Wells Manufacturing 6423 Service Manual

2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
WELLS BLOOMFIELD, LLC
telephone: 775-689-5707
fax: 775-689-5976
www.wellsbloomfield.com
010
INSTALLATION INSTRUCTIONS
KIT# 506863
Element bracket kit# 506863 positions heating elements in 12x20 pan-style warmers.
This kit replaces obsolete clips p/n 50397 and 50467.
PREPARATION
Disconnect unit from electric power.
Disassemble element pan from warmer.
Remove and discard all existing element clips.
On end panel away from element terminals, mark a line
1/2” (12.7mm) from top edge of panel. Locate and mark the center of the panel.
On end panel nearest element terminals, mark a line 5/32” (4mm) above centerline of element “keyhole” cutouts. Locate and mark the center of the panel.
Bend retaining tabs on brackets no more than 45º. Each bracket has 2 tabs.
ASSEMBLY
Attach the “U” shaped bracket to end panel away from element terminals:
a. Center bracket on panel with the two bracket mounting holes aligned with the 1/2” line. b. Mark the location of the bracket mounting holes Drill a 1/16” diameter hole at each location. c. Attach bracket to INSIDE of pan with provided drill-point screws.
Attach “I” shaped bracket to end panel nearest element terminals:
a. Drill a 1/16” diameter hole at the at the intersection of the centerline and the 5/32” line. b. Attach bracket to INSIDE of pan with provided drill-point screws.
Install element on bracket.
Bend retaining tabs to capture element.
NOTE: Brackets locate element the proper distance from bottom of
pan, but allow element to expand and contract during heating cycle. Be sure element is free to move laterally in bracket.
Reassemble warmer and return to service.
CAUTION:
FIRE HAZARD
Disconnect from electric power before servicing appliance.
CAUTION:
BURN HAZARD
Allow appliance to cool completely before servicing.
Bend retaining tabs no more than 45º.
“U” SHAPED BRACKET (REAR)
CENTERED
45º
CENTERED
“I” SHAPED BRACKET (FRONT)
p/n 306864 Rev. A ECN-13360 I 010 071024 cps
Page 1 of 1