This manual forms part of the equipment and must be kept on site.
Carefully read the manual prior to working on the unit.
It is supplemented by the installation and operating instructions for the condensing
unit.
1.1 Target group
The manual is intended for the operator and qualified personnel. They should be
observed by all personnel working with the unit.
Work on the unit must only be carried out by personnel who have the relevant training and instruction.
In accordance with EN 60335-1 the following requirements apply
This appliance can be used by children 8 years and above as well as by persons
with limited physical, sensory or mental capacities or lack of experience and knowledge, provided they are supervised or have been instructed regarding the safe use
of the appliance and understand the resulting danger. Children must not play with
the appliance. Cleaning and operator maintenance must not be carried out by children without supervision.
1.2 Symbols
DANGER
WARNING
CAUTION
…Range of values
Immediate danger with high risk.
Non observance can lead to serious injury or death.
Danger with medium risk.
Non observance can lead to environmental damage,
serious injury or death.
Danger with low risk.
Non observance can cause damage to the equipment and injury to personnel.
Important information
Requires direct action
Result after an action
Itemisation
83310002 1/2017-11 La
3-20
Page 4
1 User instructions
Installation and operating instruction
Room device WEM-RG1
1.3 Guarantee and Liability
Guarantee and liability claims for personal and equipment damage are excluded, if
they can be attributed to one or more of the following causes:
non approved application,
non-observance of the manual,
operation with faulty safety equipment,
continual operation despite a fault,
improper installation, commissioning, operation and service,
repairs, which have been carried out incorrectly,
the use of non original Weishaupt parts,
force majeure,
the installation of additional components, which have not been tested with the
unit.
83310002 1/2017-11 La
4-20
Page 5
Installation and operating instruction
Room device WEM-RG1
2 Safety
2 Safety
2.1 Designated application
The room device in conjunction with the Weishaupt Energy ManagementWEM is
suitable for the operation of a heating circuit.
The unit should only be used in enclosed rooms.
The installation location must comply with local regulations and must be frost-proof.
Improper use could:
endanger the health and safety of the user or third parties,
cause damage to the unit or other material assets.
2.2 Safety measures
Safety relevant fault conditions must be eliminated immediately.
2.3 Disposal
Dispose of all materials and components in a safe and environmentally friendly way
at an authorised location. Observe local regulations.
83310002 1/2017-11 La
5-20
Page 6
3 Product description
Installation and operating instruction
Room device WEM-RG1
3 Product description
3.1 Type key
WEM-RG1 …
WEMType: Weishaupt Energy Management
RG1Type: Room device basic version
…Version
83310002 1/2017-11 La
6-20
Page 7
Installation and operating instruction
80 mm
80 mm
Room device WEM-RG1
3 Product description
3.2 Technical data
3.2.1 Electrical data
Voltage supplyDC 15 … 30 V
Consumptionmax 0.7 W
Type of protectionIP 20
3.2.2 Ambient conditions
Temperature in operation0... +50°C
Temperature during transport / storage0... +50°C
relative humiditymax 85%, no dew point
3.2.3 Dimensions
83310002 1/2017-11 La
7-20
Page 8
4 Installation
WEM-FA-G
H L – +
H L – +
2
1
1
2
DANGER
Installation and operating instruction
Room device WEM-RG1
4 Installation
Risk of electric shock
Working on the device when voltage is applied can lead to electric shock.
Isolate the device from the power supply prior to starting any work.
Safeguard against accidental restart.
The electrical connection must only be carried out by qualified electricians. Observe local regulations.
If only 2 wires are available on site, the connection can be made using the
adapter set WEM-CAN 2 wire (RF / RG1) (accessory).
Secure wall bracket1 to the wall using the screws supplied.
Feed the wires2 through and connect the plug to the wiring diagram.
Insert the lugs1 of the room device into the recesses2.
Click room device into place downwards.
83310002 1/2017-11 La
8-20
Page 9
Installation and operating instruction
Room device WEM-RG1
Pull off protective foil.
