Wells HDG-2430G, HDG-4830G, HDG-3630G User Manual

Page 1
Model HDG-3630G
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5703
fax: 775-689-5976
www.wellsbloomfield.com
OPERATION MANUAL
HEAVY DUTY
GAS GRIDDLE
MODELS
HDG-2430G HDG-3630G HDG-4830G
INSTALLATION
USE & CARE
122
Includes
FOR YOUR SAFETY
Do not store gasoline or other flammable liquids
in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and mainte­nance instructions thoroughly before installing or servicing this equipment.
IMPORTANT:
The purchaser of this equipment must post in a prominent location instructions to be followed in the event the user smells gas. This information shall be obtained by consulting the local gas supplier.
IMPORTANT: DO NOT DISCARD THIS MANUAL
This manual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS U S ING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
PRINTED IN CHINA
p/n 306626 Rev. B ECN-13352 M122 071018 cps
Page 2
ENGLISH
Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser only. THIS WARRANTY IS THE COMPLETE AND ONLY WARRANTY, EXPRESSED OR IMPLIED IN LAW OR IN FACT, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND/OR FOR DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH WELLS BLOOMFIELD PRODUCTS. This warranty is void if it is determined that, upon inspection by an authorized service agency, the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God. It also does not apply if the serial nameplate has been removed, or if service is performed by unauthorized personnel. The prices charged by Wells Bloomfield for its products are
SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS
LIMITED WARRANTY STATEMENT
based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Wells Bloomfield factory authorized service agency or one of its sub-service agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest authorized service agency, transportation charges prepaid, for service. In addition to restrictions contained in this warranty, specific limitations are shown in the Service Policy and Procedure Guide. Wells Bloomfield authorized service agencies are located in principal cities. This warranty is valid in the United States and Canada and void elsewhere. Please consult your classified telephone directory, your foodservice equipment dealer or contact:
Service Department, Wells Bloomfield, LLC
P.O. Box 280, Verdi, Nevada 89439
phone (775) 689-5707 or fax (775) 689-5976
for information and other details concerning warranty.
1. Resetting of safety thermostats, circuit breakers, over load protectors, and/or fuse replacements are not covered by this warranty unless warranted conditions are the cause.
2. All problems due to operation at voltages or phase other than specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage and/or phase must be the customer’s responsibility.
3. All problems due to electrical connections not made
in accordance with electrical code requirements and wiring diagrams supplied with the equipment are
not covered by this warranty.
4. Replacement of items subject to normal wear, to include such items as knobs, light bulbs; and, normal maintenance functions including adjustments of thermostats, adjustment of micro switches and replacement of fuses and indicating lights are not covered by warranty.
5. Damage to electrical cords and/or plug due to exposure to excessive heat are not covered by this warranty.
6. Full use, care, and maintenance instructions supplied with each machine. Noted maintenance and
preventative maintenance items, such as servicing and
SHIPPING DAMAGE CLAIM PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
cleaning schedules, are customer responsibility. Those miscellaneous adjustments noted are customer responsibility. Proper attention to preventative maintenance and scheduled maintenance procedures will prolong the life of the appliance.
7. Travel mileage is limited to sixty (60) miles from an Authorized Service Agency or one of its sub-service agencies.
8. All labor shall be performed during regular working hours. Overtime premium will be charged to the buyer.
9. All genuine Wells replacement parts are warranted for ninety (90) days from date of purchase on non­warranty equipment. This parts warranty is limited only to replacement of the defective part(s). Any use of
non-genuine Wells parts completely voids any
warranty.
10. Installation, labor, and job check-outs are not
considered warranty and are thus not covered by this warranty.
11. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technician’s ability to perform service are not covered by warranty. This includes institutional and correctional facilities.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This should be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Wells Bloomfield cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
122 306626 OpManual for HDG-Series Griddles
xi
Page 3
TABLE OF CONTENTS
ENGLISH
WARRANTY xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 3 AGENCY LISTING INFORMATION 3 INSTALLATION 4 OPERATION 8 CLEANING INSTRUCTIONS 10 TROUBLESHOOTING SUGGESTIONS 12 PARTS & SERVICE 13 CUSTOMER SERVICE DATA 13
FRANÇAIS DESCRIPTION ET AVERTISSEMENTS DE SÛRETÉ 14
SPÉCIFICATIONS 15 FONCTIONNALITÉS ET COMMANDES 16 PRÉCAUTIONS & RENSEIGNEMENTS D’ORDRE GÉNÉRAL 17 INFORMATIONS CONCERNANT LES AGENCES 17 INSTALLATION 18 FONCTIONNEMENT 22 INSTRUCTIONS POUR LE NETTOYAGE 24 CONSEILS POUR LE DÉPANNAGE 26
ENGLISH
INTRODUCTION
Thank You for purchasing this Wells Bloomfield appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it
gives you the very best performance and a long, economical service life. This manual contains the information needed to properly install this appliance, and to use and care for the
appliance in a manner which will ensure its optimum performance.
SPECIFICATIONS
MODEL STYLE FUEL
122 306626 OpManual for HDG-Series Griddles
HDG-2430G
HDG-3630G
HDG-4830G
2 Dual Burners w/
Individual Control
3 Dual Burners w/
Individual Control
4 Dual Burners w/
Individual Control
Natural Gas 5.0” W.C.
Propane (LP) 10” W.C.
Natural Gas 5.0” W.C.
Propane (LP) 10” W.C.
Natural Gas 5.0” W.C.
Propane (LP) 10” W.C.
MANIFOLD
PRESSURE
B.T.U.
per HOUR
60,000
90,000
120,000
1
Page 4
ENGLISH
FEATURES & OPERATING CONTROLS
Fig. 1 Heavy Duty Gas Griddle - Features & Operating Controls
122 306626 OpManual for HDG-Series Griddles
2
Page 5
PRECAUTIONS AND GENERAL INFORMATION
This appliance is intended for use in commercial establishments only.
This appliance is intended No other use is agents.
This appliance must be installed by a technician qualified and certified or licensed to install gas-fired equipment. A licensed technician must perform the initial start-up and adjustment of the appliance.
Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
Cleanliness of this appliance is essential to good sanitation. Read and follow all included cleaning instructions and schedules to ensure the safety of the food product.
DO NOT submerge appliance or burners in water. This appliance is not jet stream approved. DO NOT direct water jet or steam jet at this appliance, or at any control. DO NOT splash or pour water on, in or over any controls. DO NOT wash counter around this appliance with water jet. Burners which have become wet must be thoroughly dried before use.
Griddle surface will be very hot when in use. Contact will cause severe injury.
This appliance must be operated with the supplied 4” legs properly installed.
Do not operate this appliance if the smell of gas is present. Turn off all gas supply valves and move to a remote location to call your Authorized Wells Service Agent for service.
The technical content of this manual, including any parts breakdown illustrations and/or adjustment procedures, is intended for use by qualified technical personnel only.
Any procedure which requires the use of tools must be performed by a qualified technician.
This manual is considered to be a permanent part of the appliance. This manual and all supplied instructions, diagrams, schematics, parts breakdown illustrations, notices and labels must remain with the appliance if it is sold or moved to another location.
122 306626 OpManual for HDG-Series Griddles
recommended or authorized by the manufacturer or its
to prepare food for human consumption.
WARNING:
FIRE HAZARD
All servicing of the gas supply and combustion components of this appliance must be performed by a technician trained and certified in the maintenance of gas appliances. Improper servicing of gas equipment can result in fire and explosion.
CAUTION:
HOT SURFACE
Exposed surfaces can be hot to the touch and may cause burns.
AGENCY LISTING INFORMATION
ENGLISH
This appliance conforms to NSF Standard 4 for sanitation only if installed in accordance with the supplied Installation Instructions and maintained according to the instructions in this manual.
This appliance meets ANSI Z.83.11 specifications for gas-fired food service equipment.
This appliance is Canadian Standards Association design certified for gas operation
3
STD 4
Page 6
INSTALLATION
ENGLISH
NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.
This appliance must be properly ventilated. Failure to provide and maintain proper ventilation of exhaust gasses can result in severe injury or death.
WARNING:
FIRE HAZARD
Do not store gasoline or any other flammable or combustible material near this appliance. The open flame can cause such materials to ignite.
The area where the griddle is installed must be kept clear of combustibles and flammables. This includes mops, rags, grease, wrapping paper and electric cords.
