Installation and operating instruction
Translation of original
operating instructions
Room device WEM-RG2
1 User instructions
1 User instructions
This manual forms part of the equipment and must be kept on site.
Carefully read the manual prior to working on the unit.
It is supplemented by the installation and operating instructions for the condensing
unit.
1.1 Target group
The manual is intended for the operator and qualified personnel. They should be
observed by all personnel working with the unit.
Work on the unit must only be carried out by personnel who have the relevant training and instruction.
In accordance with EN 60335-1 the following requirements apply
This appliance can be used by children 8 years and above as well as by persons
with limited physical, sensory or mental capacities or lack of experience and knowledge, provided they are supervised or have been instructed regarding the safe use
of the appliance and understand the resulting danger. Children must not play with
the appliance. Cleaning and operator maintenance must not be carried out by children without supervision.
1.2 Symbols
DANGER
WARNING
CAUTION
…Range of values
Immediate danger with high risk.
Non observance can lead to serious injury or death.
Danger with medium risk.
Non observance can lead to environmental damage,
serious injury or death.
Danger with low risk.
Non observance can cause damage to the equipment and injury to personnel.
Important information
Requires direct action
Result after an action
Itemisation
83307102 2/2017-11 La
3-28
Page 4
1 User instructions
Installation and operating instruction
Room device WEM-RG2
1.3 Guarantee and Liability
Guarantee and liability claims for personal and equipment damage are excluded, if
they can be attributed to one or more of the following causes:
non approved application,
non-observance of the manual,
operation with faulty safety equipment,
continual operation despite a fault,
improper installation, commissioning, operation and service,
repairs, which have been carried out incorrectly,
the use of non original Weishaupt parts,
force majeure,
the installation of additional components, which have not been tested with the
unit.
83307102 2/2017-11 La
4-28
Page 5
Installation and operating instruction
Room device WEM-RG2
2 Safety
2 Safety
2.1 Designated application
The room device in conjunction with the Weishaupt Energy ManagementWEM is
suitable for:
the operation of up to 3 heating circuits,
the operation of a DHW circuit.
The unit should only be used in enclosed rooms.
The installation location must comply with local regulations and must be frost-proof.
Improper use could:
endanger the health and safety of the user or third parties,
cause damage to the unit or other material assets.
2.2 Safety measures
Safety relevant fault conditions must be eliminated immediately.
2.3 Disposal
Dispose of all materials and components in a safe and environmentally friendly way
at an authorised location. Observe local regulations.
83307102 2/2017-11 La
5-28
Page 6
3 Product description
160 mm
100 mm
Installation and operating instruction
Room device WEM-RG2
3 Product description
3.1 Type key
WEM-RG2 …
WEMType: Weishaupt Energy Management
RG2Type: room device comfort version
…Version
3.2 Technical data
3.2.1 Electrical data
Voltage supplyDC 15 … 26 V
Consumptionmax 0.7 W
Type of protectionIP 20
3.2.2 Ambient conditions
Temperature in operation0... +50°C
Temperature during transport / storage0... +50°C
relative humiditymax 85%, no dew point
3.2.3 Dimensions
83307102 2/2017-11 La
6-28
Page 7
Installation and operating instruction
1
Room device WEM-RG2
4 Installation
4 Installation
Remove room device from wall bracket
Place a suitable screwdriver into the recess1 and disengage the room device
in the direction of the arrow.
Remove room device.
Pull off protective foil
Pull off protective foil.
83307102 2/2017-11 La
7-28
Page 8
4 Installation
WEM-FA-G
H L – +
H L – +
2
1
3
DANGER
Installation and operating instruction
Room device WEM-RG2
Fit wall bracket and connect
Risk of electric shock
Working on the device when voltage is applied can lead to electric shock.
Isolate the device from the power supply prior to starting any work.
Safeguard against accidental restart.
The electrical connection must only be carried out by qualified electricians. Observe local regulations.
If only 2 wires are available on site, the connection can be made using the
adapter set WEM-CAN 2 wire (RG2) (accessory).
Secure wall bracket1 to the wall using the screws supplied.
Feed the wires2 through and connect to wiring diagram.
Hook in the room device at the top of the wall bracket3 and push to engage.
83307102 2/2017-11 La
8-28
Page 9
Installation and operating instruction
2
1
Room device WEM-RG2
5 Operation
5.1 Display and operating unit
5 Operation
1 Dial knobturnnavigation through parameter structure;
changing values
pressbriefly: confirm or save values
approx. 3seconds: exit value without saving
approx. 5seconds: return to the start screen
Installation and operating instruction
Room device WEM-RG2
5.2 Display
Start screen
1 Current heating circuit being accessed
(heating circuit assigned to HC operating access 1 ).
