INSTALLATION INSTRUCTIONS
KIT# 22867
PREPARATION
1. Press power switch to OFF. Unplug warmer.
2. Drain water and remove insert pan.
3. Invert warmer. Remove BOTTOM PANEL and INSULATION.
DISASSEMBLY (See Fig. 1)
1. Detach ELEMENT CLAMPS. Swing elements out of the way.
2. Remove CONTROL KNOB by loosening set screw and pulling knob off of shaft.
3. Lift HEAT TRANSFER PLATE with TEMPERATURE CONTROL out of cabinet. Disconnect wiring from TEMPERATURE CONTROL.
4. Discard TEMPERATURE CONTROL, CONTROL KNOB and HEAT TRANSFER PLATE.
PREPARE CABINET (See Fig. 2)
1. Layout and drill 2 ea. 7/32" holes for new thermostat mounting.
Fig. 2 TEMPLATE Drill Cabinet for New Thermostat Mounting
CAUTION:
SHOCK HAZARD
Disconnect appliance from electric power before opening any access panel.
CAUTION:
BURN HAZARD
Allow appliance to cool completely before servicing.
Fig.1 Disassembly
p/n 305126 Rev. A ECN-13360 I 590 071023 cps
Page 1 of 2
Fig. 3 Install Upgrade
SERVICE PARTS
Part # Description
47158 Wiring Diagram 120VAC 47333 Wiring Diagram 240VAC 65653A Knob Control NC Med 73205 Screws, 4mm (pk of 2) 505029 Thermostat 85ÂșC NC Med 505032 505033
Heat Transfer Plate NCMed Clamp Thermobulb NCMed
INSTALL UPGRADE (See Fig. 3)
1. Set new HEAT TRANSFER PLATE in position on pan studs: a. Cutout on side of plate must clear HI-LIMIT SAFETY. b. Long end of HEAT TRANSFER PLATE goes toward the back (power cord end) of the warmer.
2. Install new THERMOSTAT: a. Terminals go toward bottom of warmer (in the inverted position, terminals will be up). b. Remove ring terminals from existing thermostat wiring and add 1/4" female spade terminals. c. Reconnect wiring to THERMOSTAT.
3. Install new CONTROL KNOB.
4. Install new THERMOBULB CLAMP: a. Set ELEMENTS in place, then set ELEMENT CLAMPS in position on pan studs. b. THERMOBULB CLAMP mounts to the forward center stud. c. Slide THERMOBULB under THERMOBULB CLAMP.
5. Reinstall and tighten all CLAMP NUTS.
6. Reinstall INSULATION and BOTTOM PANEL.
FINISH AND TEST
1. Turn warmer upright. Be sure drain valve is closed, then fill warmer with 12 quarts (11 liters) of warm water. Install insert pan.
2. Plug warmer into an appropriate receptacle. Press power switch to ON. Test for proper operation.
Procedure is complete