ELECTRICAL
RWN-36
RWN-36
ALL MODELS WITH A 'T' SUFFIX HAVE THE SAME ELECTRICAL
SPECIFICATIONS AS THE STANDARD VERSIONS.
FRONT PANEL CUTOUT
208
240RWN-36
19 1/8
(486)
1350120
1014
1350
30 1/8
(765)
11.3
4.9
SINGLE
SINGLE5.6
15
(381)
20 1/4
(514)
FIELD
WIRINGPHASEAMPSWATTSVOLTSMODEL
GAUGE
14 AWB CuSINGLE
14 AWB CU
PRODUCT DIMENSIONSCUTOUT DETAILS
5 5/8
(143)
TEMP.
RATING
26 1/2
(673)
90°C
90°C
90°C14 AWB Cu
INSTALLATION INSTRUCTIONS
BUILT-IN NARROW DRAWER WARMERS
MODELS RWN-36 (T)
INCHES
(MM)
19 5/8
(498)
CLEARANCES
THERE ARE NO CLEARANCE REQUIREMENTS FOR THIS UNIT.
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
TO FABRICATE:
1. Layout front panel cutout dimensions and cutout hole
in counter front panel.
2. Position attaching flange (supplied) in hole cutout to
determine screw hole location. Drill holes using #34 drill.
3. Attach flange to front panel using #6 screws provided.
4. Fabricate rails and rear support in locations shown.
TO INSTALL:
1. For ease of installation, remove drawers from unit.
2. Slide unit through front panel opening until rear of
unit engages rear support.
3. Remove upper control knob and upper control panel.
4. Install #8-32 speednuts on attaching flange, secure
attaching flange to front panel, then secure unit to
attaching flange using #8-32 flathead screws provided.
5. Connect service leads to the unit including ground wire.
6. Replace control panel and control knob.
7. Replace drawer.
31 1/8
(791)
26 1/2
(673)
RAILS
FLUSH TO
BOTTOM OF
CUTOUT
REAR SUPPORT
FROM OUTSIDES
OF RAILS
15
(381)
REAR
SUPPORT
29 3/4
(756)
WELLS/BLOOMFIELD * VERDI, NV
49340-3 REV (-)