Weishaupt WTC 15-A, WTC 25-A, WTC 32-A Operating Instructions Manual

Operating instructions Weishaupt Thermo Condens
WTC 15-A WTC 25-A WTC 32-A
Address of installer
Max Weishaupt GmbH 88475 Schwendi, Germany Te l. +49 (73 53) 83-0 Fax +49 (73 53) 83-358 www.weishaupt.de
Print-No. 83053102, December 2006 Printed in Germany. All rigths reserved.
1/2006 GB
Gas inhalation can lead to suffocation or poisoning, depending on the type and quantity of gas inhaled. There is a risk of explosion if an ignition source is present.
Safety measures when gas can be smelled:
1. Avoid open flames and spark generation (e.g. switching lights and electric units on and off, including the use of mobile phones).
2. Close gas shut off valve.
3. Open windows and doors.
4. Warn all occupants and evacuate the building.
5. Inform heating company/installer and gas supplier from outside of the building.
Risks of poisoning!
Blocked air inlets can lead to the formation of toxic Carbon Monoxide. Keep air inlets/outlets in the installation area open.
When flue gas can be smelled:
1. Turn off the equipment.
2. Open doors and windows.
3. Alert the heating company/installer.
Installation area
Unsuitable ambient conditions may damage the equipment. For safe, reliable operation ensure that
the installation area is well ventilated and dust free for
room air dependant operation,
•the combustion air does not contains Halogen Hydrocarbons
(such as in sprays, solvents, washing or cleaning products).
Working on the heating system
Improperly carried out work on the heating system can result in serious injury. Installation, commissioning, adjusting, servicing and repairs must only be carried out by qualified personnel.
Fuel
The condensing boiler may only be operated with the types of gases given on the name plate.
For your safety
2 15
Chimney sweep function
• Activate the symbol list by turning the dial knob and set cursor to chimney sweep symbol.
• Press key to activate chimney sweep function.
•The function remains active for 15 minutes.
•The 3 larger numbers displayed show the current rating of the boiler.
•The 2 smaller numbers displayed show the current boiler temperature.
•To exit the chimney sweep functions turn dial knob until ESC is displayed and press key.
•After approximately 90 seconds, the standard display reappears.
90 secs.
Regular servicing saves energy and protects the environment
The complete heating system should be serviced at least once a year by a representative of the heating company/installer or other
qualified engineer.
We recommend a Weishaupt service contract be taken out.
3
Contents
Commissioning 4
Boiler shut down 5
What to do should problems occur 6
Operating the controller 7
Operating levels 8
Half-yearly inspection 12
Chimney sweep function 15
14
Half-yearly inspection:
For room air dependent operation only!
Inlet air must be open!