OPERATION
MANUAL
BUILT-IN
ELECTRIC
CHAR
162
Model B-406
This manual is considered to be part of the appliance and is to be given to the OWNER or MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
BROILERS
Models:
B406 B446 B506
includes:
INSTALLATION,
Model B-446
IMPORTANT: DO NOT DISCARD THIS MANUAL
this appliance. Additional manuals are available from your WELLS DEALER.
questions concerning installation, operation or maintenance of this equipment.
USE and CARE
p/n 2M-303673 Rev. F M162 090416 rms
LIMITED WARRANTY STATEMENT
Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser only. THIS WARRANTY IS THE COMPLETE AND ONLY WARRANTY, EXPRESSED OR IMPLIED IN LAW OR IN FACT, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND/OR FOR DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH WELLS BLOOMFIELD PRODUCTS. This warranty is void if it is determined that, upon inspection by an authorized service agency, the equipment has been modified, misused, misapplied, improperly installed, or damaged in transit or by fire, flood or act of God. It also does not apply if the serial nameplate has been removed, or if service is performed by unauthorized personnel. The prices charged by Wells Bloomfield for its products are
based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Wells Bloomfield factory authorized service agency or one of its sub-service agencies. This service will be provided on customer’s premises for non-portable models. Portable models (a device with a cord and plug) must be taken or shipped to the closest authorized service agency, transportation charges prepaid, for service. In addition to restrictions contained in this warranty, specific limitations are shown in the Service Policy and Procedure Guide. Wells Bloomfield authorized service agencies are located in principal cities. This warranty is valid in the United States and Canada and void elsewhere. Please consult your classified telephone directory, your foodservice equipment dealer or contact:
Service Department, Wells Bloomfield, LLC 10 Sunnen Drive, St. Louis, Missouri 63143
phone (314) 678-6314 or fax (314) 781-2714
for information and other details concerning warranty.
SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS
1. Resetting of safety thermostats, circuit breakers, over load protectors, and/or fuse replacements are not covered by this warranty unless warranted conditions are the cause.
2. All problems due to operation at voltages or phase other than specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage and/or phase must be the customer’s responsibility.
3. All problems due to electrical connections not made
in accordance with electrical code requirements and wiring diagrams supplied with the equipment are
not covered by this warranty.
4. Replacement of items subject to normal wear, to include such items as knobs, light bulbs; and, normal maintenance functions including adjustments of thermostats, adjustment of micro switches and replacement of fuses and indicating lights are not covered by warranty.
5. Damage to electrical cords and/or plug due to exposure to excessive heat are not covered by this warranty.
6. Full use, care, and maintenance instructions supplied with each machine. Noted maintenance and
preventative maintenance items, such as servicing and
cleaning schedules, are customer responsibility. Those miscellaneous adjustments noted are customer responsibility. Proper attention to preventative maintenance and scheduled maintenance procedures will prolong the life of the appliance.
7. Travel mileage is limited to sixty (60) miles from an Authorized Service Agency or one of its sub-service agencies.
8. All labor shall be performed during regular working hours. Overtime premium will be charged to the buyer.
9. All genuine Wells replacement parts are warranted for ninety (90) days from date of purchase on non­warranty equipment. This parts warranty is limited only to replacement of the defective part(s). Any use of
non-genuine Wells parts completely voids any
warranty.
10. Installation, labor, and job check-outs are not
considered warranty and are thus not covered by this warranty.
11. Charges incurred by delays, waiting time or operating
restrictions that hinder the service technician’s ability to perform service are not covered by warranty. This includes institutional and correctional facilities.
162 303673 OpManual for Built-In Electric Charbroilers
SHIPPING DAMAGE CLAIM PROCEDURE
NOTE: For your protection, please note that equipment in
this shipment was carefully inspected and packaged by skilled personnel before leaving the factory. Upon acceptance of this shipment, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED:
1. VISIBLE LOSS OR DAMAGE: Be certain that any visible loss or damage is noted on the freight bill or express receipt, and that the note of loss or damage is signed by the delivery person.
2. FILE CLAIM FOR DAMAGE IMMEDIATELY:
Regardless of the extent of the damage.
3. CONCEALED LOSS OR DAMAGE: if damage is unnoticed until the merchandise is unpacked, notify the transportation company or carrier immediately, and file “CONCEALED DAMAGE” claim with them. This should be done within fifteen (15) days from the date the delivery was made to you. Be sure to retain the container for inspection.
