Be sure to properly identify intake and exhaust before using the
pump. See Section 2.15
Do not pump liquids with the pump. Pumping liquids will cause the
pump to stop working.
Welch-Ilmvac 5621 W. Howard Street Niles, IL 60714 Phone: (847) 676-8800 (Technical Support) Fax: (847) 677-8606 E-Mail: gdwelchvacuum@gardnerdenver.com Web-Page: www.welchvacuum.com
WARNING
CAUTION
Part No. 642779
Printed in USA
INSTRUCTION
WARNING AND CAUTION
PLEASE READ BEFORE OPERATION
While reading your manual, please pay close attention to areas labeled:
WARNING AND CAUTION.
The description of each is found below.
WARNING
Warnings are given where failure to observe instruction could
result in injury or death to people.
CAUTION
Cautions are found where failure to observe the instruction could
result in damage to the equipment, associated equipment and
process.
These units conform to the SI International system of units of measurement.
The following symbols (with recommendation of IEC1010 ) of warning will be found on the pump.
Caution - Refer to accompanying documents
Caution - Risk of electrical shock
Caution - Hot surface
WARNING
Motor includes a self resetting thermal cutout and the pump could
restart without actuation under fault condition.
TABLE OF CONTENTS
Section Page Section 01 - Safety Information
1.10 Caution: to prevent injury 4
1.20 Caution: to reduce risk of electrical shock 4
1.30 Warning: to reduce risk of electrocution 5
1.40 Warning: to reduce risk of explosion or fi re 5 Section 02 - Installation
2.10 Environmental conditions 6
2.11 Introduction 6
2.12 Unpacking 6
2.13 Pump mounting 6
2.14 Pump location 6
2.15 Discharge provisions 7
2.16 Electrical power 8
2.17 Advanced Vapor Management (AVM) 8
2.18 Traps 8
2.19 The care of a liquid trap 9
2.20 The care of a cold trap 9 Section 03 - Operation
3.10 Starting a Welch DRY Vacuum Pump 10
3.11 Cleanliness 10
3.12 Leak detection 10
3.13 Operating pressure range 10
3.14 The effects of unwanted vapor 10
3.15 Shutdown procedure 10 Section 04 - Maintenance
4.10 General maintenance 11
4.11 Diaphragm removal 11
4.12 Installation of new diaphragm 11 Section 05 - Application
5.10 Operation as a replacement for aspirators 12
5.20 Cross reference Welch DRY Pump to Water Aspirator 12 Section 06 - Specifi cations
6.10 Specication Chart 13 Section 07 - Specifi cations
Warranty 14 Section 08 - Drawings
8.10 Dimensional drawing 15
8.20 Exploded view and kit for 2034, 2037 & 2044 16
8.30 Exploded view and kit for 2014, 2032, 2042 & 2047 17 3
Section 1: SAFETY INFORMATION
1.10 Caution: To Prevent Injury...
1.11 Never operate this product if it has a damaged cord or plug. If it is not working properly, has
been dropped, damaged or has fallen into water, please return the product to a Welch service center for examination and repair.
1.12 Keep the cord away from heated surfaces. All electrical products generate heat. To avoid
serious burns never touch unit during or immediately after operation.
1.13 Never block any air openings or place it on a soft surface where the openings may be blocked.
To ensure proper ventilation, keep unit a minimum of one inch from any wall or obstruction. The air openings are for ventilation of the motor inside the housing.
1.14 Models 2014, 2032, 2034, 2037, 2042, 2044 and 2047 are thermally protected and can
automatically restart when the protector resets. Always disconnect power source before servicing.
1.15 Never drop or insert fi ngers or any other object into any openings.
1.16 Do not operate this product where oxygen is being administered.
1.17 Wear safety glasses and goggles when operating this product.
1.18 Use only in well ventilated areas. The motor on all pumps are totally enclosed fan cooled
WARNING
Do not operate the pumps in an atmosphere containing fl ammable or
explosive gases/vapors
1.19 Be sure to properly identify intake and discharge before using pump. See Section 2.5.
Models 2014, 2032, 2034, 2037, 2042, 2044 and 2047 have one exhaust port on the pump.
See Section 2.15.
WARNING
Remove plug from Exhaust Port before using
1.20 Caution: To Reduce Risk Of Electrical Shock...
1.21 Do not disassemble. Disassembly or attempted repairs if accomplished incorrectly can create
electrical shock hazard. Refer servicing to qualifi ed service agencies only.
1.22 Unit is supplied with a three pronged plug. Be sure to connect pump to a properly grounded
outlet only.
1.30 Warning: To Reduce Risk of Electrocution...
1.31 Do not use this product in or near area where it can fall or be pulled into water or other liquids.
1.32 Do not reach for this product if it has fallen into liquid. Unplug immediately.
1.33 Never operate this product outdoors in the rain or in a wet area.
1.40 Danger: To Reduce Risk of Explosion or Fire...
1.41 Do not use this pump in or near explosive atmospheres or where aerosol (spray) products are
being used.
1.42 Do not use this product near fl ames.
WARNING
Failure to observe the above safety precautions could result in Severe
bodily injury, including death in some cases
Section 2: INSTALLATION
2.10 Environmental Conditions
The Pump is rated for indoor use only. Maximum altitude 2000 meters. Operating temperature
o
range 10 to 50% at 40oC. Rated for +/-10% of supply voltage. Pollution Degree 2, Installation Category II.
2.11 Introduction
This manual has been compiled not only for the care and maintenance of the Welch Dryfast
Vacuum pump now in your possession, but as a helpful reference and guide to prevent many problems which can occur if used improperly.
2.12 Unpacking
Carefully remove the Dryfast Vacuum pump from the shipping case. Preserve all paperwork for
future reference. If damage has occurred from shipment a claim must be fi led with the carrier immediately; preserve the shipping carton for inspection by the carrier. If you are required to communicate with your dealer or Welch Vacuum be sure to include your order numbers for quick identifi cation. Do not return the pump to the factory without obtaining returned goods authorization. *See “Service & Support” on www.welchvacuum.com.
C to 40oC. Maximum relative humidity of 80% for temperatures up to 31oC decreasing
2.13 Pump Mounting
Rubber feet are attached to the pump casing.
2.14 Pump Location
WARNING
Don’t operate this pump in an atmosphere containing fl ammable or
explosive gas
WARNING
The motor is thermally protected and will automatically restart
unexpectedly when the overload device resets
The Dryfast Vacuum pump should be located preferably in a clean, dry and well ventilated
area. Please be sure not to block the ventilation ports located on the motor housing. The pump
o
should be placed where the surrounding temperature remains between 10 and 104
o
F). Always check to insure the location chosen is protected from direct or indirect
C and 40oC (50oF