Wells-Gardner D9300 User Manual

Wells-Gardner Electronics Corporation
Service Manual for
D9300 Series
Digital-Control Color Monitor
Wells-Gardner Electronics
th
5500W. 55
Street Suite A
(708) 290-2100
Date: 8-18-00
069X3045-100
ECN: E01024
Printed on 03/20/03
Wells-Gardner Electronics Corporation
INDEX
1. SAFETY PRECAUTION……………………………… 1
2. SPECIFICATION……………………………………… 2
3. TECHNCIAL FEATURES……………………………. 3
4. TIMING CHART………………………………………. 4
5. SET UP………………………………………………….. 6
6. CONTROLS AND ADJUSTMENT…………………... 7
7. ADJUSTMENT SPECIFICATION……………………12
8. DESCRIPTION OF CIRCUIT OPERATION………...17
9. TROUBLE SHOOTING………………………………..21
ii
Wells-Gardner Electronics Corporation
1. SAFETY PRECAUTION:
WARNING: Service should not be attempted by anyone unfamiliar with the necessary
precautions on this unit. The following precautions are necessary during servicing.
1-1 Some parts, such as a picture tube in this unit, have special safety-related characteristics
for X-RAY RADIATION protection. For continued safety, the parts replacement should be undertaken referring to below article (1-2 and 1-5).
1-2 Many electrical mechanical parts in this unit have special safety-related characteristics for
protection against shock hazard and others. These characteristics are often passed unnoticed by visual inspection and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special characteristics are identified in the manual and supplements by shading on the schematic diagram and the parts list. Before replacing any of these components, read the parts list in this manual carefully.
1-3 When replacing the chassis in the cabinet, always be certain that all the protective devices
are installed properly, such as insulating covers, strain relief, etc.
1-4 Before replacing the back cover of the set, thoroughly inspect the inside of the cabinet to
see that no stray parts or tools have been left inside.
1-5 Before returning the set to the customer, always perform an AC leakage current check on
the exposed metallic parts of the cabinet, such as terminal, screwheads, metal overlays, control shafts, etc. To insure the set is safe to operate without danger of electrical shock, plug the AC line cord directly into a 120V AC outlet (do not use a line isolation transformer during this check). Use an AC voltmeter having 5000 ohms per volt or more sensitivity in the following manner. Connect a 1500 ohm, 10 watt resistor, parallel with a (0.15uF) capacitor. Reverse the AC plug in the AC outlet and repeat the AC voltage measurements for each exposed metallic part. Voltage measured must not exceed 0.3V RMS. This corresponds to 0.2mA AC, any value exceeding this limit constitutes a potential shock hazard and must be corrected immediately.
1
Wells-Gardner Electronics Corporation
2. SPECIFICATION:
2-1 Picture Tube.
x Size: 18V x Dot Pitch: .25mm
2-2 Signal Input.
x Video Input: Analog, Positive Signal (0.7V p-p) x Horizontal Sync: TTL Level, Positive or Negative Pulse x Scanning : 28 KHz-70KHz x Vertical Input: TTL Level, Positive or Negative pulse x Scanning : 40-160Hz
2-3 Power Supply.
x Power Input : 120-240 VAC, 50/60Hz x Fuse Rating: 250V, 3.15A x Power Consumption
Normal : less than 130W
2-4 OSD (On Screen Display) Control:
Refer to page 7
2-5 Operating Temperature: 0qC - 55qC
2-6 Operating Humidity: 10% - 90% (Noncondensing)
2-7 Net Weight : 17kg (37lbs)
2
Wells-Gardner Electronics Corporation
3. TECHNICAL FEATURES:
3-1 Microprocessor control with OSD (On screen display menu).
Microprocessor recognizes the input computer signal and signal output from the customer control board connected to the main board by a flat cable.
3-2 Universal AC Input Voltage.
Power supply operates on 120-240 VAC at 60/50Hz for use all over the world.
3-3. Protection Circuit for over-current.
When an over-current condition occurs in the circuit, the protection circuit operates in order to prevent the components from electrical shock or other risks.
3-4 Override function.
A (NO SIGNAL MESSAGE) is displayed on the screen if no signal is present at the signal input cable while the monitor is powered on.
3-5 Control panel.
If you require different display characteristics other than the factory mode presets of size, position, color settings, use the control panel to program it to your requirements in each resolution mode. These adjusted settings are kept in memory even if you change resolution mode or turn off the monitor.
3-6 I²C BUS control.
The monitor is designed with I²C BUS control for simplifying the circuitry. The number of total components is less than 610 pcs.
3
Wells-Gardner Electronics Corporation
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
X
4. TIMING CHART:
Factory Pre-Set Timing Modes. Horizontal and Vertical Timing Diagram for Table 1
.
QUANTUM 801G
FORMAT
DESCRIPTION
HC
POL.
VC
POL.
VIDEO
FH
A B
D E
FV
A B
D E
TABLE 1 :
MVP-NSW US500 MK6
MODE 1 MODE 2 MODE 3 MODE 4
640*400 640*400 640*480 8514/A 1024*768
29.63Hz 31.5KHz 31.35KHz 35.552KHz
33.75
26.67
POSITIVE POSITIVE POSITIVE POSITIVE
62.91Hz 70.1Hz 59.8Hz 86.960Hz
15.88ms 14.2ms 16.72ms 11.500ms
0.0338ms 0.0636ms 0.066ms 0.113ms
1.680ms 1.110ms 1.052ms 0.563ms
13.56ms 12.7ms 15.36ms 10.810ms
0.675ms 0.408ms 0.316ms 0.014ms
POSITIVE
ANALOG
1.76
3.52
1.86
s s s
s s
31.778
1.84
25.4
0.63
POSITIVE POSITIVE
ANALOG
s
s3.86
3.88
s s s
28.251
2.04
25.5
0.58
ANALOG ANALOG
s s s s s
VGA_M4
28.251
3.920
1.247
22.806
0.170
POSITIVE
s s s
s s
4
Wells-Gardner Electronics Corporation
A
V
A
V
V
A
C
V
A
V
V
µ
µ
µ
µ
µ
V
µ
V
V
V
V
V
µ
µ
µ
µ
µ
µ
A
µ
µ
µ
µ
µ
A
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
µ
V
µ
µ
V
µ
µ
A
A
V
µ
µ
µ
µ
QUANTUM 801GX
FORMAT
DESCRIPTION
FH 37.500KHz
B 2.032us
H C 3.810us
D 20.317us E 0.508us
POL.