2 Information:
Information from menu Info in the user level.
The 2 fields can be assigned as required [ch.5.4.1].
3 Current status of the operating mode of the heating circuit shown.
4 Level selection:
Favourites level
User level
Operating mode
Room setpoint temperature
The dial knob is used to select the level.
5 Current time program of the heating circuit shown.
6 Current operating mode of heating circuit shown.
7 Current room temperature.
Symbols
Favourites level / Create favourite
User level
Operating mode
Room setpoint temperature
Exit display
Information /Help text
83307102 2/2017-11 La
10-28
Page 11
Installation and operating instruction
Example
16:552016-06-23
Thursday
Burner control 1
Fault 21
No flame formation at burner start
Heating circuit 1
16:552016-06-23
Thursday
Room device 2 1
Warning 1
Humidity in room too high
Heating circuit 1
16:552016-06-23
Thursday
Burner control 1
Info 1
Service note
Heating circuit 1
Room device WEM-RG2
5 Operation
Lockout
The room device detects irregularities in the system and displays them.
Note down display and inform your heating engineer or Weishaupt's customer
service.
Service
If the service interval of the condensing unit is exceeded, a message appears in the
display.
Notify your heating contractor or Weishaupt Customer Service.
83307102 2/2017-11 La
11-28
Page 12
5 Operation
Time program 1Normal
23.5
Room temperature
16:552016-06-23
Thursday
50 °C
7 °C
°C
036912151821 24
Heating circuit 1
Favourites
Operating
mode
Room
setpoint
temperature
Party/
Heating pause
HeatingprogramsHoliday
DHW
Push
111
111
DHW setpoint temperature
Normal
Setback
50 °C
40 °C
Replace which favourite?
OK = press | ESC = press 3 secs.
Operating
mode
Room
setpoint
temperature
Party/
Heating pause
HeatingprogramsHoliday
DHW
Push
111
111
Installation and operating instruction
Room device WEM-RG2
5.3 Favourites level
Frequently used user level parameters can be assigned as favourites.
It is possible to assign a maximum of 6favourites. Factory pre-assigned favourites
can be replaced by parameters from the user level.
Display favourites
Select Favourites level using dial knob and confirm.
Display changes to Favourites level.
Assigning favourites
Select the desired parameter in the user level.
Select and confirm.
Turn the knob to select an existing favourite and replace by confirming.
A new favourite has been assigned.
83307102 2/2017-11 La
12-28
Page 13
Installation and operating instruction
User
InfoHeating circuit
Domestic hot
water
Statistic
Time program 1Normal
23.5
Room temperature
16:552016-06-23
Thursday
50 °C
7 °C
°C
036912151821 24
Heating circuit 1
Settings
Room device WEM-RG2
5 Operation
5.4 User level
Select User level using dial knob and confirm.
Display changes to the User level.
Depending on the execution, hydraulics and control variations, certain information
and parameters are hidden.
83307102 2/2017-11 La
13-28
Page 14
Installation and operating instruction
Info
Room device WEM-RG2
5 Operation
5.4.1 Info
In menu Info, the information is read only.
InformationDescription
External temperature
DHW
temperature
DHW
Actual outlet temperature
DHW
Flow rate
Return flow temperature
Circulation
Room temperatureCurrent temperature at the room device.
Current temperature at the external sensor.
Current temperature at the DHW sensor.
Current temperature at the DHW outlet sensor (versionC).
Current DHW flow rate at the water flow sensor of the condensing unit (version
C).
Current temperature at the return flow sensor of the circulation line.
Room humidityCurrent room humidity at the room device.
Flow temperatureCurrent temperature at the flow sensor of the corresponding heating circuit.
Collector outputCurrent heat output of the solar system.
Collector
Current temperature at the collector sensor.
temperature
Storage tank tem-
Current temperature at the bottom of the storage tank.
perature
bottom
RatingCurrent heating capacity of the condensing unit.
Boiler temperature Current temperature at the flow sensor of the condensing unit.
System pressureCurrent system pressure.
Buffer storage
Current temperature at the buffer sensor at the top.
temperature top
Buffer storage
Current temperature at the buffer sensor at the bottom.
temperature bottom
De-couple temper-
Current temperature at de-couple sensor.
ature
Plate heat
Current temperature at the plate heat exchanger.
exchanger temperature
Device information Current device information (Software version, etc.).
Assignment RG2Current assignment of room device.
83307102 2/2017-11 La
14-28
Page 15
Installation and operating instruction
Room device WEM-RG2
The following information can be displayed on the start screen [ch.5.2].
