CHECK FILTERS ALARM
INDICATOR
REPLACE PREFILTER ALARM INDICATOR
REPLACE FILTER PACK ALARM INDICATOR
SERVICE REQUIRED ALARM INDICATOR
COMMENT
Energizes BLOWER MOTOR. If, after 10 seconds, proper conditions are met, cooking appliances are energized. APPLIANCE LIGHT is ON when POWER SWITCH is ON.
GREEN. Glows when POWER switch is ON.
AMBER. Glows if one or more filters are out of position. Check all filters and baffles for proper installation.
AMBER. Glows when PREFILTER is approaching the end of its service life and must soon be replaced.
AMBER. Glows when FILTER PACK is approaching the end of its service life and must soon be replaced.
RED. Glows when PREFILTER and/or FILTER PACK has reached the end of its service life and is too loaded to allow sufficient air flow. Filter MUST be replaced. Appliance is SHUT DOWN until expended filters are replaced.
GRIDDLE SECTION
G.01
G.02
G.03
G.04
G.05
G.06
HOTPLATE SECTION
H.01
H.02
H.03
H.04
H.05
H.06
OPTIONAL DRAWER WARMER SECTION
W.01
W.02
W.03
W.04
W.05
W.06
M508 p/n 2M-304456 Owners Manual WV-2HG
W.07
W.08
W.09
GRIDDLE TEMPERATURE CONTROL
GRIDDLE HEAT INDICATOR
GREASE DRAWER
COOKING SURFACE
WASTE TROUGH
WASTE CHUTE
TEMPERATURE CONTROLS
POWER INDICATOR
SOLID HEATING ELEMENTS
SPIRAL HEATING ELEMENT
TRIM RING
DRIP PAN
WARMER TEMP CONTROL
POWER ON INDICATOR
THERMOMETER (optional)
HUMIDITY CONTROL
DRAWER CATCH
DRAWER STOP
DRAWER ROLLERS
POWER SWITCH (RWT)
CONTROLLER (RWT)
Thermostatic control of griddle temperature
Glows when heating elements are energized.
Collects cooking waste from GRIDDLE. Removable for cleaning.
Heated portion for cooking food.
Scrape cooking waste to this area.
Cooking waste moved into GREASE DRAWER thru this opening.
Individual infinite switch control of the hotplate HEATING ELEMENTS
Glows anytime the TEMPERATURE CONTROL is in any position other than OFF.
WV2HG heating/cooking portion. Element is fixed in position.
WV2SHG heating/cooking portion. Element lifts out for cleaning.
Mounts element to cabinet.
Catches drippings and crumbs (spiral element only). Removable for cleaning.
Infinite switch control of temperature of one warmer drawer.
AMBER. Glows when associated temperature control is turned ON.
Reads temperature inside drawer cavity Must be ordered at time of initial build.
Slide control of shutters to control air circulation within the warmer drawer.
Holds drawer closed.
Prevents drawer from opening too far. Spring loaded to permit easy removal of drawer.
Support drawer and allow it to open and close smoothly.
Energizes unit (RWT-style only)
Controls cavity temperature. Readout displays setpoint and actual temperature information. UP ARROW / DOWN ARROW keys allow modification of setpoint temperature. (RWT-style units only)
5
PRECAUTIONS AND GENERAL INFORMATION
DANGER
FIRE HAZARD
THE FIRE SUPPRESSION
SYSTEM MUST BE CHARGED AND CERTIFIED BY AN AUTHORIZED
ANSUL® DISTRIBUTOR. NEVER ATTEMPT TO
MODIFY OR BYPASS THE FIRE SUPPRESSION SYSTEM. AN UNCONTROLLED FIRE CAN CAUSE SERIOUS INJURY, DEATH AND/OR PROPERTY LOSS.
WARNING:
ELECTRIC
SHOCK HAZARD
All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel which requires the use of tools. Failure to follow this warning can result in severe electrical shock.
NOTE: Fire suppression system and all associated components must only be serviced by an authorized Ansul® Distributor. All setup, charging, repair and/or adjustment of the fire suppression system must be performed by an Authorized Ansul® Distributor ONLY.
IMPORTANT: If a remote pull station is installed, both rear casters (9) must be replaced with legs to deter moving the unit. MOVING AN APPLIANCE WITH A REMOTE PULL STATION WILL DISCHARGE THE FIRE SUPPRESSION SYSTEM.
