Wells RWN-36 Installation Manual

ELECTRICAL
RWN-36 RWN-36
ALL MODELS WITH A 'T' SUFFIX HAVE THE SAME ELECTRICAL SPECIFICATIONS AS THE STANDARD VERSIONS.
FRONT PANEL CUTOUT
208 240RWN-36
19 1/8
(486)
1350120 1014 1350
30 1/8
(765)
11.3
4.9
SINGLE SINGLE5.6
15
(381)
20 1/4
(514)
FIELD WIRINGPHASEAMPSWATTSVOLTSMODEL GAUGE
14 AWB CuSINGLE 14 AWB CU
PRODUCT DIMENSIONSCUTOUT DETAILS
5 5/8 (143)
TEMP.
RATING
26 1/2
(673)
90°C 90°C 90°C14 AWB Cu
INSTALLATION INSTRUCTIONS
BUILT-IN NARROW DRAWER WARMERS
MODELS RWN-36 (T)
INCHES
(MM)
19 5/8
(498)
CLEARANCES
THERE ARE NO CLEARANCE REQUIREMENTS FOR THIS UNIT.
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY OUTLINED BELOW UPON INSTALLATION:
TO FABRICATE:
1. Layout front panel cutout dimensions and cutout hole in counter front panel.
2. Position attaching flange (supplied) in hole cutout to determine screw hole location. Drill holes using #34 drill.
3. Attach flange to front panel using #6 screws provided.
1. For ease of installation, remove drawers from unit.
2. Slide unit through front panel opening until rear of unit engages rear support.
3. Remove upper control knob and upper control panel.
4. Install #8-32 speednuts on attaching flange, secure attaching flange to front panel, then secure unit to attaching flange using #8-32 flathead screws provided.
5. Connect service leads to the unit including ground wire.
6. Replace control panel and control knob.
7. Replace drawer.
31 1/8
(791)
26 1/2
(673)
RAILS FLUSH TO BOTTOM OF CUTOUT
REAR SUPPORT
FROM OUTSIDES OF RAILS
15
(381)
REAR SUPPORT
29 3/4
(756)
WELLS/BLOOMFIELD * VERDI, NV
49340-3 REV (-)
Loading...