Select information required and confirm.
Select and confirm Info on start screen?.
Select information, which is to be replaced and confirm.
Information on start screen is replaced.
5 Operation
83307102 2/2017-11 La
15-28
Page 16
Installation and operating instruction
Heating circuit
Operating
mode
Heatingprograms
Party/
Heating pause
Room device WEM-RG2
5 Operation
5.4.2 Heating circuit
If operating access was assigned to multiple heating circuits, a separate menu appears for each heating circuit.
Parameters Setting
determines the type of operation of the heating circuit.
If functions (heating, DHW) are deactivated in menu System operating mode , the setting has
no effect.
Standby:
Frost protection on
Heating off
DHW off
Time program 1 … 3:
Frost protection on
Heating on
Temperature level according to selected time program. Time programs can be set in parameter
Heating program .
DHW on
(Factory setting: Time program 1)
Summer:
Frost protection on
Heating off
DHW on
Comfort, Normal, Setback:
Frost protection on
Heating on
Temperature level according to the operating mode set, independent of the time program.
DHW on
The heating program is used to stipulate the times of the day when comfort, normal or setback heating
is used.
Time program 1 … 3
The preset time programs can be customised.
Changing a time program:
Select time program using the knob and confirm.
Time bars are displayed.
Select week day(s) using the knob and confirm.
Time program can be edited.
The temperature of the level can be set using parameter Room setpoint temperature.
Set time program required in parameter Operating mode .
The temperature level of the heating program can be temporarily changed (maximum23:45hours).
After this time the current heating program will be reactivated.
Select Function and set Party/Heating pause .
Set level required in Room setpoint temperature .
Enter Start and End.
If the parameter is set to Off, the current heating program is activated.
(1
Factory setting and setting range depending on heating circuit set, see installation and operating manual for con-
densing unit.
83307102 2/2017-11 La
16-28
Page 17
Installation and operating instruction
Room
setpoint
temperature
Flow setpointtemperature
Special
level
Holiday
Heating curve
Su/Wi
change-over
Room device WEM-RG2
5 Operation
Parameters Setting
Room setpoint temperature for the temperature level selected.
Comfort (factory setting: 22.0 °C)
Normal (factory setting: 21.0 °C)
Setback (factory setting: 16.0 °C)
The levels can be assigned to specific times of the day using parameter Heating program .
Flow setpoint temperature for the temperature level selected.
Comfort
Normal
Setback
(1
(1
(1
The levels can be assigned to specific times of the day using parameter Heating program .
Only if control variation Constant flow temperature has been set on the system device
[ch.6.1.1].
Defines the flow temperature set at special level. The heating program is not effective.
When inputH1 is closed, the system heats up to the special flow level set.
Only if input H1 of the system device has been configured to Heating circuit1: Special
level .
Interrupt heating program for a certain period of time. The level can be set to Setback or Frost
during this time.
Set Function to On.
Set Room setpoint temperature to Setback or Frost.
Enter Start date and End date.
If the parameter is set to Off, the current heating program is activated.
Flow setpoint temperature dependent on external temperature [ch.6.1.2].
The display refers to the room setpoint temperature Normal.
The heating curve gradient can be changed and / or it can be moved in parallel.
Gradient
Parallel movement
(1
(1
Adapting the heating curve [ch.6.1.2]:
cold external temperature: change gradient
mild external temperature: change parallel movement
Only if control variation Weather compensated control or Weather compensated /
room control has been set on the system device.
On (factory setting):
If the damped external temperature (tendentious course) exceeds the value set (factory setting:19°C), the operating mode changes to Summer.
Off:
The operating mode set remains activated, independent of the external temperature.
(1
Factory setting and setting range depending on heating circuit set, see installation and operating manual for con-
densing unit.
83307102 2/2017-11 La
17-28
Page 18
5 Operation
Domestic hot
water
DHW setpoint
temperature
DHW
Push
DHW
program
Circulation
program
DHW
operating
mode
Parameters Setting
DHW temperature for normal and setback operation.
Normal (factory setting: 50 °C)
Setback (factory setting: 40 °C)
Normal and setback operation can be assigned to specific times of the day using the DHW program.
With versionC only the DHW setpoint temperature for normal operation is displayed.
DHW Push is used to cover increased hot water demand, e.g. during setback operation.
The DHW tank is heated once to the DHW setpoint temperature set for normal operation.
The DHW program is used to stipulate the times of the day when the DHW tanks is heated to normal
temperature or setback temperature.
For version C, the plate heat exchanger is brought to and maintained at the DHW setpoint tem-perature during normal operation (comfort mode). As a result, hot water is available immediately.