4 Installation
83310002 1/2017-11 La
9-20
Page 10
5 Operation
2
3
5
1
4
Installation and operating instruction
Room device WEM-RG1
approx. 3seconds: back to standard display / abort
83310002 1/2017-11 La
10-20
Page 11
Installation and operating instruction
1
2345
6
7
9
8
Room device WEM-RG1
5.2 Display
1 Active mode (e.g. manual operation)
2 Summer setting activated (no heating operation)
3 Setback activated (reduced temperature level)
4 Normal operation activated (normal temperature level)
5 Comfort mode activated (increased temperature level)
6 Fault
7 Current room temperature (standard display); parameters and values
8 Setting mode activated
9 Service note
(1
(2
5 Operation
Faults
(1
If there is a fault in the system, a warning symbol appears in the display.
If an interlocking fault occurs, the warning symbol flashes, the system goes to lockout.
Notify Weishaupt Customer Service or your heating contractor.
Service note
(2
If the service interval of the condensing boiler has been exceeded, an spanner
wrench appears in the display.
Notify Weishaupt Customer Service or your heating contractor.
83310002 1/2017-11 La
11-20
Page 12
5 Operation
Installation and operating instruction
Room device WEM-RG1
5.3 ManualOperation
Permanent temperature level according to the operating mode set, independent of
the time program.
The following operating modes are possible:
Summer operation
Setback operation
Normal operation
Comfort mode
Press Manual operation .
Symbols for the operating modes are displayed flashing.
Select the desired operating mode using the knob.
Room setpoint temperature of the operating mode is displayed (except in summer operation).
Confirm operating mode using the dial knob.
The operating mode selected is active after approx. 3 seconds.
Example: Activate permanent setback operation.
5.4 Absence
The heating mode can be temporarily interrupted (maximum 23 hours). During the
time set, setback operation is activated.
Press Absence .
The hour display is displayed flashing.
Set and confirm hours required using the dial knob.
After approx. 3 seconds, setback operation is active for the time set.
Example: Activate absence (setback operation) for 8 hours.
Once the time set has elapsed, the operating mode previously set is active again.
Display the time remaining
Press Absence .
The time remaining is displayed flashing.
The standard display re-appears after approx. 30seconds.
83310002 1/2017-11 La
12-20
Page 13
Installation and operating instruction
Room device WEM-RG1
5 Operation
5.5 Party mode
The heating mode can be temporarily increased (maximum 23 hours). During the
time set, comfort mode is activated.
Press Party mode .
The hour display is displayed flashing.
Set and confirm hours required using the dial knob.
After approx. 3 seconds, comfort mode is active for the time set.
Example: Activate party mode (comfort mode) for 4 hours.
Once the time set has elapsed, the operating mode previously set is active again.
Display the time remaining
Press Party mode .
The time remaining is displayed flashing.
The standard display re-appears after approx. 30seconds.
5.6 Automatic operation
Temperature level according to predetermined time program.
The time programs can be interrogated and set using the display and operating unit
of the condensing boiler.
Press Automatic operation .
Automatic operation is activate after approx. 3 seconds.
83310002 1/2017-11 La
13-20
Page 14
5 Operation
Installation and operating instruction
Room device WEM-RG1
5.7 Set room setpoint temperature
Room setpoint temperature can be changed in each operating mode (except in
summer operation).
Press dial knob.
Display changes to the the setting of the room setpoint temperature.
The room setpoint temperature set is displayed flashing.
Set and confirm the required room temperature using the dial knob.
Room setpoint temperature has been changed.
Example: Increase room setpoint temperature in normal operation from 21.0 °C to
22.5 °C.
Following a change, the room setpoint temperature at the respective temperature
level is permanently changed.
83310002 1/2017-11 La
14-20
Page 15
Installation and operating instruction
Room device WEM-RG1
5 Operation
5.8 Service level
5.8.1 Check assignment
The heating circuit to which the room device is assigned can be displayed with
parameter 0F .
Press Manual operation and Automatic operation simultaneously for approx.2seconds.
The service level is activated.
Press dial knob.
The address of the heating circuit accessed is displayed.
The assignment can be changed using the display and operating unit of the condensing boiler.
The standard display re-appears after approx. 30seconds.
5.8.2 Adjusting the room temperature
If no optimal placement of the room device is possible or a measurement error is to
be compensated, the measured room temperature can be adjusted.
Setting range: -5.0 ... 5.0 K
Factory setting: 0.0
Press Manual operation and Automatic operation simultaneously for approx.2seconds.
The service level is activated.
Turn dial knob until parameter 1F is displayed.
Press dial knob.
Current room senor adjustment is displayed flashing.
Set and confirm adjustment required using the dial knob.