This Ventless Cooking System™ is designed to help reduce odor emissions, but will not completely eliminate cooking odors. Air exchange at the installation site must comply with the requirements of the local jurisdictional authority. To ensure that odors do not build-up, recommended minimum air exchange is 300 - 400 cfm of outside air into and out of the area where the unit is used. Recommend use of wall fan and wall switch, to be supplied by user.
Disconnect this appliance from electrical power before performing any maintenance or servicing.
Any procedure which requires the use of tools must be performed by a qualified technician.
This appliance is not jet stream approved. Do not direct water jet or steam jet at this appliance, or at any control panel or wiring.
Do not splash or pour water on, in or over any exposed element, control, control panel or wiring.
The surface of the griddle is very hot during operation and can cause severe burns. Avoid contact with the hot griddle surface.
Exposed surfaces of this appliance can be hot to the touch and may cause burns.
M508 p/n 2M-304456 Owners Manual WV-2HG
6
PRECAUTIONS AND GENERAL INFORMATION (continued)
This appliance is intended for use in commercial establishments only.
This appliance is intended No other use is agents.
recommended or authorized by the manufacturer or its
to prepare food for human consumption.
Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation. Read and follow all included cleaning instructions and schedules to ensure the safety of the food product.
DO NOT submerge pre-filter or filter pack in water. Water will destroy the filters leading to equipment shut-down.
Use only genuine Wells replacement parts and filters, call (314) 678­6314 or your authorized Wells service agent. Parts supplied by others will void your warranty and may not provide safe operation.
The technical content of this manual, including any wiring diagrams, schematics, parts breakdown illustrations and/or adjustment procedures, is intended for use by qualified technical personnel.
This manual is considered to be a permanent part of the appliance. This manual and all supplied instructions, diagrams, schematics, parts breakdown illustrations, notices and labels must remain with the appliance if it is sold or moved to another location.
This appliance is made in the USA. Unless otherwise noted, this appliance has American sizes on all hardware.
CAUTION:
RISK OF DAMAGE
DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.
CAUTION:
HOT SURFACE
Exposed surfaces can be hot to the touch and may cause burns.
M508 p/n 2M-304456 Owners Manual WV-2HG
7
PRECAUTIONS AND GENERAL INFORMATION (continued)
Fig. 4 Ventilator Warning Indicators
OPERATIONAL NOTES:
REPLACE PREFILTER and REPLACE FILTER PACK indicator lights provide a timely warning that a system shut-down is imminent.
The actual time between the indicator light coming on and the loss of cooking appliance power will depend upon the cooking conditions.
Anytime a dirty PRE-FILTER is replaced, the system airflow will increase. If the condition of the FILTER PACK is marginal, the REPLACE FILTER PACK light could then come on. If this happens, a fresh FILTER PACK must be installed within a reasonably short time.
Loss of airflow through the old filter pack will soon cause a system shut-down when the airflow falls below minimum vapor capture levels.
KEEP SPARE FILTER PACKS ON HAND.
IMPORTANT: If you decide to “get the most” out of the old filter pack, and continue to use it until a system shut-down happens, it is advisable to have a fresh filter pack readily at hand, and have someone available who is capable of replacing it. Otherwise, you may experience an extended down time, with consequent associated loss of business.
The manufacturer assumes no liability for loss of business due to a system shutdown caused by a dirty pre-filter and/or filter pack (i.e. red SERVICE REQUIRED light is on), when the user fails to have the proper replacement pre-filter and/or filter pack on hand.
The Ventless Cooking System™ hood is designed as part of a WELLS cooking appliance only. No other use of this product is authorized by
the manufacturer or its agents. Wells Mfg. assumes no liability for the use of this equipment with products by any other manufacturer’s, or for use of this equipment with any Wells Manufacturing product other than in factory certified applications.
AGENCY LISTING INFORMATION
This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation Instructions
STD 4
E146882
E146882
And operated and maintained in accordance with the instructions in this manual. This appliance is and Listed under UL File E146882.
M508 p/n 2M-304456 Owners Manual WV-2HG
8
INSTALLATION
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the Appliance before connecting electrical power or otherwise performing any installation procedure.
Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.
Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding packing materials. Store these components in or near the appliance for later use. These items must be installed before operating the appliance.