NOTICE: Manufacturer’s warranty on this griddle is in effect only when the griddle is installed in accordance with these instructions and local codes and ordinances or, in the absence of local codes, the National Fuel Gas Code, ANSI Z223.1 (current edition). The manufacturer of this griddle assumes no liability for any damage or injury resulting from failure to comply with this notice.
DANGER:
HEALTH HAZARD
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the appliance before connecting performing any installation procedure.
Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.
Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.
COMPONENTS
Dual Burner (-2430G, 2 ea.; -3630G, 3 ea.; -4830H, 4 ea.) Adjustable Legs (set of 4) Grease Tray (-2430G, 1 ea.; -3630G, 1 ea.; -4830H, 2 ea.)
SETUP
Setup the griddle only on a firm, level, non-combustible surface. Verify local codes for requirements. Concrete, tile, terrazzo or metal surfaces are recommended. Metal or tile over combustible material may not meet code for non-combustible surfaces.
Install the provided adjustable legs, one on each corner of the appliance, in the holes provided. Verify that the unit sits firmly ON ALL FOUR LEGS. With the adjustable legs, adjust as required to level the appliance. All four legs must be adjusted to firmly contact the countertop in order to prevent tipping.
Adequate clearance for air openings in the cabinet must be provided. Refer to the Installation Instruction Sheet for required clearances. Maintain required clearances between the appliance and adjacent combustible surfaces.
The griddle must be installed in an area with sufficient make-up air for proper combustion, and must be installed such that the flow of combustion and ventilation air will not be obstructed.
When used with an exhaust fan, special precautions must be observed to avoid interference with the operation of the griddle, such as drafts and air starvation.
122 306626 OpManual for HDG-Series Griddles
4
Page 7
INSTALLATION (continued)
GAS APPLIANCE CODE COMPLIANCE
The installation of gas piping from the outlet side of the gas meter or service regulator to the griddle must be performed by a technician qualified and certified or licensed to install gas-fired equipment.
A licensed and qualified technician must perform the initial startup and adjustment of this appliance.
The installation of this gas-fired appliance must conform to local codes, or in the absence of such codes, with the current edition of National Fuel Gas Code ANSI Z223.1.
For use in the State of Massachusetts, this appliance must be installed in compliance with Massachusetts Fuel Gas and Plumbing Code CMR 248.
The installation of this gas-fired appliance must comply with applicable portions of NFPA 96 for ventilation. The current edition of NFPA 96 (Standard for the Installation of Equipment for the Removal
of Smoke and Grease Laden Vapors from Commercial Cooking Equipment) specifies ventilation requirements to ensure the removal
of exhaust gasses and products of combustion. IT IS THE RESPONSIBILITY OF THE INSTALLER TO ENSURE
THAT THIS GAS GRIDDLE INSTALLATION CONFORMS TO ALL APPLICABLE CODES AND ORDINANCES.
The venting of this appliance must not be obstructed, nor may such venting interfere with the flow of combustion air required for proper operation of the gas burners.
Additionally:
1. The gas supply line used to connect the griddle to the gas supply system must be black iron pipe, or other material as approved by local ordinance for gas piping.
2. Gas supply piping must be inside 3/4” diameter or greater.
3. Use pipe sealant made specifically for gas piping on all pipe joints. Apply sealant sparingly to the male threads only Sealant must be resistant to the action of LP gas.
4. Verify that all supply piping is clean and free of obstructions, dirt,
122 306626 OpManual for HDG-Series Griddles
chips and pipe sealant compound prior to installation.
5. All pipe joints must be checked for leaks before lighting. Leak checks should be performed with a soap and water solution. NEVER CHECK FOR LEAKS WITH AN OPEN FLAME.
.
DANGER:
FIRE AND EXPLOSION HAZARD
NEVER use an open flame to check for gas leaks. Fire and explosion may result.
WARNING:
RISK OF INJURY
Installation procedures must be performed by a qualified technician with full knowledge of all applicable gas-fired appliance codes. Failure can result in personal injury and property damage.
IMPORTANT:
All pipe joints must be checked for leaks before lighting. Leak checks should be performed with a soap and water solution.
IMPORTANT:
Information on the construction and installation of ventilating hoods may be obtained from the current edition of NFPA 96
Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equipment.
Copies of this standard are available from the Nation Fire Protection Assn.:
NFPA 1 Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9101
ENGLISH
5
Page 8
INSTALLATION (continued)
ENGLISH
DANGER:
FIRE AND EXPLOSION HAZARD
NEVER use an open flame to check for gas leaks. Fire and explosion may result.
IMPORTANT:
All pipe joints must be checked for leaks before lighting. Leak checks should be performed with a soap and water solution.
WARNING:
FIRE HAZARD
This griddle is supplied with a gas pressure regulator. Failure to properly install the supplied regulator will result in an extremely hazardous condition.
Flow arrow stamped on body of regulator must point toward the griddle.
Vent hole must point UP.
IMPORTANT:
Verify fuel gas type. If the available fuel does not match the nameplate specification, exchange the hotplate for the correct type.
IMPORTANT:
The appliance and its individual manual shutoff valve must be disconnected from supply system piping during any pressure testing of that system at pressures in excess of 1/2 p.s.i. (3.5 kPa).
Also, the appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping at test pressures equal to or less than 1/2 p.s.i. (3.5 kPa).
INSTALLING THE GAS GRIDDLE
Refer to the nameplate. Verify the fuel type and pressure, which must match the nameplate specifications. Connecting the hotplate to the wrong fuel type and/or pressure will compromise the safety and/or performance of the appliance.
BE SURE TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE SURFACES.
The griddle must be placed in its final operational position and leveled front-to-back and side-to-side, with a spirit level, prior to beginning the gas piping installation. Re-check the level of the unit at the conclusion of the gas piping installation.
Each gas griddle is supplied with a separate gas pressure regulator, which must be installed on the manifold pipe protruding from the rear of the griddle. Ensure that the regulator is installed such that the flow arrow stamped on the body of the regulator points toward the griddle. Failure to properly install the supplied regulator will result in an ex­tremely hazardous condition.
A moisture trap (drip leg) consisting of a tee, 4” nipple pointing down, and cap must be installed upstream of the gas pressure regulator.
A manual gas shut-off valve may be required by local codes and is, in any case, strongly recommended. The shut-off valve must be installed between the gas supply piping and the gas pressure regulator.
VENT
SUPPLIED REGULATOR
BACK OF GRIDDLE
GAS
SHUT-OFF
VALVE*
GAS SUPPLY*
Fig. 2 Gas Supply Piping
It is the responsibility of the gas piping installer to identify the code requirement for a shut-off valve.
Shut-off valves, moisture trap and all associated piping must be supplied by the gas piping installer.
FLOW
DRIP LEG*
* by others
122 306626 OpManual for HDG-Series Griddles
6
Page 9
INSTALLATION (continued)
SET GAS PRESSURE:
Gas pressure regulator is factory set.
SET PILOT FLAME:
Remove all burner control knobs, then remove the front panel. The pilot adjustments are near the control valve for each set of
burners. Using a small, flat-blade screwdriver, turn the screw clockwise to
decrease the flame size, or counter-clockwise to increase the flame size.
Adjust the pilot flame to 1/4” high. Test for operation: all sections of the burner must light without undue delay. Drafty conditions may require a higher flame to allow the pilot to remain lit.
Replace the front panel and all knobs before returning the unit to service.
ADJUST BURNER FLAME:
Remove all burner control knobs, then remove the front panel. Turn an individual burner on. Loosen the locking screw on the shutter. Turn the shutter to admit more or less air as required. Adjust the
air shutter until the flame is mostly blue in color. Tighten the locking screw when finished. Replace the front panel
and all knobs before returning the unit to service.
IMPORTANT:
Adjustments must be performed by a qualified technician only.
IMPORTANT:
The griddle is shipped from the factory equipped for natural gas and adjusted for sea level to 2000 feet elevation. For conversion to LP / Propane, or for operation above 2000 feet elevation, contact your Authorized Wells Service Agency.
ENGLISH
122 306626 OpManual for HDG-Series Griddles
Fig. 3 Adjustments
7
Page 10
OPERATION
ENGLISH
WARNING:
FIRE HAZARD
IF YOU SMELL GAS:
¤ DO NOT try to light
any appliance. ¤ DO NOT touch any
electrical switch ¤ DO NOT use any
telephone in your building.