Change a time program:
Select week day(s) using the knob and confirm.
Time program can be edited.
The circulation program is used to stipulate the time of day when the circulation pump is switched on.
The time program can be adapted individually.
Change a time program:
Select week day(s) using the knob and confirm.
Time program can be edited.
Deactivate DHW preparation.
On (factory setting):
DHW preparation activated.
Off:
DHW preparation deactivated.
Installation and operating instruction
Room device WEM-RG2
5.4.3 Domestic hot water
83307102 2/2017-11 La
18-28
Page 19
Statistic
Information Description
Energy WTC
Total
Energy
Solar
Recooling
Solar
Total amount of heat generated by the condensing unit.
Solar system yield.
Yield for re-cooling via collector circuit.
Installation and operating instruction
Room device WEM-RG2
5 Operation
5.4.4 Statistic
In the Statistic menu, daily, monthly and annual values relating to the energy
generated are displayed.
83307102 2/2017-11 La
19-28
Page 20
5 Operation
Settings
Language
Brightness
Night mode
Humidity in
the room
Light ring
Correction
room sensor
Parameters Setting
Set language.
Adjust the brightness of the display.
Automatic (factory setting):
The brightness of the display is regulated depending on the brightness of the room.
Manually:
The brightness can be adjusted from 10 … 100 %.
Off (factory setting):
If the display is in standby, the current room temperature, date and time are displayed.
On:
The display is completely switched off in standby mode during the time set.
Monitors the humidity in the room.
Min. value
Max. value
If the humidity in the room exceeds the limits, a warning message appears.
Note:
The optimum humidity in living areas is 40 ... 60%.
Configuring the light ring on the room device.
Off:
Light ring is always off.
Operation (factory setting):
light ring is only illuminated, when the display is activated.
On:
light ring is illuminated, when the display is activated or a fault message is present.
Correction of the current room temperature.
If no optimal placement of the room sensor is possible or a measurement error is to be compensated,
the measured room temperature can be corrected.
Installation and operating instruction
Room device WEM-RG2
5.4.5 Settings
83307102 2/2017-11 La
20-28
Page 21
Installation and operating instruction
Time program 1Normal
23.5
Room temperature
16:552016-06-23
Thursday
50 °C
7 °C
°C
036912151821 24
Operating mode
Time program 1
Frost protection on
Heating on
DHW on
1
Heating circuit 1
Room device WEM-RG2
5 Operation
5.5 Operating mode
Determines the operating mode of the heating circuit.
The heating circuit assigned is shown in the display above with the corresponding
number. The assignment can be changed on the system device in menu Commis-sioning → device list.
If functions (frost protection, heating, DHW) are deactivated at the system device in
menu System operating mode, the setting has no effect.
Standby:
Frost protection on
Heating off
DHW off
Time program 1 … 3:
Frost protection on
Heating on
Heating level according to the time program selected. Time programs can be set
in parameter Heating program .
DHW on
(Factory setting: Time program 1)
Summer:
Frost protection on
Heating off
DHW on
Comfort, Normal, Setback:
Frost protection on
Heating on
Heating level according to the operating mode set, independent of the time pro-
gram.
DHW on
Select the operating mode with the knob and confirm.
Display changes to the setting of the operating mode.
83307102 2/2017-11 La
21-28
Page 22
5 Operation
Time program 1Normal
23.5
Room temperature
16:552016-06-23
Thursday
50 °C
7 °C
°C
036912151821 24
Heating circuit 1
Room setpoint temperature
1
Comfort
Normal
22.0 °C
21.0 °C
Setback
16.0 °C
Installation and operating instruction
Room device WEM-RG2
5.6 Room setpoint temperature
Stipulates the room setpoint temperature for the temperature level selected.
Comfort (factory setting: 22.0 °C)
Normal (factory setting: 21.0 °C)
Setback (factory setting: 16.0 °C)
Select the room setpoint temperature with the knob and confirm.
Display changes to the the setting of the room setpoint temperature.
The levels can be assigned to specific times of the day using parameter Heatingprogram .
If the Room setpoint temperature is changed, the heating curve is automatically adapted.
83307102 2/2017-11 La
22-28
Page 23
Installation and operating instruction
Room device WEM-RG2
6 Technical documentation
6 Technical documentation
6.1 Control options
6.1.1 Constant flow temperature
No additional sensors or thermostats are required for this control.
The flow temperature from the heating circuit is controlled to the flow setpoint tem-
perature set in the user level, see [ch.5.4.2].
Room frost protection and setting optimisation are not active.
6.1.2 Weather compensated control
The flow temperature is controlled depending on the external temperature.