Wells Bloomfield cannot assume liability for damage or loss incurred in transit. We will, however, at your request, supply you with the necessary documents to support your claim.
xi
TABLE OF CONTENTS
WARRANTY xi SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 PRECAUTIONS & GENERAL INFORMATION 4 AGENCY LISTING INFORMATION 4 INSTALLATION 5 OPERATION 7 BROILER CHART 9 TROUBLESHOOTING SUGGESTIONS 10 CLEANING INSTRUCTIONS 11 PARTS & SERVICE 1217 WIRING DIAGRAM 1820 CUSTOMER SERVICE DATA 21
Thank you for purchasing this Wells Bloomfield appliance.
Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
This manual contains the information needed to properly install this appliance in a manner which will ensure its optimum performance.
SPECIFICATIONS
AMPS PER LEG 3ø
NEUT
MODEL ELEMENT VOLTS KW
B406
B446
B506
162 303673 OpManual for Built-In Electric Charbroilers
NOTE: Refer to appropriate Installation Instructions for equipment dimensions, cut-out dimensions, clearances, etc.
SINGLE ASSEMBLY
SINGLE ASSEMBLY
DUAL ASSEMBLIES
208 5.5 12.9 12.9 22.4 N/A 26.0 3ø 10 ga.
240 5.5 11.2 11.2 19.4 N/A 22.5
208 5.5 11.5 22.4 14.4 N/A 26.0 3ø 10 ga.
240 5.5 10.0 19.5 12.5 N/A 22.5
208 11.0 30.0 30.0 30.0 N/A - 3ø 8 ga.
240 11.0 26.0 26.0 26.0 N/A 45.0
AMPS
.
1ø 8 ga. 90 g
1ø 8 ga. 90 g
1ø 4 ga. 90g
FIELD
WIRING L1 L2 L3
1
FEATURES & OPERATING CONTROLS
ITEM
TEMPERATURE CONTROL
INDICATOR LIGHT
HEATING ELEMENT ASSEMBLY
ELEMENT GUARD / GRATE
ELEMENT SUPPORT ROD
DRIP PAN
DATA PLATE
WELLSLOKS
COMMENT
The char-broiler is INFINITE SWITCH CONTROLLED. Power is applied to the heating elements based on the control knob position and the amount of energy used.
Light will glow when the infinite switch is in any position other that OFF.
The char-broiler element assembly may be raised for cleaning, or to add water to the drip pan. It is held the “up” position by a support rod which automatically engages as the element is raised.
The grate is designed to protect the individual elements from food contact and spatula abrasion, resulting in prolonged element life and reduced carbonization. The grate is easily removed for cleaning.
IMPORTANT: Always remove the grate before lifting the element assembly.
Hold element assembly in up position. Engages automatically when the element assembly is raised.
IMPORTANT: Remember to dis-engage the support rod before lowering element assembly
The heavy-duty removable drip pan is located under the element
IMPORTANT: DO NOT pour water over elements to refill drip pan.
assembly. The drip pan catches food particles and grease drippings during broiler operation. Maintain 2 inches of water in the drip pan at all times during operation of the broiler. The drip pan is easily removed for cleaning.
Gives manufacturer, make, model and serial number. Also voltage and phase information, and agency approvals.
The broiler is equipped with WELLSLOKS, uniquely designed turnout tabs, which help secure the broiler to the countertop. (See Installation
Instructions supplied with the particular appliance for details.)
162 303673 OpManual for Built-In Electric Charbroilers
2
FEATURES & OPERATING CONTROLS (continued)
162 303673 OpManual for Built-In Electric Charbroilers
Fig. 1 Built-In Electric Charbroiler
Fig. 2 Wellsloks
3
PRECAUTIONS AND GENERAL INFORMATION
WARNING: Electric Shock Hazard
All servicing requiring access to non-insulated electrical components must be performed by a factory authorized technician. DO NOT open any access panel which require the use of tools. Failure to follow this warning can result in severe electrical shock.
CAUTION: Risk of Damage
DO NOT connect or energize this appliance until all installation instructions are read and followed. Damage to the appliance will result if these instructions are not followed.
Broilers are intended for use to cook food products for human consumption. No other use is recommended or authorized by the manufacturer or its agents.
Broilers are intended for use in commercial establishments, where all users are familiar with the appliance limitations, use and associated hazards. Operating instruction and warnings must be read and understood by all operators and users.