In the event a gas odor is detected, shut down the unit at the main gas shut­off valve and contact your local gas supplier from a neighboring location.
Follow the instructions received from the gas supplier immediately and exactly.
GENERAL OPERATIONAL NOTES
Carefully read the description of the griddle operation on the specification sheet.
Do NOT use this appliance if it has been submerged in water. Call a qualified technician to examine the appliance and to service or replace any component which has been submerged. Burners which have been allowed to become wet must be thoroughly dried before use.
For initial startup, and any time the gas supply has been shut-off, it may take several minutes to light the pilot while air in the piping and manifolds is purged.
The burner control knobs must be turned by hand only. Never use tools to turn the control knob. If the knob will not turn by hand, DO NOT attempt to force or repair it. Contact your Authorized Wells Service Agency for repairs. Forced or improperly repaired valves pose the risk of fire and/or explosion.
Make sure burners, pilot burner and grease tray are properly installed before attempting to operate.
LIGHTING THE PILOT FLAME
Before lighting the pilot light, smell all around the appliance area for gas. Be sure to smell near floor level because some gas is heavier than air and will settle to the floor.
For initial startup, and any time the gas supply has been shut-off, it may take several minutes to light the pilot while air in the piping and manifolds is purged.
The pilot light must be lighted by hand: Turn all control knobs to the full OFF position. The pilot is located adjacent to one leg of the burner, and is
accessible through the front panel opening. Be sure the gas shut-off valve is ON and the appliance has had
time for the air to be purged from the lines. Attempt to light the pilot every 15 seconds after the gas valve is turned on.
Light the pilot with a long match or fireplace lighter. DO NOT use a cigarette lighter.
SHUT DOWN INSTRUCTIONS
Turn all burner knobs to OFF. Turn all pilots OFF. Turn the main gas supply OFF.
122 306626 OpManual for HDG-Series Griddles
8
Page 11
OPERATION (continued)
SEASON THE GRIDDLE SURFACE
As manufactured, the steel surface of your Wells griddle has microscopic pores. It is important to fill these pores with oil in order to provide a hard, non-stick cooking surface. a. Preheat the griddle surface to 375ºF (191ºC). b. Spread a light film of cooking oil over the entire griddle surface c. Allow the oil film to cook in for approximately 2 minutes, or until it smokes. d. Wipe the griddle surface with a clean damp cloth until all oil is removed. e. For new griddles, repeat this procedure 2-3 times until the griddle has a slick, clean surface.
OPERATION
Inspect the unit for cleanliness before use. Clean as necessary: See Cleaning Instructions, page 10.
Be sure the pilot light is lit before operation. See Lighting the Pilot Light, page 8.
The burner control knobs must be turned by hand only. Never use tools to turn the control knob.
The control used in this gas griddle provides a continuous range of settings from OFF to ON.
Light the burner by turning the control knob to the ON position until fire forms completely in all sections of the burner. Set the control knob to the desired position. The setting can be readjusted at any time.
Fig. 4 Burner Control
Cooking Recommendations:
Save energy by turning the temperature control knob OFF any time the
122 306626 OpManual for HDG-Series Griddles
griddle is not in use. Gas burners provide full heat instantly, making it unnecessary to leave the unit on during intermittent use.
WARNING:
FIRE HAZARD
NEVER attempt to force or repair a stuck control valve. Contact your Authorized Wells Service Agency for repairs. Forced or improperly repaired valves pose the risk of fire and/or explosion.
WARNING:
FIRE AND EXPLOSION HAZARD
If the pilot light should be extinguished, turn off the gas shut-off valve. Allow the appliance to vent for five minutes before attempting to re-light.
CAUTION:
HOT SURFACE
Exposed surfaces can be hot to the touch and may cause burns.
ENGLISH
9
Page 12
CLEANING INSTRUCTIONS
ENGLISH
WARNING:
FIRE HAZARD
Shut off the gas supply valve before cleaning.
CAUTION:
BURN HAZARD
Allow hotplate to cool completely before cleaning.
IMPORTANT: DO NOT spill or pour water into controls.
DO NOT submerge griddle cabinet in water. Damage to internal components will occur. Damage to internal components from water damage is NOT covered by warranty.
DO NOT steel wool or metal scouring pads to clean cabinet or grease tray.
Good sanitation is vital to the quality of the final food product. Be sure to clean in all corners and crevices where grease and other cooking debris can accumulate.
PREPARATION
Turn control valve to a low setting before cleaning. Allow griddle to cool to this lower setting before cleaning.
FREQUENCY
Daily
TOOLS
Bristle Brush Clean Cloth or Sponge Mild Detergent Cleaner Formulated for Stainless Steel Warm Water
DAILY CLEANING
1. Pour a small amount of water on the griddle surface and let it "sizzle".
2. Clean the griddle surface. Use a pumice stone or griddle brick to scrape food waste. Clean the griddle surface down to bright metal. Wipe off any remaining powder residue.
IMPORTANT: NEVER USE STEEL WOOL TO CLEAN THE GRIDDLE SURFACE!
DO NOT use detergent or oven cleaner to clean the griddle surface.
3. Use a soft-bristled fiber brush in a circular motion to remove any remaining food particles.
4. Turn temperature control to OFF. Allow the griddle surface to cool, then wipe the surface with a clean cloth. Dry the griddle surface thoroughly.
IMPORTANT: SEASON THE COOKING SURFACE AFTER EACH CLEANING. See page 9.
5. At least once each day, the grease trough must be thoroughly cleaned. Using a scraper, remove all grease and food waste from the grease trough by pushing it down the waste hole and into the grease tray.
6. After scraping all cooking waste from grease trough into the grease tray, take the grease drawer to the kitchen cleaning area and properly dispose of all waste. a. Clean drawer with hot water and a mild detergent. b. Dry drawer thoroughly and reinstall in griddle.
7. Wipe down exterior of griddle cabinet with a clean cloth and non­ abrasive cleanser. Rinse thoroughly with water and a clean cloth. Dry with a soft clean cloth.
Procedure is complete.
122 306626 OpManual for HDG-Series Griddles
10
Page 13
CLEANING INSTRUCTIONS (continued)
PREPARATION
Turn gas shut-off valve OFF. Allow griddle to cool before cleaning.
FREQUENCY
As Needed
TOOLS
Bristle Brush Clean Cloth or Sponge Mild Detergent Cleaner Formulated for Stainless Steel Warm Water
CLEANING BURNERS
If one or more individual flame openings does not light, or if the flame is intermittent or uneven, the burner may need to be cleaned.
Turn shut-off valve OFF. Remove all control knobs and remove front panel.
Note position of burner assemblies in cabinet. Remove burners. Examine burner assemblies. Note position of air shutters before
cleaning. Clean food particles from burners with warm water, mild detergent and a bristle brush. Rinse by wiping with a soft cloth dampened with clean water. Wipe exterior surfaces dry with a soft clean cloth. Allow burners to air dry so that interior passages are completely free of water.
Examine burners to be sure the air shutters are in their proper position. Reinstall burners with flame openings “up”. The venturi / air shutter slides over the nozzle of the control valve. The pegs on the rear of the burner set in corresponding notches in the rear burner support bracket. The pegs on the front of the burner set on the front support bracket.
Turn shut-off valve ON and light pilot light. Reinstall front panel and all control knobs. Test all burners for proper operation.
122 306626 OpManual for HDG-Series Griddles
Procedure is complete.
WARNING: FIRE HAZARD
Shut off the gas supply valve before cleaning.
IMPORTANT: DO NOT spill or pour water into burners or controls,
DO NOT submerge griddle cabinet in water. Damage to internal components will occur. Damage to internal components from water damage is NOT covered by warranty.
ENGLISH
11
Page 14
ENGLISH
TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
Pilot will not light Gas supply off Check main / unit gas valves
Burners won’t light Gas supply off Check main / unit gas valves
Air in lines Turn pilot valve on. Attempt to
light pilot every 15 sec.
Pilot valve not on Turn pilot valve on / adjust
Air in lines Turn gas valve on. Attempt to
light pilot every 15 sec.
