Wells WB-1 Service Manual

WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5703
fax: 775-689-5976
www.wellsbloomfield.com
SERVICE BULLETIN
108.001
TO: Wells Service Agencies February 12, 2008 FROM: Tony Nixon, National Service Manage r SUBJECT: Revised Temperature Control and Heating Elements in WB-Series Waffle Bakers
WB-1 and WB-2 waffle bakers maufactured after Jan 1, 2008 use a solid state system for temperature control. Also, heating elements have been configured to conform to the latest UL requirements.
UPPER GRID
WIRE SET, TOP GRID
LOWER GRID
CABINET
Components Involved in Waffle Baker Revision
507281
ELEMENT, HEATING 120V 450W (INCL. INSULATORS) 507277
PROBE, TEMPERATURE 507279
WIRE SET, BOTTOM GRID 507282
ADAPTER, COUPLING 1/4X 1/4M PUSH-ON (208-240V ONLY) 50407
ADAPTER, TERM 1/4F x TWIN 1/4M (120V ONLY) 507355
CONTROLLER, TEMPERATURE 507278
BRACKET, CONTROL MOUNT 507482
REAR PANEL, WB-1 507478 ASSY, HOLE PLUG 61064
REAR PANEL, WB-2 507479
ASSY, HOLE PLUG 61064
NOTE:
Detailed servicing information is included in the service manual
Supplemental Servicing Instructions for Waffle Bakers Model WB-1 and WB-2
(p/n 507573).*
Kits #507582 and #507584 retrofit existing mechanical thermostat units to the new solid state temperature control.
Kit #507582 will retrofit a single WB-1
Kit # 507584 will retrofit one side of a WB-2
Upgraded elements are available individually as p/n 507277. Elements include new insulators and terminal screws.
IMPORTANT: Use only the included terminal screws. DO NOT attempt to use substitute screws to connect power leads to the new elements.
NOTE:
Upgraded heating elements are only necessary in the event of element failure. UL listing remains valid for equipment manufactured prior to Jan. 1, 2008. However, old-style elements are no longer available as replacement parts.
* Wells Service Manuals available at EM-Web. http://www.4emweb.com login = wbvisitor password = wbvisit
SvcB 108.001 080212 cps
1 of 1
Loading...