Wel+8010S ADSL Modem
Installation Guide
FCC Statement
FCC WARNING
This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.
INFORMATION TO THE USER
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can generate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
· Consult the dealer for technical assistance.
C ontents
Ⅰ. Installation of Wel+8010S
1.1 Basic Knowledge
1.1.1 What's the ADSL?
1.1.2 Wel+8010S ADSL Modem Specification
1.2 Wel+8010S ADSL Modem Installation
1.2.1 Confirmation of PC Installation
1.2.2 Ready for Cables
1.2.3 Connecting PC and Cable
1.2.4 Connecting LINE
1.2.5 Connecting Power
1.2.6 Connecting Console
1.2.7 Confirming Connection Status
II. Showing status of Wel+8010S
2.1 Physical status
2.2 Current configuration of Wel+8010S
2.3 System Infomation
III. Configuration of Wel+8010S
3.1 Changing Wel+8010S ADSL Mode
3.2 Establishing of HI-NET 1120 Protocol
3.2.1 RFC1483 Bridged Mode
3.2.2 RFC1483 Routed Mode (dhcpserver+NAT)
3.2.3 PPPoA Routed Mode(RFC2364/dhcpclient)
3.2.4 PPPoA Bridged Mode(RFC2364)
3.2.5 PPPoE Routed Mode(RFC2516/No using PPP client S/W)
3.2.6 IPoA Routed Mode(RFC1577/dhcpserver+NAT)
3.2.7 DHCP server
3.2.8 PPTP Tunneling
Ⅳ. Troubleshooting
4.1 Common malfunction items
4.2 About power problem
4.3 Network connection problem
Appendix A : Command words Appendix B : Webconsole Errors
I. Installation of Wel+8010S
1.1 Basic Knowledge
1.1.1 What's the ADSL?
Asymmetric Digital Subscriber Line is a technology for transmitting digital information at a high bandwidth on existing phone lines to homes and business. Unlike regular dialup phone service, ADSL provides continuously available for telephone and internet lines at the same time. ADSL is generally offered at downstream data rates from 512 kbps to about 6Mbps.
1.1.2 Wel+8010S ADSL Modem Specification
ITEM Specification
input power :110/220Vac to 5Vdc
Power
Operation
Environment
frequency : 50/60Hz
Win95/98(first,second)/2K/NT
O.S
/ME/Linux/Unix/Machintoch
Interface IEEE 802.3 10BaseT
W el+8010
(ADSL
External
Modem)
Rate(DN/UP) max 8Mbps/1Mbps
ANSI T1.413 issue2
H/W
Standard
/ITU- T G.992.1(G.dmt)
G.992.2(G.lite),G.994.1(G.hs)
Splitter Internal
LAN(LINK,ACK)/ADSL(Sync,Rx,Tx)
LED
Power&ALARM
Modulation DMT
S/W
Error Detect Reed- Soloman
Signaling PVC
Board specification size(171mmX131mmX40mm)
ADSL Line - RJ11
POTS-RJ11
Interface
Ethernet -RJ45
DC power - PC mounted DIN connector
1.2 Wel+8010S ADSL Modem Installation
1.2.1 Confirmation of PC Installation
Before connect the Wel+8010S ADSL Modem to PC, confirm that LAN card has to installed on the PC. LAN card is available in the PC shop.
1.2.2 Ready for Cables
Telephone Line Port(LINE/TEL) - RJ-11 (telephone cable 1 each) Ethernet port(LAN) - RJ-45 UTP Ethernet cable (cross cable for connection to PC directly ) CONSOLE Port - RS232-C cable
1.2.3 Connecting PC and Cable
Hook up one side of the RJ- 45 UTP Ethernet cable to the Wel+8010S ADSL Modem Ethernet port(LAN), then connect the other jack to the LAN card on the PC
1.2.4 Connecting LINE
Connect the telephone line to the LINE port of the Wel+8010S ADSL Modem
1.2.5 Connecting Power
Connect the Power Adaptor to the power input port of the Wel+8010S ADSL Modem, then hookup the power cable to the consent
1.2.6 Connecting Console Cable (For protocol setup and monitoring)
Connect HI-NET 1120 ADSL Modem's CONSOLE Port and the Serial port of the PC by the RS232- C cable then it can perform by using your favorite VT100 terminal emulation program or webconsole offered on your CD- ROM ▶ Speed -- 9600bps ▶ no parity ▶ 8 bit data ▶ 1 bit stop ▶ no flow control If you are using the Webconsole, we need not to set above items. Now you can see several lines on the screen of the terminal when you turn on the HI­NET 1120's power. This screen can be used for terminal. Also you can monitor and configure your modem Wel+8010S with webconsole offered on your CD- ROM. Webconsole is installed by “webconsole.exe ” file in offered CD-ROM with Wel+8010S. You can start the installed program by double-clicking on Wel+8010S icon in the screen.