Pilot burner not lit Turn off gas - allow unit to
vent for 5 minutes. Turn gas back on and light pilot
One burner assembly won’t light
Portions of a burner won’t light or have erratic flame
Burner not hot enough Temperature control not set Adjust for desired temperature
NOTE: There are no user
Control not on Turn control knob to ON
Set to desired setting when lit
Water in burner Remove burner and dry
thoroughly
Damaged temperature control, burner or other internal component
Burner wet or flame opening(s) clogged
Shutter or nozzle out of adjustment
Damaged temperature control, burner or other internal component
Contact Authorized Wells Service Agency for repairs
Clean and dry burner
Contact qualified technician for adjustment
Contact Authorized Wells Service Agency for repairs
serviceable components in the burner assemblies or in the control valves. In all cases of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
122 306626 OpManual for HDG-Series Griddles
12
Page 15
PARTS & SERVICE
DESCRIPTION PART NO.
LEGS, ADJUSTABLE 4” METAL (SET of 4) 20563
IMPORTANT: Use only factory authorized service parts and replacement filters.
For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call:
Wells Bloomfield, LLC
2 Erik Circle P. O. Box 280 Verdi, NV 89439
Service Parts Dept. phone: (775) 689-5707 fax: (775) 689-5976
Service Parts Department can supply you with the name and telephone number of the WELLS AUTHORIZED SERVICE AGENCY nearest you.
ENGLISH
CUSTOMER SERVICE DATA
RESTAURANT _____________________________ LOCATION _____________ INSTALLATION DATE ________________________ TECHNICIAN ___________ SERVICE COMPANY ________________________________________________
122 306626 OpManual for HDG-Series Griddles
ADDRESS ___________________________ STATE ______ ZIP__________ TELEPHONE NUMBER (_____)_____-_________
EQUIPMENT MODEL NO. _______________ EQUIPMENT SERIAL NO. _______________
FUEL (check one) NATURAL GAS PROPANE / LP
please have this information available if calling for service
13
Page 16
FRANÇAIS
Modéle HDG-3630G
Ne pas stocker d’essence ou d'autres liquides inflammables au voisinage de cet
L’installation, le réglage, les modifications, l’entretien ou la maintenance effectués
de manière incorrecte peuvent entraîner des dommages matériels, corporels ou même
la mort. Lire attentivement les instructions relatives à l’installation, au fonctionnement,
à l’entretien et à la maintenance avant d’installer ou de réparer l’équipement.
L’acquéreur de ce matériel doit afficher, en pleine vue du public, les instructions à
suivre en cas de détection d’une odeur de gaz par l’utilisateur. Cette information
doit être obtenue après consultation de la société locale distributrice du gaz.
Ce guide fait partie de l’appareil et doit être remis au propriétaire, au directeur du
restaurant ou à la personne responsable de la formation des utilisateurs de l’appareil.
Des guides supplémentaires sont disponibles chez votre distributeur Wells.
Ce guide doit être lu et compris par toutes personnes installant ou utilisant cet appareil.
Contacter votre distributeur Wells pour toutes questions au sujet de l’installation, du
MANUEL DE L’UTILISATEUR
WELLS GRILL PROFESSIONNEL
MODE D’EMPLOI
POUR VOTRE SÉCURITÉ
appareil ou autres appareils ménagers.
AVERTISSEMENT !
IMPORTANT :
IMPORTANT : NE PAS JETER CE GUIDE
fonctionnement ou de l’entretien de cet appareil.
MODÈLES HDG-2430G HDG-3630G HDG-4830G
Comprend :
INSTALLATION,
& ENTRETIEN
122 306626 OpManual for HDG-Series Griddles
14
Page 17
TABLE DES MATIÈRES
FRANÇAIS DESCRIPTION ET AVERTISSEMENTS DE SÛRETÉ 14
SPÉCIFICATIONS 15 FONCTIONNALITÉS ET COMMANDES 16 PRÉCAUTIONS & RENSEIGNEMENTS D’ORDRE GÉNÉRAL 17 INFORMATIONS CONCERNANT LES AGENCES 17 INSTALLATION 18 FONCTIONNEMENT 22 INSTRUCTIONS POUR LE NETTOYAGE 24 CONSEILS POUR LE DÉPANNAGE 26
INTRODUCTION
Merci d’avoir acquis cet appareil Wells Bloomfield. L’installation correcte, le fonctionnement professionnel et l’entretien régulier de cet appareil assureront ses meilleures performances et sa longue durée de service aux meilleurs coûts. Le présent manuel contient l’information nécessaire pour installer correctement l’appareil et pour l’utiliser et l’entretenir de manière à ce qu’il fonctionne avec des performances optimales.
MODÈLE STYLE COMBUSTIBLE
2 brûleurs avec
HDHP-1230G
HDHP-2430G
HDHP-3630G
122 306626 OpManual for HDG-Series Griddles
*Propane (gaz de pétrole liquide--GPL)
commandes individuelles
4 brûleurs avec
commandes individuelles
6 brûleurs avec
commandes individuelles
SPÉCIFICATIONS
Gaz naturel 5.0” W.C. 53,000
Propane* 10” W.C.
Gaz naturel 5.0” W.C. 106,000
Propane* 10” W.C.
Gaz naturel 5.0” W.C. 159,000
Propane* 10” W.C.
PRESSION DU COLLECTEUR
FRANÇAIS
CONSOMMATION
D’ÉNERGIE
TOTALE (BTU) par
heure
43,000
86,000
129,000
15
Page 18
FONCTIONNALITÉS ET COMMANDES
CONDUIT
D'ÉVACUATION
DES GAZ
SURFACE DE
CUISSON
FRANÇAIS
OUVERTURE DU CONDUIT D'ÉVACUATION DE LA GRAISSE
PLATEAU POUR LA GRAISSE
CONTROLER LE BOUTON
BAC POUR LA GRAISSE
PIEDS
RÉGLABLES
COMPOSANTS
INTERNES
CONTROLER
LA SOUPAPE POUR
LA FLAMME DE BRULEUR
(STANDARD)
ENSEMBLES DE BRÛLEURS
ALLUMAGE DES BRÛLEURS
L'AJUSTEMENT DE FLAMME D'ALLUMAGE
122 306626 OpManual for HDG-Series Griddles
Fig. 5 FONCTIONNALITÉS ET COMMANDES DU GRILL PROFESSIONNEL À GAZ
16
Page 19
PRÉCAUTIONS & RENSEIGNEMENTS D’ORDRE GÉNÉRAL
Cet appareil est prévu exclusivement à l’usage des établissements commerciaux.
Cet appareil est destiné à la cuisson d’aliments pour la consommation humaine. Aucun autre usage n’est recommandé ni autorisé par le fabricant ou ses agents.
Cet appareil doit être installé par un technicien qualifié ou et certifié ou agréé pour l’installation des équipements fonctionnant au gaz. Un technicien qualifié et agréé doit assurer la mise en service et le réglage initiaux de l'appareil.
Les utilisateurs de l’appareil doivent être familiarisés avec l’utilisation de l’appareil, ses limites et ses restrictions associ ées. Le mode d’emploi doit être lu et compris par toutes les personnes installant ou utilisant cet appareil.
La propreté de cet appareil est essentielle à de bonnes conditions sa­nitaires. Lire et suivre toutes les instructions relatives au nettoyage et aux programmes visant à assurer l’innocuité des produits alimentaires.
NE PAS submerger l’appareil ou les brûleurs dans l’eau. Cet appareil n’est pas approuvé pour supporter les jets d’eau. NE PAS orienter de jet d’eau ou de vapeur directement sur cet appareil ou de ses commandes. NE PAS éclabousser ni verser d’eau sur, dans ou par dessus les commandes. NE PAS laver le comptoir entourant l’appareil avec un jet d’eau. Les brûleurs mouillés doivent être complètement séchés avant usage.
Les surfaces de cuisson deviennent très chaudes pendant l’usage. Leur contact provoquera des brûlures graves.
Cet appareil doit être utilisé avec ses pieds de 10 cm (4 po.) de haut correctement installés.
Ne pas utiliser cet appareil en présence d’une odeur de gaz. Fermer tous les robinets à gaz et se rendre dans un lieu éloigné pour appeler un technicien d’entretien agréé par Wells.
La partie technique du présent manuel, y compris tous les schémas éclatés illustrant les pièces et/ou les procédures de réglage, est destinée exclusivement à l’usage de techniciens qualifiés.