F
B 0.080ms C .427ms D 12.800ms E 0.027ms
POL.
IDEO
QUANTUM 801GX
FORMAT
DESCRIPTION
FH
B
H
D E
POL.
F
B C D E
POL.
IDEO
MODE 5, S-VG
26.667us
75.00Hz
13.333ms
VG900602 DMT8075
ESA 680*480
NEGETIVE
NEGETIVE
ANALOG
DMT8085
MODE 10
ESA 800*600
53.674KHz
18.631
1.138
2.702
14.222
0.569
POSITIVE NEGATIVE POSITIVE
85.062Hz 70.069Hz
11.756ms 14.272ms 13.328ms
0.056ms 0.106ms 0.050ms
0.503ms
11.179ms
0.019ms
POSITIVE
ANALOG
s s1.813 s1.920
s13.653 s0.321
VGA 800*600
37.879KHz
26.400
3.200
2.200
20.000
1.000
POSITIVE
60.317Hz
16.579ms
0.106ms
0.607ms
15.840ms
0.026ms
POSITIVE
ANALOG ANALOG
VS910801 DMT1075 DMT1260 DMT1085
MODE 11
ESA 1024*768
56.476KHz
17.707
0.513ms 0.466ms
13.599ms
0.054ms
NEGATIVE
ANALOG
s s s
s s
s 16.660µs s1.219 s2.235
s 13.003µs s0.203
VS900603
ESA 800*600
46.875KHz 48.077KHz
21.333
1.616
3.232
16.162
0.323
POSITIVE
75.000Hz
13.333ms
0.064ms
0.448ms
12.800ms
0.021ms
POSITIVE
MODE 12
ESA 1024*768
60.023KHz
75.029Hz
12.795ms
0.017ms
POSITIVE
ANALOG
VG901101
MODE 8MODE 6 MODE 7 VG
ESA 800*600
s s s
s s
s s
s
20.800
2.400
1.280
16.000
1.119
POSIIVE
72.188Hz
13.853ms
0.125ms
0.478ms
12.480ms
0.722ms
POSITIVE
MODE 13
ESA 1280*1024
63.981KHz
15.698
1.037
2.296
11.852
0.360
POSITIVE
60.020Hz
16.638ms
0.047ms
0.594ms
16.005ms
0.016ms
POSITIVE
s s s
s s
NALOG
s s s
s s
NALOG
VG901101
MODE 9
ESA 1024*768
48.363KHz
20.677
2.231
1.615
15.754
0.998
NEGATIVE
60.004Hz
16.666ms
0.124ms
0.600ms
15.880ms
0.062ms
NEGATIVE
ANALOG
MODE 14
ESA 1024*768
68.677KHz
14.561
1.016
2.201
10.836
0.508
POSITIVE
84.997Hz
11.765ms
0.044ms
0.524ms
11.183ms
0.015ms
POSITIVE
ANALOG
s s s
s s
s s s
s s
5
Wells-Gardner Electronics Corporation
5. SET UP:
Setting up your monitor is easy. All you have to do is make a few simple connections and adjustments. The procedure is as follows:
5.1 Start Up.
Your monitor starts up automatically when you insert the power plug to power source.
5-2. Single Cable Connection.
Connect the 15pin signal cable to the source and lock both screws to ensure that the monitor is properly grounded.
D type 15pin connector:
PIN NO. DESCRIPTION PIN NO. DESCRIPTION
1 VIDEO RED 9 N.C. 2 VIDEO GREEN 10 GROUND 3 VIDEO BLUE 11 N.C. 4 N.C. 12 SDA 5 N.C. 13 HOR-SYNC 6 VIDEO RED GROUND 14 VER-SYNC 7 VIDEO GREEN GROUND 15 SCL 8 VIDEO BLUE GROUND
6
Wells-Gardner Electronics Corporation
6. CONTROLS AND ADJUSTMENTS:
There are four switches on the control panel. Adjustable controls allow the best display status for individual requirements.
6-1. Key Function.
1. MODE/EXIT MODE – Call the Main-Menu OSD
2. SEL / Degauss SEL – Call the Sub-Menu OSD
Degauss – Degausses the CRT (active when the OSD is not displayed)
3. DOWN/UP When the Main-Menu is displayed, you can select each function using these keys.
When the Sub-Menu is displayed, you can change the amplitude of the selected function of the screen using these keys.
6-2. O.S.D. CONTROL METHOD.
User Adjustment.
Location Adjustment Method Function
Brightness Contrast
Horizontal Position CUSTOMER CONTROL PCB OSD CONTROL
VR control, VR501
MAIN PCB
*NOTE: (FACTORY ADJUSTED AND EPOXYED VR301)
(HOT MELTED SCREEN FBT)
VR301 FBT VR302
7
Horizontal Size
Vertical Position
Vertical Size
Side Pincushion
Trapezoid
Pin Balance
Parallelogram
Sub-Bright
H.V. Adjustment*
Focus and Screen
Tilt
Loading...
+ 19 hidden pages