An external sensor is required for weather compensated control.
Mount the external sensor to the north side or the north-west side of the build-
ing, half way up (min 2.5 m).
Avoid direct solar radiation and heat up by external heat sources at the external
sensor.
The current flow temperature setpoint is calculated from:
external temperature,
Heating curve:
Gradient,
Parallel movement,
Room setpoint temperature.
A higher flow temperature is required to achieve the desired room temperature,
when external temperatures are lower. The gradient determines how much the
change in external temperature affects the flow setpoint temperature and adjusts
the heating curve to the building.
The heating curve can be moved vertically using the parallel movement.
Room temperature too coldRoom temperature too warm
Decrease room setpoint temperature
– or –
decrease parallel movement.
83307102 2/2017-11 La
The heating curve and the room setpoint temperature can be set in the user level
[ch.5.4.2].
23-28
Page 24
6 Technical documentation
Installation and operating instruction
Room device WEM-RG2
6.1.3 Room temperature dependent control
The flow temperature is controlled depending on the room temperature.
A room device or room sensor are required for room temperature dependent con-
trol.
Avoid direct solar radiation and heat up by external heat sources at the room
sensor.
The current flow temperature setpoint is calculated from:
room setpoint temperature,
current room temperature,
room sensor influence.
The room setpoint temperature can be set in the user level [ch.5.4.2].
The room sensor influence can be set in the Engineer level.
6.1.4 Weather compensated/Room control
The flow temperature of the heating circuit is controlled depending on the external
temperature and the room temperature.
An external sensor and room device or room sensor are required for weather compensated control and room temperature dependent control.
Mount the external sensor to the north side or the north-west side of the build-
ing, half way up (min 2.5 m).
Avoid direct solar radiation and heat up by external heat sources at the external
sensor and the room sensor.
The current flow temperature setpoint is calculated from:
This innovative Weishaupt technology for
medium and large burners provides minimum
emission values at capacities up to 17 MW.
The burners with the patented mixing head are
available for oil, gas and dual fuel operation.
The complete program:
Reliable technology and prompt, professional service
W Burnersup to 570 kW
The compact burners, proven millions of times
over, are economical and reliable. Available as
gas, oil and dual fuel burners for domestic and
commercial applications.
The purflam
®
burner version with special
mixing head gives almost soot-free combustion
of oil with greatly reduced NOx emissions.
monarch®WM Burners
and Industrial Burners up to 11,700 kW
These legendary industrial burners are durable
and versatile.
Numerous variations of oil, gas and dual fuel
burners meet a wide range of applications and
capacity requirements.
MCR Technology / Building Automation
from Neuberger
From control panels to complete building
management systems - at Weishaupt you can
find the entire spectrum of modern control
technology. Future orientated, economical and
flexible.
Service
Weishaupt customers can be assured that
specialist knowledge and tools are available
whenever they are needed. Our service
engineers are fully qualified and have
extensive product knowledge, be it for burners,
heat pumps, condensing boilers or solar
collectors.
Max Weishaupt GmbH · 88475 Schwendi
Weishaupt close by? Addresses, telephone numbers etc. can be found
at www.weishaupt.de
We reserve the right to make changes. All rights reserved.
Water heaters / energy storage tanks
This attractive program for domestic water
heating includes classic water heaters,
solar storage tanks, heat pump storage tanks
and energy storage tanks.
Solar systems
The stylish flat-plate collectors are the ideal
complement for any Weishaupt heating
system. They are suitable for solar water
heating and for combined heating support.
With versions for on-roof, in-roof and flat roof
installations, solar energy can be utilised on
almost any roof.
Wall-hung condensing boilers
for gas up to 240 kW
The wall-hung condensing boilers WTC-GW
have been developed to meet the highest
demands in ease of operation and efficiency.
Modulating operation means these units
operate quietly and economically.
Floor standing condensing boiler
for oil and gas up to 1,200 kW
The floor-standing boilers WTC-GB and
WTC-OB are efficient, low in emissions
and versatile. Higher capacities are achieved
by cascading up to four gas-fired condensing
boilers.
Heat pumps up to 180 kW
The heat pump range offers solutions for the
utilisation of heat from the air, the soil or
ground water.
Some systems are also suitable for cooling
buildings.
Geothermal probe drilling
With its daughter company, BauGrund Süd,
Weishaupt also offers geothermal probe and
well drilling. With the experience of more than
10,000 systems and more than 2 million meters
of drilling, BauGrund Süd offers a
comprehensive service program.
WK Burners up to 32,000 kW
These industrial burners of modular
construction are adaptable, robust and