The ventless hood gives you the flexibility to “set up shop” just about anywhere from malls, stadiums and high-rise buildings to basement kitchens and kiosks.
Griddle (All Models)
• Griddle surface (17 1/4”W x 18 1/4”D) has enclosed tubular heat distribution.
• Griddle is controlled by a positive-off thermostat adjustable from 100ºF to 400ºF.
• Griddle features include a full-width front grease
trough, an extra-large removable front grease drawer and a stainless steel splashguard.
elements that provide even
VENTLESS GRIDDLE/FRYER/COOKTOPS
WV-FGRW
Ventless Hood (All Models)
• Ventless Hood System exceeds EPA Standard 202 for the release of particulate matter.
Interlock System will not allow heating elements to be energized if any of the filters are not in place.
Airflow Sensing System continually monitors airflow through the filtration system, optimizing performance and grease removal.
Ansul is built into the ventless hood to provide ultimate protection.
Shatter-resistent interior light for improved visibility.
®
R-102 Fire Suppression System
Fryer (WV-FG, WV-FGRW)
Two half-size, rear hanging, interchangeable fry baskets are provided.
Efficient heating element is flat, heavy-duty stainless steel.
• Fryer on/off switch is located in recessed front control panel.
The positive-off thermostat controls the element consistent temperatures.
The fryer has a manual reset safety thermostat that will shut off the heating element if an over-temperature condition is reached.
• Model WV-FGRW includes a Wells RW-26 built-in standard double drawer warmer that replaces lower storage cabinet.
allowing for adjustable and more
Cooktop (WV-2HG, WV-2HSG, WV-2HGRW, WV-2HSGRW)
• Model WV-2HG has two solid cast iron 9" french plate elements that are independently regulated by
an infinite control with a positive-off position.
• Model WV-2HSG has two spiral 8" elements that are independently regulated by an infinite control with a positive-off position.
• Models WV-2HGRW and WV-2HSGRW include a
Wells RW-26 built-in standard double drawer warmer that replaces lower storage cabinet.
COOKING SURFACE ILLUSTRATION
8 INCH SPIRAL ELEMENTS
GRIDDLE: 17 1/4 X 18 1/4
AND PLUG
SUPPLY CORD
6 FT. POWER
OPENING
PANEL
CONTROL
SHIELDS
SPACERS & SIDE
6" CLEARANCE
REQUIRED
(441)
17 3/8
577
22 3/4
1076
42 3/8
688
27 1/16
(2010)
79 1/8
(771)
30 3/8
(898)
35 3/8
(914)
36
1217
47 15/16
EXHAUST
AIR
E146882
LISTED
R
LISTED
R
E146882
R
STD.4
W E L L S M A N U F A C T U R I N G
(1237)
48 11/16
(441)
17 3/8
(1076)
42 3/8
(898)
35 3/8
(578)
22 3/4
(2010)
79 1/8
(914)
36
(771)
30 3/8
(687)
27 1/16
(533)
21
PANEL
CONTROL
OPENING
EXHAUST
AIR
SHIELDS
SPACERS & SIDE
6" CLEARANCE
REQUIRED
AND PLUG
SUPPLY CORD
6 FT. POWER
COOKING SURFACE ILLUSTRATION
GRIDDLE: 17 1/4 X 18 1/4
FRYER
E146882
LISTED
R
LISTED
R
E146882
R
STD.4
M O D E L
W V - F G
G R I D D L E , F R Y E R
D I M E N S I O N S :
INCH
(MM)
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
BACK SIDE BOTTOM TOP NA NA
SEE REQUIRED 6 8
SPACERS (152) (203)
W V - F G E L E C T R I C A L S P E C I F I C AT I O N S :
MODELS VOLTS WATTS
AMPS PER LINE 3 PHASE
L1 L2 L3
POWER SUPPLY CORD
WV-FG 208 10750 30 43 24 NEMA 15-60P
WV-FG 240 11650 26 40 24 NEMA 15-60P
WV-FGRW* 208 11425 32 43 26 NEMA 15-60P
WV-FGRW* 240 12550 28 40 27 NEMA 15-60P