1 ea. FIRE SUPPRESSION AGENT (ANSULEX® Low pH, 1.5 GAL.) See Material Safety Data Sheet, page 28. 1 ea. FIRE SUPPRESSION MEDIA TANK 1 ea. FIRE SUPPRESSION TANK CHARGING CARTRIDGE 1 ea. GREASE BAFFLE 1 ea. FILTER PACK ASSEMBLY 1 ea. PRE-FILTER HOLDER with PRE-FILTER 1 ea. GREASE DRIP TRAY 1 ea. GREASE DRAWER ASSY FOR GRIDDLE 2 ea. 6” SIDE SPACERS 1 ea. LITERATURE PACKAGE Additionally: 2 ea. DRAWER PANS (if unit has optional drawer warmers) 2 ea. HUMITROL RACKS (if ordered with warmer drawers)
SETUP
Setup the appliance only on a firm level surface. Non-combustible material is recommended.
Refer to the Installation Instruction Sheet for required clearances. Maintain required clearances between the appliance and adjacent combustible surfaces. Verify 6” left and right side clearances to combustible construction. This appliance requires a minimum of 8 ft (96”) (floor to overhead) to allow for adequate exhaust.
IMPORTANT: Provided 6" side spacers (item 58) must be installed on the appliance.
Factory installed side shields (item 57) are required.
Verify that the VENTILATOR HOOD ASSEMBLY is properly and securely assembled to the cooking appliance before beginning the
M508 p/n 2M-304456 Owners Manual WV-2HG
installation procedure.
If a remote manual pull station is to be installed, replace the rear casters with legs.
Level the unit after it is in its final position. Using a spirit level, verify that the unit is level front-to-back and side-to-side.
NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.
WARNING:
RISK OF
Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical codes. Failure can result in personal injury and property damage.
INJURY
WARNING:
FIRE HAZARD
Avoid storing flammable or combustible materials near the appliance.
9
INSTALLATION (continued)
IMPORTANT!
Verify that this VENTILATOR and food cooking equipment installation is in compliance with the specifications listed in this manual, with local code requirements, and in accordance with N.F.P.A 96 (THE STANDARD FOR
VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING OPERATIONS -
current edition).
THIS IS THE
RESPONSIBILITY
OF THE INSTALLER
DANGER
ELECTRIC SHOCK
ELECTRIC CONNECTIONS MUST BE MADE BY A LICENSED ELECTRICIAN Electrical shock will cause death or serious injury.
HAZARD
CAUTION:
ELECTRICAL
The ground lug of this appliance must be connected to a suitable building ground. NOTE: This appliance requires a dedicated 60 Amp electrical branch circuit protection.
IMPORTANT:
Contact a licensed electrician to install and connect electrical power to the appliance.
IMPORTANT:
Damage due to being connected to the wrong voltage or phase is NOT covered by warranty.
SHOCK HAZARD
SERVICE TECHNICIAN INSTALLATION NOTES
An Ansul® technician must charge and arm the fire suppression system before the ventilator blower will operate. See page 11.
Installation and start up must be performed by an Authorized Installation Company.
Installer must complete the WARRANTY REGISTRATION form, and record appliance installation particulars on the CUSTOMER SERVICE DATA form in this manual.
Certain codes require cooking equipment to be restrained with a RESTRAINT DEVICE. It is the RESPONSIBILITY OF THE INSTALLER to check with the AUTHORITY HAVING JURISDICTION, in order to ascertain the applicability of this requirement to THIS SPECIFIC EQUIPMENT INSTALLATION. Any restraint device must allow access to the back and sides of the unit to provide for servicing and maintenance, and must not interfere with the operation of the FIRE SUPPRESSION SYSTEM.
ELECTRICAL INSTALLATION
1. This appliance must be installed by a licensed electrician in accordance with all applicable codes and ordinances. Electrical connection terminal block and ground lug are accessible by removing the right side panel.
2. Refer to the nameplate on the right side of the appliance. Verify the ELECTRICAL SERVICE POWER. Voltage and phase must match the nameplate specifications, and available electrical service amperage must meet or exceed the specifications listed on page 1. Wiring must be no less than 6 AWG solid copper wire, rated for at least 90ºC.
NOTE: Wire gauge, insulation type and temperature rating , as well as type, size and construction of conduit, must meet or exceed applicable specifications of local codes and of the National Electrical Code.
NOTE: This appliance requires a NEMA 15-60R receptacle.
3. This appliance must be connected to a suitable building ground. The equipment ground connection is marked " ".
4. The appliance is shipped from the factory wired for 3Ø electrical service. Refer to the Wiring Diagram included with this appliance, and verify that field wiring conforms to this diagram.
IMPORTANT: This appliance is not approved for 1Ø operation. Conversion of this appliance to single-phase operation will void the warranty.
M508 p/n 2M-304456 Owners Manual WV-2HG
10
Loading...
+ 28 hidden pages