Click on the "Serial Config” at the starting menu to set the PC COM port connected with Serial Cable.
Also The Modem can be accessed with Telnet. IP is set at 192.168.1.1 by default, which can be changed. Type "password" for password.
1.2.7 Confirming Connection Status
Each ports of the Wel+8010S ADSL Modem can be confirmed its connection status by the following methods;
Confirm the ADSL Line Connecting Status
After Wel+8010S ADSL has been connected, normally ADSL sync. LED should be blanking within some seconds. It is indicates that ADSL Line is in the status of LINK
Confirm the PC connecting Status
If LINK LED between the LAN card of the PC and Wel+8010S ADSL Modem's lights are on, it means that modem has been connected properly.
Confirm the Telephone Connecting Status
It is proper operation if you can hear normal telephone signal sound and no interruption sound when you pick up the phone, it means that the operation has been operating successfully.
※If the PWR/ALARM LED shows RED light, ADSL Modem is not in the status of
LINK or the Ethernet connecting status with PC has not been connected in properly.
II. Showing status of Wel+8010S
2.1 Physical Layer status
You can check the connecting status of the modem such as Physical Link Rate, Error count, DMT- tone by CLI(Command Line Interface)
Ø
bsp sysinfo
In using Webconsole, you can check the link status by selecting STATUS/Physical at the stating menu.
In the Physical Status screen, Selected Operation Mode shows the current setting mode from CO like DSLAM and displays Physical Link Rate and Error Count of the modem which is linked to CO. DMT- tone at the bottom part, displays each Carrier load (bits/tone) for 256 sub-channels (0~31 for
upstream, 40~255 for downstream) in graphics.
2.2 Current configuration of Wel+8010S
Using Webconsole, if you click on STATUS/Configuration you can see the current protocol setting status of the modem and IP configuration on the WAN assigned from DHCP server.
IP Configuration
which is displayed in the bottom of the Configuration Status screen shows the IP setting assigned from CO on the WAN. Therefore, any IP setting is not displayed in case that you use a Static IP.
2.3 System Infomation
Using CLI(Command Line
Interface), you can check SYSTEM information of the modem by the following commands;
Wel+8010S> chips info
Wel+8010S ADSL Modem version 7.1.0.25.2/4.6.4.1.3.5b (25 July 2001) Machine Name: Wel+8010S MAC address: 0:20:2b:0:55:20
In this version string, 7.1.0.25.2 of the front part refers to the ATMOS version of available OS, 4.6.4 refers to a bsp s/w version of the ADSL chips, and 1.3.5b refers to a firmware version of the ADSL chipset.
Using Webconsole, you can check the SYSTEM Information of the modem by selecting “STATUS”/”System info” of the starting menu.
Ⅲ. Configuration of Wel+8010S
3.1 Changing Wel+8010S ADSL Mode
Using CLI(Command Line Interface), you can select a specific ADSL Mode with the following commands.
Wel+8010S> bsp gdmt
ADSL Mode is now Gdmt (0x00000002)
Wel+8010S> config save
Saving configuration...Configuration saved.
Wel+8010S> restart
A modem is set as a Multi Mode in default. You can change the ADSL Mode using bsp glite(G.Lite), bsp ansi(T1.413) and bsp multi(Multi sensing) instead of bsp gdmt. You can confirm the Mode with the following commands.
Wel+8010S> bsp mode
ADSL Modem Mode is: gdmt (State : SHOWTIME_L0) Using Webconsole, you can change the ADSL Mode by clicking Config/ADSL Mode and
selecting the specific ADSL Mode. On ADSL Mode screen, “Modem State” shows the ADSL Sync. Status
and “Modem Mode” displays the current setting mode of the modem. If you want to change the mode to Specific Mode, select a Mode you want and click on “SAVE” button.
During the alteration of a
Configuration value in System, you can see the following screen.
If the configu ration is changed successfully, you can see the following message.
bun/port=atm/rfc1483=true/mode=llcbridged/vpi=x/vci=y
3.2 Establishing of HI-NET 1120 Protocol
3.2.1 RFC1483 bridged
Using CLI(Command Line Interface), you can change the Protocol of the modem to RFC1483 bridged mode.
On the Terminal console screen, remove the current configuration.
> config reset bridge > ip device flush > config reset ppp > config save
Saving configuration...Configuration saved.
> restart
In this way, setup for rfc1483 bridged mode is completed.
> bridge device add edd > bridge device add > config save
Saving configuration...Configuration saved.
> restart
Among the above commands, "
bridge device add edd”
the bridge.
means an add Ethernet Port on
Loading...
+ 22 hidden pages