Welch Allyn Medical Diagnostic Equipment User Manual
SureTemp® Plus
REF 690 and 692
Printed in Mexico.
US
C
166292
N344
WELCH ALLYN PTY LTD
5/38-46 SOUTH STREET
RYDALMERE
NSW 2116
AUSTRALIA
U.S. Patent 5,632,555; 6,000,846; 6,036,361; 6,971,790. Additional U.S. and
foreign patents pending.
AGENCY APPROVALS
CERTIFIED TO: CAN/CSA STD C22.2 NO. 601.1
CONFORMS TO: IEC 60601-1, 60601-1-2, UL STD 2601-1
EMC Framework of Australia
The CE mark on this product indicates that the product has
been tested to and conforms with the provisions noted
within the 93/42/EEC Medical Device Directive.
Authorized European Representative Address:
European Regulatory Manager
Welch Allyn Ltd.
Navan Business Park
Dublin Road
Navan, County Meath
Republic of Ireland
Tel: + 353 46 90 67700
Fax:+ 353 46 90 67755
®
CaviCide
is a registered trademark of Metrex Research Corporation
2008 by Welch Allyn, Inc. All rights reserved. No part of this manual may be
reproduced or transmitted in any form or by any means, electronic or mechanical,
including photocopy, without prior written consent from Welch Allyn.
ATTENTION: Caution consult user’s manual for additional
information.
Type BF Applied Part
Handle with Care
Transport/Storage Temperature
MAX
Transport/Storage Humidity
Internally Powered Alkaline Battery - AA 1.5V
IPXØNot protected against the ingress of water.
Latex Free
Do not dispose of this product as unsorted municipal waste.
Prepare this product for reuse or separate collection as
specified by Directive 2002/96/EC of the European
Parliament and the Council of the European Union on Waste
Electronic and Electrical Equipment (WEEE). If this product
is contaminated, this directive does not apply.
For more specific disposal information, see
www.welchallyn.com/weee, or contact Welch Allyn
Customer Service at +44 207 365 6780.
1
SAFETY AND WARNINGS
In order to obtain accurate and reliable temperature results and
ensure patient safety, it is important that this booklet is read
thoroughly prior to using the instrument. If you have any technical
or clinical questions concerning the thermometer’s use and/or
care, please contact the Welch Allyn Customer Service
Department.
Use single-use Welch Allyn disposable probe covers to limit
patient cross-contamination. The use of any other probe cover
may produce temperature measurement errors or result in
inaccurate readings.
Do not take a patient’s temperature without using a Welch Allyn
disposable probe cover. Doing so can cause patient discomfort,
patient cross contamination, and erroneous temperature
readings.
Long-term continuous monitoring beyond three to five minutes is
not recommended in any mode.
Biting the probe tip while taking a temperature may result in
damage to the probe.
Oral/axillary probes (blue ejection button at top of probe) and blue
oral/axillary removable probe wells are used for taking oral and
axillary temperatures only. Rectal probes (red ejection button) and
red rectal removable probe wells are used for taking rectal
temperatures only. Use of the probe at the wrong site will result
in temperature errors. Use of the incorrect removable probe well
could result in patient cross contamination.
To ensure patient safety and temperature measurement accuracy,
use only accessories and supplies recommended or supplied by
Welch All yn.
Equipment is not suitable for use in the presence of a flammable
anesthetic mixture with air or with oxygen or nitrous oxide.
The thermometer case, connectors, and probe are not
waterproof. Do not immerse or drip fluids on these items. Should
this occur, dry the device with warm air. Check all operating
functions for proper operation.
2
Do not take an axillary temperature through patient’s clothing.
Direct probe cover to skin contact is required.
The Welch Allyn SureTemp Plus thermometer consists of high
quality precision parts. Protect it from severe impact and shock. A
qualified service technician must check any SureTemp Plus
thermometer which is dropped or damaged to ensure proper
operation prior to further use. Do not use the thermometer if you
notice any signs of damage to the probe or instrument. Contact
the Welch Allyn Customer Service Department for assistance.
Welch Allyn recommends that batteries are removed for long term
storage since alkaline batteries can deteriorate and leak over
extended periods of time, and possibly cause damage to the
thermometer.
Do not autoclave. Please note the cleaning procedures described
on page 21 of this manual.
Do not use this instrument for any purpose other than that
specified in this booklet. Doing so will invalidate the instrument’s
warranty.
This thermometer complies with current required standards for
electromagnetic interference and should not present a problem to
other equipment nor is it effected by other devices. As a
precaution, avoid using this device in close proximity to other
equipment.
3
INTRODUCTION
Congratulations on your purchase of the Welch Allyn SureTemp Plus Thermistor
Thermometer. Please follow the operating and maintenance instructions provided
in this manual to ensure years of accurate and reliable service. Please read these
instructions thoroughly before using the instrument, and then store these
instructions in a safe place for future reference.
The Welch Allyn SureTemp Plus is a portable thermistor thermometer
used for accurately measuring body temperatures at oral, axillary, or
rectal sites.
Normal body temperature is a range, which varies from person to person
and is influenced by factors such as time of day and an individual’s level of
activity, ingested medications, age, and gender. A person’s normal
temperature tends to decrease with age.
The following table shows that ranges of normal also vary by site. Do not
directly compare measurements from different sites.
This booklet provides informative tips and instructions for using the
SureTemp Plus model 690 and model 692 thermometers. The chart on
the following page provides details about the differences between these
SureTemp Plus instruments.
4
SURETEMP PLUS MODEL COMPARISON CHART
This manual describes features found in SureTemp Plus model 690 and 692
thermometers. Certain features are not available to users of the model 690
thermometer.
SureTemp Plus
Model 690
Probe Cover StorageXX
F/C ConversionXX
Last Temperature RecallXX
Monitor ModeXX
Detachable ProbeXX
Oral / Axillary / Rectal
Modes on Each
Thermometer
Color-Coded Removable
Probe Well
Wall-Holder StandardX
Pulse TimerX
BacklightX
Security (Electronic)X
Configurable On-Screen
Labeling for
Identification of
Instrument
XX
XX
SureTemp Plus
Model 692
X
Sold in U.S./CanadaXX
Sold InternationallyXX
Instrument Warranty2 years3 years
Removable Probe Well90 days90 days
Probe Warranty1 year1 year
5
INDICATIONS/CONTRAINDICATIONS
Thermometer
LCD Display
Probe
Ejection Button (blue or red)
Removable Probe Well (blue or red)
Latching Probe Connector
Battery Door/Probe Cover
Storage Compartment
C/F (Celcius/
Fahrenheit) Button
Pulse Timer Button
(692 Only)
Mode Selection
Button
Recall Button
Box of Probe Covers
The Welch Allyn SureTemp Plus thermometer measures patient’s temperature in
the oral, axillary, and rectal body sites of adult, pediatric, and newborn patients.
The device is not designed, sold, or intended for use except as indicated.
PARTS AND FEATURES
You can find the serial number of your device on a label affixed to the rear housing
inside the unit’s probe cover storage compartment. Please note the parts of your
Welch Allyn SureTemp Plus thermometer as shown below:
6