Do not submerge broilers in water. Do not splash, or pour water onto controls, control panels or wiring.
Disconnect the broiler from electrical power before performing any service or maintenance.
Allow drip pan to cool before removing from broiler. Do not operate broiler without the drip pan installed. Do not operate the broiler without 2” of water in the drip pan.
Any parts replacement, maintenance procedure or servicing procedure requiring the use of tools must be performed by an Authorized Service Agency.
Any troubleshooting guides, component view, parts lists or installation guides provided with this equipment are intended for the use of the qualified technical personnel only.
Except where otherwise noted, this piece of equipment is made in the USA and has American sizes on hardware.
This manual should be considered a permanent part of this appliance. This manual and all supplied instructions, diagrams, schematics, parts break downs, notices and labels must remain with the appliance if it sold or moved to another location.
162 303673 OpManual for Built-In Electric Charbroilers
AGENCY LISTING INFORMATION
This appliance conforms to NSF Standard 4 for sanitation only if
STD 4
E6070
installed in accordance with the supplied Installation Instructions.
This appliance is Underwriters Laboratory recognized ( ). Since
this appliance is only a single component of a complete installation, the
finished installation of this unit requires additional evaluations to
Underwriters Laboratory standards.
Refer to Installation Instructions included with the broiler for
Underwriters Laboratories conditions of acceptability, electrical
4
INSTALLATION
UNPACKING & INSPECTION
Carefully remove the appliance from the carton. Remove all protective plastic film, packing materials and accessories from the appliance before connecting electrical power or otherwise performing any installation procedure.
Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation.
Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding packing materials. Store all accessories in a convenient place for later use.
CUT-OUT AND INSTALLATION
Cutouts
a. Broilers may be installed in METAL COUNTERS ONLY. b. Cutout dimensions for broilers and control panels are listed on
the Installation Instructions provided with the broiler.
c. Refer to the Installation Instructions for Underwriters
Laboratories Conditions of Acceptability.
Mounting the broiler:
a. Verify that provided sealants are applied to the under side of
the broiler top flange prior to setting the unit into the cutout.
b. After installation, verify that the tabs on the Wellsloks are
turned out to lock the broiler into the counter (see Fig. 3).
c. Apply a thin bead of food-grade silicone sealant around the
flange to seal it to the counter.
Refer to the Installation Instructions for required clearances. Maintain required clearances between the appliance and adjacent combustible and non-combustible surfaces.
Sufficient overhead clearance must be provided to allow the element assembly to be raised. Refer to the Installation Instruction Sheet for required clearances.
Install drip pan and element guard/grate prior to heating or using broiler.
162 303673 OpManual for Built-In Electric Charbroilers
Avoid storing flammable or combustible materials near the appliance. This includes gasoline and other fuels, mops, rags and wrapping paper.
NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual.
IMPORTANT: This is a GENERAL GUIDE. For specific equipment and cutout dimensions, and other installation details, refer to the Installation Instructions supplied with the broilers.
Fig. 3 Set the Wellslloks
IMPORTANT: Water damage caused by failure to set Wellsloks, failure to install gasket, or failure to seal flange to counter is NOT covered by warranty.
5
INSTALLATION (continued)
WARNING: Risk of personal injury
Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical codes. Failure can result in personal injury and property damage.
CAUTION:
Electrical Shock Hazard
The broiler must be electrically grounded. Connect the terminal marked “GND” or “ ” to a suitable building ground.
IMPORTANT: Contact a licensed electrician to install and connect electrical power the broiler. Electrical installation must be performed by a licensed electrician in compliance with all local ordinances and code requirements.
IMPORTANT: Damage due to being connected to the wrong voltage or phase is
NOT covered by warranty.
ELECTRCAL HOOK-UP
Refer to the nameplate. Verify the electrical service power. Voltage and phase must match the nameplate specifications. Connecting the griddle to the wrong voltage can severely damage the unit or cause noticeable decreased performance.
Use copper wire suitable for a minimum of 90°C for electrical supply connections.
Broilers are factory wired three-phase (3ø). For single-phase (1ø) wiring, refer to the wiring diagram attached to the broiler. Conversion to 1ø must be performed by a licensed electrician.
This broiler is not fused. Protect the circuit with properly sized fuses or circuit breaker.
An electrical disconnect must be installed readily accessible to the operator of the broiler.
162 303673 OpManual for Built-In Electric Charbroilers