INSTALLATION INSTRUCTIONS
PART # 51878
POTS WITH CENTER-STUD
Kit #51878 replaces all element pans used on Wells round built-in warmer models SS-4, SS-8 and SS-10.
An ADAPTER is provided for use on older style non-drain pots with center stud. To mount this element pan to pots with center-stud:
PREPARATION:
1. Disconnect appliance from electric power and allow to cool.
2. Disconnect electric supply from element. Remove and save electrical inlet box.
3. Disconnect and save thermobulb and clips (if used).
4.
5. Remove existing element pan.
INSTALLATION:
1. Attach adapter to bottom of new element pan with the provided screws and nuts. Center hole of adapter must be in the center of the large hole in the element pan.
NOTE: Discard adapter when installing element pan on pots with a drain, and on pots without a center stud.
2. Seat element in element bracket. Install element and bracket in element pan.
3. Reinstall thermobulb and clips (if used).
4. Install element assembly on bottom of pot. The flat face of the element must be toward the bottom of the pot.
5. Reattach electrical outlet box. Reconnect wiring.
6. Reconnect appliance to electrical power. Test for proper operation.
CAUTION:
SHOCK HAZARD
Disconnect appliance from electric power before opening any access panel.
CAUTION:
BURN HAZARD
Allow appliance to cool completely before servicing.
STUD NUT
ADAPTER NUT (2 pl)
ADAPTER
THERMOBULB CLIP (3 pl when used)
ELEMENT PAN
ELEMENT BRACKET
ADAPTER SCREW (2 pl)
ELEMENT
POT STUD
Fig. 1 Element Pan Installation