The value has been saved.
83310002 1/2017-11 La
The standard display re-appears after approx. 30seconds.
15-20
Page 16
5 Operation
Installation and operating instruction
Room device WEM-RG1
5.8.3 Set brightness in setting mode
Adjust the brightness of the display in setting mode.
Setting range: 0 ... 30
Factory setting: 30
Press Manual operation and Automatic operation simultaneously for approx.2seconds.
The service level is activated.
Turn dial knob until parameter 2F is displayed.
Press dial knob.
Current value of brightness is displayed flashing.
Set and confirm value required using the dial knob.
The value has been saved.
The standard display re-appears after approx. 30seconds.
5.8.4 Set brightness in standby mode
Adjust the brightness of the display in standby mode.
Setting range: 0 ... 30
Factory setting: 0
Press Manual operation and Automatic operation simultaneously for approx.2seconds.
The service level is activated.
Turn dial knob until parameter 3F is displayed.
Press dial knob.
Current value of brightness is displayed flashing.
Set and confirm value required using the dial knob.
The value has been saved.
Setting range: 0 ... 30
Factory setting: 0
83310002 1/2017-11 La
The standard display re-appears after approx. 30seconds.
16-20
Page 17
Installation and operating instruction
Room device WEM-RG1
Installation and operating instruction
Room device WEM-RG1
7 Notes
83310002 1/2017-11 La
18-20
Page 19
83310002 1/2017-11 La
Page 20
multiflam®Burnersup to 23,000 kW
This innovative Weishaupt technology for
medium and large burners provides minimum
emission values at capacities up to 17 MW.
The burners with the patented mixing head are
available for oil, gas and dual fuel operation.
The complete program:
Reliable technology and prompt, professional service
W Burnersup to 570 kW
The compact burners, proven millions of times
over, are economical and reliable. Available as
gas, oil and dual fuel burners for domestic and
commercial applications.
The purflam
®
burner version with special
mixing head gives almost soot-free combustion
of oil with greatly reduced NOx emissions.
monarch®WM Burners
and Industrial Burners up to 11,700 kW
These legendary industrial burners are durable
and versatile.
Numerous variations of oil, gas and dual fuel
burners meet a wide range of applications and
capacity requirements.
MCR Technology / Building Automation
from Neuberger
From control panels to complete building
management systems - at Weishaupt you can
find the entire spectrum of modern control
technology. Future orientated, economical and
flexible.
Service
Weishaupt customers can be assured that
specialist knowledge and tools are available
whenever they are needed. Our service
engineers are fully qualified and have
extensive product knowledge, be it for burners,
heat pumps, condensing boilers or solar
collectors.
Max Weishaupt GmbH · 88475 Schwendi
Weishaupt close by? Addresses, telephone numbers etc. can be found
at www.weishaupt.de
We reserve the right to make changes. All rights reserved.
Water heaters / energy storage tanks
This attractive program for domestic water
heating includes classic water heaters,
solar storage tanks, heat pump storage tanks
and energy storage tanks.
Solar systems
The stylish flat-plate collectors are the ideal
complement for any Weishaupt heating
system. They are suitable for solar water
heating and for combined heating support.
With versions for on-roof, in-roof and flat roof
installations, solar energy can be utilised on
almost any roof.
Wall-hung condensing boilers
for gas up to 240 kW
The wall-hung condensing boilers WTC-GW
have been developed to meet the highest
demands in ease of operation and efficiency.
Modulating operation means these units
operate quietly and economically.
Floor standing condensing boiler
for oil and gas up to 1,200 kW
The floor-standing boilers WTC-GB and
WTC-OB are efficient, low in emissions
and versatile. Higher capacities are achieved
by cascading up to four gas-fired condensing
boilers.
Heat pumps up to 180 kW
The heat pump range offers solutions for the
utilisation of heat from the air, the soil or
ground water.
Some systems are also suitable for cooling
buildings.
Geothermal probe drilling
With its daughter company, BauGrund Süd,
Weishaupt also offers geothermal probe and
well drilling. With the experience of more than
10,000 systems and more than 2 million meters
of drilling, BauGrund Süd offers a
comprehensive service program.
WK Burners up to 32,000 kW
These industrial burners of modular
construction are adaptable, robust and
powerful.
Even on the toughest industrial applications
these oil, gas and dual fuel burners operate
reliably.