Toute procédure exigeant l’emploi d’outils doit être accomplie par un technicien qualifié.
Le présent manuel est considéré être une pièce permanente de l’appareil. Ce manuel et toutes les instructions, schémas, illustrations de pièces éclatées, notices et étiquettes fournis doivent demeurer avec l’appareil si ce dernier est revendu ou déménagé dans un autre local.
122 306626 OpManual for HDG-Series Griddles
INFORMATIONS CONCERNANT LES AGENCES
AVERTISSEMENT!
DANGER D’INCENDIE
Toutes les opérations d’entretien et de réparation des composants servant à l’alimentation et à la combustion du gaz dans cet appareil doivent être effectuées par un technicien qualifié et agréé pour la maintenance des appareils à gaz. L’entretien incorrect des appareils à gaz peut entraîner des incendies et des explosions.
ATTENTION:
SURFACE CHAUDE
Les surfaces exposées peuvent être chaudes au toucher et peuvent occasionner des brûlures.
FRANÇAIS
Cet appareil n’est conforme à la Norme 4 de la fondation nationale de normalisation sanitaire des États-Unis (National Sanitation Foundation-
-NSF) que s’il est installé conformément aux Instructions relatives à l’installation fournies avec l’appareil et si ce dernier est entretenu selon
les instructions du présent manuel. Cet appareil est conforme aux spécifications ANSI Z.83.11 pour les appareils à gaz utilisés dans les établissements préparant des aliments. Cet appareil est d’une conception certifiée pour le fonctionnement au gaz par l’Association canadienne de normalisation (ACN/CSA).
17
Norme 4
Page 20
L'INSTALLATION
FIXATION PAR VIS DANS LE CADRE
TOURNER POUR RÉGLER LA HAUTEUR
REMARQUE : NE PAS jeter le carton ni les autres matériaux d’emballage jusqu’à ce que l’appareil ait été inspecté pour la détection de vices cachés et ait subi des tests de fonctionnement satisfaisants. Consulter la
PROCÉDURE DE RÉCLAMA­TION EN CAS DE DOMMAGES DUS AU TRANSPORT imprimée
sur la face interne de la première page de couverture du présent manuel.
FRANÇAIS
Cet appareil doit être situé dans un local correctement aéré. Le défaut d’assurance et de maintien d’une aération convenable avec mise à l’évent des gaz de combustion peut entraîner des dommages corporels graves ou même la mort.
d’essence ou d'autres matériaux combustibles ou inflammables à proximité de cet appareil. Toute flamme nue peut provoquer l’inflammation de ces matériaux. La zone où le grill est installé doit être dépourvue de tout matériau combustible ou inflammable. Ceux-ci comprennent, notamment, les serpillères, les lavettes ou les chiffons, la graisse, le papier d’emballage et les cordons d’alimentation électriques
NOTICE : La garantie du fabricant concernant cet appareil entre en vigueur exclusivement si l’appareil est installé conformément aux présentes instructions, aux dispositions de la réglementation et des codes locaux, ou en l’absence de codes, de la norme ANSI Z223.1 (édition en vigueur) du code national relatif au gaz combustible (National Fuel Gas Code). Le fabricant de ce grill décline toute responsabilité en cas de dommages corporels ou matériels résultant du défaut d'application des dispositions de la présente notice.
AVERTISSEMENT : Danger d’incendie Ne pas stocker
DANGER:
Danger pour la santé
.
DÉBALLAGE & INSPECTION
Sortir l’appareil du carton avec précaution. Enlever tous les films de protection en plastique, les matériaux d’emballage et les accessoires de l’appareil avant d'entamer toute procédure d'installation et de connexion.
Lire attentivement toutes les instructions du présent manuel et de la Notice-–Instructions relatives à l’installation, incluse avec l’appareil, avant de commencer l’installation.
Lire et assimiler la signification de toutes les étiquettes et schémas fixés sur l’appareil.
Vérifier que tous les composants et accessoires sont présents avant de jeter les matériaux d'emballage. Ranger tous les accessoires dans un lieu convenable pour les utiliser plus tard.
COMPOSANTS
Double brûleur
(-2430G, 2 pièce; -3630G, 3 pièce; -4830H, 4 pièce) Pieds réglables (jeu de 4) Plateau pour la graisse
-4830H, 2 pièce)
INSTALLATION
(-2430G, 1 pièce; -3630G, 1 pièce;
Installer l’appareil uniquement sur une surface solide, horizontale et non combustible. Vérifier les conditions imposées par les codes locaux. Les surfaces en ciment, en carreaux de céramique ou de marbre, ou en métal sont recommandées. Le métal ou les carreaux de céramique posés sur des matériaux combustibles peuvent être incompatibles avec les dispositions du code imposant des surfaces non combustibles.
Installer les pieds fournis avec l’appareil, un pied à chaque coin de l’appareil, dans les trous préparés. Vérifier que l’unité est stable et repose bien SUR LES QUATRE PIEDS. Les pieds étant réglables, les ajuster selon les besoins pour que l’appareil soit horizontal. Les quatre pieds doivent être ajustés pour faire solidement contact avec le comptoir afin d’éviter tout basculement.
Ménager des dégagements adéquats dans l’armoire pour les orifices d’aération. Consulter la Notice—Intructions relatives à l’installation, pour obtenir les dimensions de dégagement obligatoires. Conserver les distances de dégagement nécessaires entre l’appareil et les surfaces combustibles adjacentes.
L’appareil doit être installé dans un lieu où l’air est suffisamment renouvelé pour assurer une combustion correcte et de telle manière que le courant de l’air de combustion et d’aération ne soit pas obstrué .
Lorsqu’on utilise l’appareil avec un ventilateur d’extraction, il faut prendre des précautions spéciales pour éviter toute interférence avec le fonctionnement de l’appareil, tels que courants d’air et privation d’air .
122 306626 OpManual for HDG-Series Griddles
18
Page 21
L'INSTALLATION (a continué)
CONFORMITÉ AU CODE RELATIF AUX APPAREILS À GAZ
L’installation des tuyauteries du gaz entre le côté sortie du compteur à gaz ou du régulateur de l’alimentation publique et l’appareil doit être effectuée par un technicien qualifié et certifié ou agréé pour l’installation des appareils à gaz.
Un technicien qualifié et agréé doit assurer la mise en service et le réglage initiaux de l'appareil.
L’installation de cet appareil à gaz doit être conforme aux codes locaux, ou en l’absence de codes, à l’édition en vigueur de la norme ANSI Z223.1 du Code national applicable au gaz combustible (National Fuel Gas Code—NFGC).
Pour l'usage dans l'Etat de Massachusetts, cet appareil doit être installé en conformité avec le Massachusetts Fuel Gas and Plumbing Code CMR 248.
L’installation de cet appareil à gaz doit être conforme aux parties applicables de la norme NFPA 96 relatives à l’aération. L’édition courante de la norme NFPA 96 précise les conditions obligatoires à remplir pour l'extraction des gaz et des produits de combustion.
L’INSTALLATEUR EST RESPONSABLE D’ASSURER QUE L’INSTALLATION DE CE GRILL À GAZ SOIT CONFORME À TOUS LES CODES ET À TOUTE RÉGLEMENTATION APPLICABLES.
La mise à l’évent de cet appareil ne doit pas être obstruée, et cette mise à l’évent ne doit en aucun cas interférer avec le courant de l’air de combustion exigé pour le fonctionnement correct des brûleurs à gaz.
En outre :
1. La ligne d’alimentation de gaz utilisée pour raccorder le grill au système d’alimentation de gaz doit être un tuyau en acier non revêtu (fer noir) ou autre matériau approuvé par la réglementation locale applicable aux tuyauteries de gaz.
2. La tuyauterie du gaz doit avoir un diamètre intérieur égal ou supérieur à ¾ po. (1,9 cm).
3. Utiliser un mastic pour l’étanchéité des raccords de tuyauterie, spécial pour les tuyauteries à gaz, sur tous les raccords de tuyauterie. Appliquer le mastic en petite quantité uniquement sur les filetages mâles.
122 306626 OpManual for HDG-Series Griddles
Le mastic doit être résistant à l'action du gaz GPL.
4. Vérifier que toute la tuyauterie d’alimentation de gaz est propre et épourvue de toute obstruction, saleté, débris et particules de mastic d'étanchéité avant l’installation .
