Welite LMT1009 User Manual

OPERATION MANUAL
LMT-1009 Transmitter & LMR-400 Receiver
FEATURES:
Simple installation, easy operation
67 million codes, self program.
6 memory scene settings, no memory loss forever.
Control 2 lights (main and secondary light)
Can be controlled by transmitter and or existing house hold mechanical switch.
Security mode.
Main [I] “ON” Button
Main [I] “OFF” Button
Fig. 1
Secondary [II]“ON” Button
Secondary [II] “OFF” Button
“DELAY OFF” Button
Fig. 2 Fig. 3 Fig. 4
ON OFF ON OFF ON OFF [I] [I] [II] [II] [I]+[II] [I]+[II]
INSTALLATION: Receiver LMR-400 (Refer to Fig. 1)
z Disconnect main power before installation. z Connect AC wire (Live & Neutral) to receiver block terminal IN. z Connect Load wires into receiver block terminal OUT (Port I & Port II) . z Connect main power on.
OPERATION :
1. Transmitter LMT-1009 (Refer to Fig. 2)
z Main [I] “ON” button: Turns on main [I] light z Main [I] “OFF” button: Turns off main [I] light
(Refer to Fig. 3)
z Secondary [II] “ON” button: Turns on main [II] light z Secondary [II] “OFF” button: Turns off main [II] light
z “DELAY OFF” button: Turns off automatically after 10 seconds. z “Security mode”: Randomly turns on & off the lights.
To activate, hold both “ON and OFF” button of Main [I] for 3 seconds. To deactivate, simply press any button on the transmitter.
REMARK
In order to operate with a transmitter, the mechanical switch must be powered “ON”
2. Mechanical Switch (Refer to Fig. 4)
st
z 1
time “ON” will control the main [I] light
nd
z 2 z 3
HOW TO LINK CODE:
z To start, program transmitter with receiver. z Connect power to receiver z Switch ON first then OFF and ON cycle for 6 times, this will enter learning mode.
z Then on transmitter press the main [I] “ON” button once, main [I] and secondary [II] light will flash 2 times to indicate
time “ON” will control the secondary [II] light
rd
time “ON” will control both main [I] and secondary [II] light.
While in learning mode, the main [I] light connected to receiver will flash to indicate ready for programming.
programming is confirmed and completed.
During leaning mode if within 12 seconds no signal is detected it will automatically return to stand-by
mode.
Loading...
+ 2 hidden pages