Model No CP139, CP140 9
11 Digital Display Volts
MIG Mode (GMAW): the display will
indicate Actual weld volts.
Stick Mode (MMA): the display will indicate
the amount of Arc Force 0-10 set by Knob
(12).
Voltage Sensing (VS): the display will
indicate the weld volts setting set by Knob
(12).
12 Voltage Adjustment Knob
When in Stick MMA Mode the knob will
adjust Arc force 0-10.
When the welding machine detects a sudden
drop in the weld arc voltage, the machine
will compensate momentarily by increasing
the weld current and weld voltage.
A higher arc force might be useful for
difficult electrodes such as Cellulose.
If Weld Mode is Voltage Sensing VS the knob
will adjust the weld volts setting
13 Mode Selection Button
Pressing the button will cycle through each
of the six welding modes as indicated by the
six lights. The Six Modes are:
13.1 Stick electrode welding MMA, with
LOCAL control: The two knobs will adjust
Weld amps and Arc force.
13.2 Stick electrode welding MMA, with
REMOTE control: The two knobs will adjust
maximum Weld amps and Arc force. The
remote control will provide arc start switch
and knob control of weld amps, up to the
maximum AMPS setting.
13.3 GMAW MIG using remote wire
feeder: The weld voltage is controlled from
the wire feeder and the set value is displayed
on (11). The output voltage is only active
when signaled from the wire feeder.
13.4 TIG GTAW welding, LOCAL control:
Lift arc start, using TIG welding torch with
separate gas supply.
Knob (10) will adjust the weld current which
is displayed on (9).
13.5 TIG GTAW welding REMOTE
control: Lift arc start, using TIG welding
torch with separate gas supply.
Knob (10) will adjust the Maximum weld
current which is displayed on (9).
The remote control will provide arc start
switch and knob control of weld amps, up to
the maximum setting.
13.6 MIG Mode Voltage Sensing VS: The
Knob (12) will adjust the weld volts setting,
which is displayed on (11).
The output terminals are at full OCV. This
mode requires a special wire feeder that
is capable of operating from output live
terminals.
14 Wire select Button and Indicator
Use this button to select the wire size being
used. Sizes 0.9, 1.2, 1.6mm can be used.
When wire setting is set to Gasless then
there is no need to select wire size.
15 Gas Select button and indicator
Use this button to select which type of gas is
being used, or if Gasless wire is being used.
Ar: Argon is typically used for Aluminium
welding and Silicon Bronze welding.
Ar/He: Argon Helium is used for stainless
steel.
Ar/CO2: Is used for Argon CO2 mixed gas
There are a variety of gas mixes available.
Argon CO2 is typically used on thicker steel,
Argon CO2 O2 mix is used for thin steel.