5. Tous les raccords de tuyauterie doivent être inspectés pour la détection de fuites éventuelles avant l’allumage. Détecter les fuites avec une solution d’eau savonneuse. NE JAMAIS DÉTECTER DE FUITES AVEC UNE FLAMME NUE .
DANGER :
DANGER D’INCENDIE ET
D’EXPLOSION
NE JAMAIS utiliser de flamme nue pour détecter des fuites de gaz. Un incendie et une explosion pourrait se produire.
AVERTISSEMENT : DANGER DE DOM- MAGE CORPOREL
Les procédures d’installation doivent être accomplies par un technicien qualifié ayant pleine connaissance des dispositions des codes en vigueur relatives aux appareils à gaz. À défaut, des dommages corporels et matériels peuvent survenir.
IMPORTANT : Tous les raccords de tuyauterie doivent être inspectés pour la détection de fuites éventuelles avant l’allumage. Détecter les fuites avec une solution d’eau savonneuse.
IMPORTANT : L’information relative à la construction et l’installation des hottes d’aération doit être obtenue dans l’édition en vigueur de la norme NFPA 96
Standard for the Installation of Equipment for the Removal of Smoke and Grease Laden apors from Commercial Cooking Equip­ment. (Norme relative à l’installa­tion d’équipements destinés à l’extraction des fumées et des vapeurs chargées de graisse générées par les appareils de cuisson commerciaux.)
Des exemplaires de cette norme sont disponibles auprès de l’Association nationale pour la protection contre les incendies (National Fire Protection Association—NFPA) NFPA 1 Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9101
FRANÇAIS
19
Page 22
L'INSTALLATION (a continué)
DANGER :
DANGER D’INCENDIE ET
D’EXPLOSION
NE JAMAIS utiliser de flamme nue pour détecter des fuites de gaz. Un incendie et une explosion pourrait se produire.
IMPORTANT :
Tous les raccords de tuyauterie doivent être inspectés pour la détection de
FRANÇAIS
fuites éventuelles avant l’allumage. Détecter les fuites avec une solution d’eau savonneuse .
AVERTISSEMENT :
DANGER D’INCENDIE
Cet appareil à gaz est vendu avec un régulateur de pression. Le défaut d’installation correcte du régulateur de pression crée une situation extrêmement dangereuse. La flèche gravée sur le corps du régulateur doit pointer vers le grill. Le trou d’aération doit pointer vers le HAUT.
IMPORTANT :
Vérifier la nature du gaz combustible. Si le combustible disponible ne correspond pas aux spécifications de la plaque signalétique, échanger l’appareil contre un autre, de type correct.
INSTALLATION DU GRILL À GAZ
Consulter la plaque signalétique. Vérifier la nature et la pression du combusti­ble, qui doivent correspondre aux spécifications indiquées sur la plaque signa­létique. Le raccordement de l’appareil à une alimentation en combustible incorrecte ou sous pression incorrecte compromet­trait la sécurité et/ou les performances de l’appareil.
VÉRIFIER QUE LES DISTANCES DE DÉGAGEMENT OBLIGATOIRES PAR RAPPORT AUX SURFACES COMBUSTIBLES SONT RESPECTÉES.
L’appareil doit être mis en place dans sa position de fonctionnement définitive et mis à niveau horizontalement (l’arrière par rapport au devant, un côté par rapport à l’autre) à l’aide d’un niveau à bulle, avan t de commencer l’installation de la tuyauterie du gaz.
Vérifier de nouveau le niveau horizontal de l’unité apr ès l’in s tal lation de la tuyauterie du gaz.
Chaque appareil à gaz est vendu avec un régulateur de pression séparé, qui doit être installé sur le tuyau du collecteur dépassant à l’arri ère de l’ ap par ei l. Vérifier que le régulateur est installé de manière à ce que la flèche indiquant le débit, gravée sur le corps du régulateur, pointe vers le grill. Le défaut d’installation correcte du régulateur de pressi on cré e une sit uat ion extrêmement dangereuse.
Un purgeur de condensat (collecteur de condensat) comportant un Té, un mamelon de 4 po. (10 cm) pointant vers le bas et un capuchon doit être installé en amont du régulateur de pression de gaz .
Un robinet d’arrêt de gaz manuel peut être exigé par les codes locaux et son installation est fortement recommandée dans tous le s ca s. Le robinet d’arrêt doit être installé entre la tuyauterie d’alimentation de gaz et le régulateur de pression .
RÉGULATEUR FOURNI AVEC
L'APPAREIL
ROBINET
D'ARRÊT
DU GAZ *
ALIMENTATION
DE GAZ *
Fig. 6 Tuyauterie d’alimentation du gaz
L’installateur de la tuyauterie du gaz est responsable d’identifier les dispositions obligatoires du code relatives aux robinets d'arrêt de gaz .
Les robinets d’arrêt, le purgeur de condensat et toute la tuyauterie associée doivent être fournis par l’installateur de la tuyauterie du gaz.
ÉVENT
SENS DU
COURANT
PURGEUR DE CONDENSAT *
* par des tiers
ARRIÈRE DU GRILL
122 306626 OpManual for HDG-Series Griddles
20
Page 23
L'INSTALLATION (a continué)
RÉGLAGE DE PRESSION DU GAZ :
Le régulateur de pression du gaz est réglé en usine .
RÉGLAGE DE LA VEILLEUSE D’ALLUMAGE :
Enlever tous les boutons de commande des brûleurs puis enlever le panneau avant .
Les réglages de veilleuse sont proches du robinet de commande de chacun des jeux de brûleurs .
À l’aide d’un petit tournevis plat, tourner la vis dans le sens horaire pour diminuer la hauteur de la flamme ou dans le sens inverse au sens horaire pour augmenter la hauteur de la flamme .
Régler la flamme de la veilleuse à 0,64 cm (1/4 po.) de hauteur. Essai de fonctionnement : toutes les sections de brûleur doivent s ’allumer sans délai. Dans les lieux à courants d’air, une flamme plus haute peut être nécessaire pour que la veilleuse reste allumée.
Remettre le panneau avant et tous les boutons en place avant de remettre l’unité en service.
RÉGLAGE DE LA FLAMME DE BRÛLEUR :
Enlever tous les boutons de commande des brûleurs puis enlever le panneau avant.
Allumer l’un des brûleurs. Desserrer la vis de blocage sur le volet. Tourner le volet pour admettre plus ou moins d’air, le cas
échéant. Régler le volet d’aération jusqu’à ce que la flamme soit principalement bleue.
Serrer la vis de blocage quand l’opération est terminée. Remettre le panneau avant et tous les boutons en place avant de remettre l’unité en service .
L'AJUSTEMENT DE
FLAMME
DE BRULEUR
122 306626 OpManual for HDG-Series Griddles
PLUS D'AIR
BLOCAGE
VIS DE
MOINS
D'AIR
BOUTON DE
COMMANDE
DU BRÛLEUR
FERMETURE
VOLET
OUVERTURE
ON
OFF
RÉGLAGE DE LA VEILLEUSE D'ALLUMAGE
FLAMME
PLUS
GRANDE
L'AJUSTEMENT DE
FLAMME
D'ALLUMAGE
FLAMME PLUS PETITE
IMPORTANT :
L’appareil et son robinet d’arrêt manuel individuel doivent être déconnectés de la tuyauterie du système d’alimentation pendant les essais de pression de ce système dépassant 1/2 p.s.i. (3,5 kPa).
Il faut également isoler l’appareil du système d’alimentation de gaz en fermant son robinet d’arrêt manuel individuel pendant tous les essais de tuyauterie d’alimentation lorsque les pressions d’essai de la tuyauterie sont égales ou inférieures à 1/2 p.s.i. (3,5 kPa).
IMPORTANT:
Les réglages doivent être exécutés exclusivement par un technicien qualifié.
IMPORTANT:
L’appareil à gaz est expédié de l’usine tout équipé pour le gaz naturel et réglé pour fonctionner à une altitude comprise entre le niveau de la mer et 660 mètres (2 000 pieds). Pour convertir l’appareil au gaz de pétrole liquide (LP) ou au propane, ou pour fonctionner à une altitude de plus de 660 mètres (2 000 pieds), veuillez contacter votre distributeur agréé Wells.
