Not recommended for pumping acid, base or organic vapors or gases.
Be sure to properly identify intake and discharge before using pump.
Welch-Ilmvac
5621 W. Howard Street
Niles, IL 60714
Phone: (847) 676-8800 (Technical Support)
Fax: (847) 677-8606
E-Mail: gdwelchvacuum@gardnerdenver.com
Web-Page: www.welchvacuum.com
Warning
Warning
See section 2.5
Part No. 642828A
Printed in USA
INSTRUCTION
WARNING AND CAUTION
PLEASE READ BEFORE OPERATION
While reading your manual, please pay close attention to areas labeled:
WARNING AND CAUTION.
The description of each is found below.
WARNING
Warnings are given where failure to observe instruction could result in
injury or death to people.
CAUTION
Cautions are found where failure to observe the instruction could result
in damage to the equipment, associated equipment and process.
These units conform to the SI International system of units of measurement.
The following symbols (with recommendation of IEC1010 ) of warning will be found on the pump.
Caution - Refer to accompanying documents
Caution - Risk of electrical shock
Caution - Hot surface
WARNING
Motor includes a self resetting thermal cutout and the pump could restart
without actuation under fault condition.
2
TABLE OF CONTENTS
Section 01 - Installation
1.01 Unpacking
1.02 Pump Mounting
1.03 Pump Location / Environmental Conditions
1.04 Exhaust Provisions
1.05 Electric Power
1.06 Vacuum Connections
1.07 Vacuum Gauges
1.08 Vacuum Pump Oil
Section 02 - Pump Features & Principles of Operation
6.17 Parts List and Exploded View
Section 07 - Specifi cations
7.20 Vacuum System for Vacuum Chamber, Glove Box, Annular Space & Transfer Line
7.21 System Components
7.22 Vacuum System for Cell Harvesting
Warranty
3
Section 1: SAFETY INFORMATION
I.10 CAUTION: To prevent injury....
I.11 Never operate this product if it has a damaged cord or plug. If it is not working properly, has
been dropped, damaged or has fallen into water, please return the product to a Welch service
center for examination and repair.
I.12 Keep the cord away from the heated surfaces.
I.13 Never block any air openings or place it on a soft surface where the openings may be blocked.
The air openings are for ventilation of the motor inside the housing. Keep all air openings free
of lint, dirt and other foreign objects.
I.14 The PTFE pump is thermally protected and can automatically restart when the protector resets.
Always disconnect power source before servicing.
I.15 Wear safety glasses or goggles when operating this product.
I.16 Use only in well ventilated areas. The motor is fan cooled enclosed in a shell.
WARNING
Do not operate the pumps in an atmosphere containing fl ammable or
explosive gases/vapors.
WARNING
Never block the exhaust port. If the exhaust is blocked, pressure will
build-up in the pump with the potential of the pump head bursting and
I.17 All electrical products generate heat. To avoid serious burns never touch unit during or
immediately after operation.
I.18 Be sure to properly identify intake and discharge before using pump. See Section II-5.
I.20 CAUTION: To reduce risk of electrical shock....
I.21 Do not disassemble. Disassembly or attempted repairs if accomplished incorrectly can create
electrical shock hazard. Refer servicing to qualifi ed service agencies only: Call (847) 676-8800
I.22 Unit is supplied with a three pronged plug. Be sure to connect pump to a properly grounded
outlet only.
I.23 WARNING: To reduce risk of electrocution…
I.24 Do not use this product in or near area where it can fall or be pulled into water or other liquids.
I.25 Do not reach for this product if it has fallen into liquid. Unplug immediately.
I.26 Never operate this product outdoors in the rain or in a wet area.
I.27 DANGER: To reduce risk of explosion or fi re…
I.28 Do not use this pump near explosive atmospheres or where aerosol (spray) products are being
used.
I.29 Do not use this product near fl ames.
causing possible injury to personnel in the area.
WARNING
Failure to observe the above safety precautions could result in severe
bodily injury, including death in extreme cases.
4
Section 2: INSTALLATION
2.10 Introduction
This manual has been compiled not only for the care and maintenance of the Welch Dry
Vacuum System now in your possession, but as a helpful reference and guide to prevent many
problems which can occur if used improperly.
2.11 Unpacking
Carefully remove the Dry Vacuum System from the shipping carton. Preserve all paperwork for
future reference. If damage has occurred from shipment a claim must be fi led with the carrier
immediately; preserve the shipping carton for inspection by the carrier. If you are required to
communicate with your dealer or Welch Vacuum be sure to include your order numbers for
quick identifi cation. Do not return the system to the factory without fi rst calling for a returned
goods number. Call (847) 676-8800.
2.12 System Mounting
Rubber feet are attached to the pump. Rubber feet are excellent for applications involving a
semi-fl exible surface such as a bench top; they help to isolate noise and eliminate creeping.
2.13 System Location and Environmental Condition
The Dry Vacuum System should be located in a clean, dry and well ventilated area. Do not to
block the ventilation ports located on the metal shell. The pump should be placed where the
surrounding temperature remains between 10°C and 40°C (50°F and 104°F). Always check
to insure the location chosen is protected from direct or indirect moisture contact. The pump
should be located as closely to its system as possible in order to utilize it most effi ciently. The
pump is rated for indoor use only. Maximum altitude 2000 meters. Operating temperature
range 5°C to 40°C. Maximum relative humidity of 80% for temp up to 31°C decreasing to 50%
at 40°C. Rated for ±10% of supply voltage. Pollution Degree2, Installation Category II.
WARNING
Don’t operate this pump in an atmosphere containing fl ammable or
The motor is thermally protected and will automatically restart
2.14 Inlet and Outlet Provisions
A inlet hose barb which accepts 3/8” I.D. hose makes it easy to connect the system to your
concentrator, rotary evaporator or gel dryer. Since the vacuum system operates in the viscous
fl ow regime, the small diameter of the hose will generate minimal conductance loss. For best
results, Welch recommends the length of the tubing between the pump and the apparatus be
kept as short as possible. Hose clamps should be used to hold the hose in place. The hose
barb in the outlet port of the pump accepts 3/8” ID hose. A vent line can be attached to the
outlet hose barb which allows gases and vapors pumped through the pump to be piped to a
fume hood. Be sure to call Welch technical service prior to start-up at (847) 676-8800 if you
have any questions.
Never Block The Outer Port. If the outlet is blocked, pressure will
buildup in the pump which can lead to the pump head bursting creating
the potential of serious injury. Remove plug from outer port.
unexpectedly when the overload device resets.
explosive gases or vapors.
WARNING
WARNING
5