FRANÇAIS
Fig. 7 Réglages
21
Page 24
FONCTIONNEMENT
AVERTISSEMENT:
DANGER D’INCENDIE
SI VOUS SENTEZ LE GAZ:
¤
NE PAS tenter d’allumer
l’appareil
¤ NE toucher à AUCUN
bouton électrique.
¤ NE PAS utiliser le
téléphone situé dans le
FRANÇAIS
bâtiment
.
Si l’on détecte une odeur de gaz, mettre l’unité à l’arrêt en fermant le robinet d’arrêt principal du gaz et contacter la société responsable de l’alimentation en gaz à partir d’un poste téléphonique du
voisinage
.
Suivre immédiatement et exactement les instructions fournies par la société
distributrice du gaz
COMMENTAIRES D’ORDRE GÉNÉRAL SUR LE FONCTIONNEMENT
Lire attentivement la description du fonctionnement du grill sur la notice de spécifications.
NE PAS utiliser l’appareil s’il a été immergé dans l'eau. Appeler un technicien qualifié pour examiner l’appareil et le réparer ou remplacer
.
tout composant ayant été submergé. Les brûleurs qui ont pu être mouillés doivent être complètement séchés avant usage.
Pour la mise en route initiale, et chaque fois que l’alimentation de gaz a été coupée, il pourra falloir plusieurs minutes pour allumer la veilleuse pendant que l’air est purgé de la tuyauterie et des collecteurs.
Les boutons de commande des brûleurs ne doivent être tournés qu’à la main. Ne jamais utiliser d’outil pour tourner les boutons. Si un bouton ne tourne pas à la main, NE PAS essayer de le forcer ni de le réparer. Pour toute réparation, contacter le distributeur agréé Wells. Les boutons ou robinets forcés ou mal réparés posent un risque d’incendie et/ou d’explosion.
S’assurer que les brûleurs, le brûleur de la veilleuse et le plateau à graisse sont correctement installés avant d’essayer la mise en marche.
ALLUMAGE DE LA VEILLEUSE
Avant d’allumer la veilleuse, sentir l’atmosphère autour de l’appareil pour détecter toute trace de gaz. Ne pas oublier de sentir près du sol
.
parce que le gaz est plus lourd que l’air et s’accumulerait au niveau du sol.
122 306626 OpManual for HDG-Series Griddles
Pour la mise en route initiale, et chaque fois que l’alimentation de gaz a été coupée, il pourra falloir plusieurs minutes pour allumer la flamme de la veilleuse pendant que l’air est purgé de la tuyauterie et des collecteurs.
La flamme de la veilleuse doit être allumée à la main : Tourner tous les boutons de commande jusqu’à la positions OFF
(FERMETURE). La veilleuse est adjacente à l’un des pieds de brûleur et est
accessible à travers l’ouverture du panneau avant . S’assurer que le robinet d’arrêt du gaz est sur ON (OUVERTURE)
et que l’air a eu le temps d’être purgé des lignes de gaz. Essayer d’allumer la flamme de la veilleuse toutes les 15 secondes après avoir ouvert le robinet d’arrêt du gaz .
Allumer la veilleuse avec une longue allumette ou un briquet pour feu de cheminée. NE PAS utiliser de briquet pour cigarette.
INSTRUCTIONS POUR LA MISE À L’ARRÊT
Tourner tous les boutons de brûleur jusqu’à la position OFF (FERMETURE).
Éteindre toutes les veilleuses d’allumage . Mettre le robinet d’arrêt général sur la position OFF (FERMETURE).
22
Page 25
FONCTIONNEMENT (a continué)
APPRÊT DE LA SURFACE DU GRILL
La surface en acier manufacturé du grill Wells comporte de microscopiques pores. Il est important de remplir ces interstices d’huile pour obtenir une surface de cuisson dure et non adhésive . a. Préchauffer le grill jusqu’à 191 °C (375 ºF). b. Répandre une mince pellicule d’huile d’alimentation sur la totalité de la surface du grill. c. Laisser cuire cette pellicule d’huile pendant environ 2 minutes, ou jusqu’à ce que de la fumée apparaisse. d. Essuyer la surface du grill avec un chiffon humide jusqu’à ce que l’huile ait disparu. e. Pour les grills neufs, recommencer cette opération 2 à 3 fois, jusqu’à ce que la surface du grill soit luisante et propre.
FONCTIONNEMENT DU GRILL
Inspecter l’unité pour vérifier sa propreté avant usage. Nettoyer le cas échéant : voir page 24.
S’assurer que la veilleuse est allumée avant de faire fonctionner le grill. Voir la section Allumage de la flamme de la veilleuse, page 22 .
Les boutons de commande des brûleurs ne doivent être tournés qu’à la main. Ne jamais utiliser d’outil pour tourner les boutons.
Le bouton de commande de ce grill à gaz offre une plage continue de réglages entre la position OFF (FERMETURE) à ON (OUVERTURE).
Allumer la veilleuse en tournant le bouton de commande jusqu’à la position ON (OUVERTURE), et ce, jusqu’à ce que l’allumage soit complet dans toutes les sections de brûleur. Régler le bouton de commande sur la position souhaitée. On peut ajuster le réglage à tout moment .
OFF
POSITION OFF (FERMETURE) POSITION ON (OUVERTURE)
Fig. 8 Commande de brûleur
RECOMMANDATIONS POUR LA CUISSON :
122 306626 OpManual for HDG-Series Griddles
Économiser l’énergie en tournant le bouton de commande de température jusqu’à la position OFF (FERMENTURE) chaque fois que le grill reste inutilisé. Les brûleurs à gaz fournissent instantanément une pleine chaleur, ce qui rend inutile de laisser l’unité allumée lorsqu’on n’a pas besoin de l’utiliser.
OFF
ONON
ON
ON
OFF
OFF
AVERTISSEMENT:
DANGER D’INCENDIE
NE JAMAIS tenter de forcer ou de réparer un bouton ou robinet de commande bloqué. Pour toute réparation, contacter le distributeur agréé Wells. Les boutons ou robinets forcés ou mal réparés posent un risque d’incendie et/ou
d’explosion
.
AVERTISSEMENT:
DANGER D’INCENDIE ET D’EXPLOSION
Si la veilleuse d’allumage venait à s’éteindre, arrêter le gaz au robinet d’arrêt général. Laisser l’appareil se purger pendant cinq minutes avant d’essayer de rallumer la veilleuse.
ATTENTION : SURFACE CHAUDE
Les surfaces exposées peuvent être chaudes au toucher et peuvent occasionner des brûlures .
FRANÇAIS
23
Page 26
INSTRUCTIONS POUR LE NETTOYAGE
AVERTISSEMENT:
DANGER D’INCENDIE
Fermer le robinet d’arrêt du gaz avant le nettoyage
ATTENTION :
DANGER DE BRÛLURES
Laisser complètement refroidir l’appareil avant de le nettoyer.
FRANÇAIS
IMPORTANT :
NE PAS renverser ni verser d’eau sur les boutons de commande.
NE PAS submerger l’armoire du grill dans l'eau. Ceci endommagerait les composants internes. Les dommages occasionnés par l’eau aux composants internes ne sont PAS couverts par la garantie.
NE PAS utiliser de tampons métalliques à récurer pour nettoyer l’armoire ou le plateau à graisse.
Un bonne hygiène est vitale pour la qualité des produits alimentaires finis. Il faut s'assurer de bien nettoyer dans tous les coins et toutes les fissures où la graisse ou autres débris alimentaires ont pu s'accumuler .
PRÉPARATION
Tourner le robinet de commande jusqu’à un réglage bas avant le nettoyage. Laisser refroidir le grill jusqu’à son réglage le plus bas avant de nettoyer.
.
FRÉQUENCE
Tous les jours
USTENSILES
Brosse à soies Chiffon ou éponge propre Détergent doux Eau chaude Produit nettoyant compatible avec l’acier inoxydable
NETTOYAGE QUOTIDIEN
1. Verser une petite quantité d'eau sur la surface du grill et la laisser bouillonner.
2. Nettoyer la surface du grill. Utiliser un pierre ponce ou un grattoir de grill pour gratter tous les déchets alimentaires. Nettoyer la sur face du grill jusqu’à ce que le métal brille. Essuyer tous les résidus de poudre restants.
IMPORTANT : NE JAMAIS UTILISER DE TAMPONS MÉTALLIQUES À RÉCURER POUR NETTOYER LA SURFACE DU GRILL !
NE PAS utiliser de détergent ni de produit de nettoyage pour four pour nettoyer la surface du grill.
3. Utiliser une brosse à poils doux en faisant des mouvements circulaires pour éliminer toutes les particules alimentaires restantes.
122 306626 OpManual for HDG-Series Griddles
4. Tourner le bouton de commande de température jusqu’à la position OFF (ARRÊT). Laisser refroidir la surface du grill puis essuyer la surface avec un chiffon propre. Sécher complètement la surface du grill.
IMPORTANT : Apprêter la surface de cuisson après chaque nettoyage. Voir page 23.
5. Nettoyer à fond le bac à graisse au moins une fois par jour. À l’aide d’un grattoir, enlever toute la graisse et tous les déchets de
nourriture du bac à graisse en les poussant à travers le trou d’évacuation jusqu’au plateau à graisse .
6. Après avoir gratté tous les déchets de cuisson du bac à graisse et
les avoir acheminés sur le plateau à graisse, emmener le tiroir à graisse dans l’aire de lavage de la cuisine et disposer de tous les déchets de façon réglementaire a. Nettoyer le tiroir à l’eau chaude et avec un détergent doux . b. Sécher complètement le tiroir et le réinstaller dans le grill .
7. Essuyer l’extérieur de l’armoire du grill avec un chiffon propre et un
nettoyant non abrasif. Rincer abondamment à l’eau et frotter avec un chiffon propre. Sécher avec un chiffon propre et doux .
La procédure de nettoyage est terminée.
24
Page 27
INSTRUCTIONS POUR LE NETTOYAGE (a continué)
PRÉPARATION
Fermer le robinet d’arrêt (sur la position OFF/FERMETURE). Laisser refroidir le grill avant de le nettoyer.
FRÉQUENCE
Selon les besoins
USTENSILES
Brosse à soies Chiffon ou éponge propre Détergent doux Eau chaude Produit nettoyant compatible avec l’acier inoxydable
NETTOYAGE DES BRÛLEURS
Si un ou plusieurs trous individuels ne laissent pas s’échapper de flamme ou si la flamme est intermittente ou irrégulière, le brûleur a probablement besoin d’être nettoyé.
Fermer le robinet d’arrêt (sur la position OFF/FERMETURE). Enlever tous les boutons de commande et le panneau avant.
Repérer la position des ensembles de brûleur dans l’armoire. Enlever les brûleurs.
Examiner les ensembles de brûleur. Repérer la position des volets d’aération avant le nettoyage. Nettoyer les débris alimentaires des brûleurs à l’eau chaude, avec du détergent doux et une brosse à soies. Rincer et essuyer avec un chiffon doux et humecté d'eau propre. Essuyer les surfaces extérieures avec un chiffon propre, sec et doux. Laisser sécher les brûleurs à l’air pour que les passages intérieurs soient totalement dépourvus d’eau.
Examiner les brûleurs pour vérifier la bonne position des volets d’aération. Remettre les brûleurs en place avec les trous de sortie des flammes orientés vers le haut. Le venturi/volet d’aération glisse sur la buse du robinet de commande. Les ergots situés à l’arrière des brûleurs s’enclenchent dans des cavités correspondantes situées sur le support de brûleur. Les ergots situés à l’avant des brûleurs s’enclenchent dans les supports avant.
Ouvrir le robinet d’arrêt (sur la position ON/OUVERTURE) et allumer la
122 306626 OpManual for HDG-Series Griddles
veilleuse. Remettre en place le panneau avant et tous les boutons de
commande. Essayer tous les brûleurs pour vérifier leur bon fonctionnement. La procédure de nettoyage est terminée.
AVERTISSEMENT:
DANGER D’INCENDIE
Fermer le robinet d’arrêt du gaz avant le nettoyage
.
.
IMPORTANT :
NE PAS renverser ni verser d’eau sur les boutons de commande.
NE PAS submerger l’armoire du grill dans l'eau. Ceci endommagerait les composants internes. Les dommages occasionnés par l’eau aux composants internes ne sont PAS couverts par la garantie.
FRANÇAIS
25
Page 28
CONSEILS POUR LE DÉPANNAGE
SYMPTÔMES CAUSE POSSIBLE SOLUTION CONSEILLÉE
Alimentation de gaz fermée
Vérifier les robinets d’arrêt principal/de chaque unité.
La veilleuse ne s’allume pas
FRANÇAIS
Les brûleurs ne s'allument pas
Un ensemble de brûleur ne s’allume pas
Air dans les lignes Le bouton d’allumage de la
veilleuse n’est pas ouvert
Alimentation de gaz fermée
Air dans les lignes
La veilleuse n’est pas allu­mée
Le bouton de commande est fermé
De l’eau dans le brûleur
Bouton de commande de température, brûleur ou au­tre composant interne en­dommagé
Allumer la veilleuse. Essayer d’allumer la veilleuse toutes les 15 secondes.
Ouvrir/régler le bouton d’allumage de la veilleuse
Vérifier les robinets d’arrêt principal/de chaque unité.
Allumer la veilleuse. Essayer d’allumer la veilleuse toutes les 15 secondes.
Fermer le robinet d’arrêt du gaz – lais­ser l’unité se purger à l'évent pendant 5 minutes. Ouvrir le robinet d’arrêt du gaz et allumer la veilleuse.
Ouvrir le bouton de commande (ON/ OUVERTURE). Régler les flammes de brûleurs.
Enlever le brûleur et le laisser sécher complètement
Contacter le distributeur agréé Wells pour effectuer les réparations.
122 306626 OpManual for HDG-Series Griddles
Des parties de brûleur ne s’al­lument pas ou leur flamme est irrégulière
La flamme du brûleur n’est pas assez chaude
Volet ou buse déréglée REMARQUE : Les ensembles de brûleur ou les robinets de commande ne comportent aucune pièce
que l’utilisateur puisse réparer. Dans tous les cas de dommage ou de fonctionne ment défectueux, contacter le distributeur agréé Wells pour procéder aux réparations.
Brûleur mouillé ou trous d’al­lumage bouchés
Le bouton de commande de température n’est pas réglé
26
Nettoyer et laisser sécher le brûleur.
Régler à la température souhaitée.
Contacter un technicien qualifié pour procéder au réglage.
Page 29
PIÈCES DE RECHANGE ET SERVICE DE RÉPARATIONS
DESCRIPTION PART NO.
Pieds, réglables en métal (jeu de 4) 20563
IMPORTANT : Utiliser exclusivement des pièces de rechange et des filtres de remplacement agréés par l’usine.
Wells Bloomfield, LLC
2 Erik Circle P. O. Box 280 Verdi, NV 89439 phone: (775) 689-5707 fax: (775) 689-5976
(Service des pièces détachées)
Le Service des pièces détachées peut fournir le nom et le numéro de téléphone du distributeur agréé WELLS le plus proche de chez vous.
FRANÇAIS
RENSEIGNEMENTS À FOURNIR AU SERVICE APRÈS-VENTE
Il est recommandé d’avoir les renseignements suivants sous la main lors d’un appel pour service après-vente
RESTAURANT ________________________________ ADRESSE ________ __________________ DATE D’INSTALLATION ________________NOM DU TECHNICIEN __________________________ SOCIÉTÉ PRESTATAIRE DE SERVICES_______________________________________ _________ ADRESSE ___________________________ PROVINCE/ÉTAT ______ CODE POSTAL __________ NUMÉRO DE TÉLÉPHONE (_____)_____-_________
122 306626 OpManual for HDG-Series Griddles
NUMÉRO DE MODÈLE DE L’ÉQUIPEMENT ____________________________ NUMÉRO DE SÉRIE DE L’ÉQUIPEMENT ______________________________
COMBUSTIBLE (L'UN MARQUER) Gaz naturel Gas de pétrole liquide
27
Page 30
Genuine Parts
Protect - YOU - All - Ways
SERVICE TRAINING - QUALITY SERVICE
CUSTOMER SATISFACTION
Commercial Food Equipment Service Association
Wells Bloomfield proudly supports CFESA
Commercial Food Equipment Service Association
SERVICE TRAINING - QUALITY SERVICE
CUSTOMER SATISFACTION
WELLS BLOOMFIELD, LLC
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5703
fax: 775-689-5976
www.wellsbloomfield.com
PRINTED IN CHINA
Loading...