Weidmuller DC-CCC-HF User Manual

8 Zubehör
Querverbinder ZQV 2,5N/2 schwarz 1718080000 Querverbinder ZQV 2,5N/2 rot 1717900000 Querverbinder ZQV 2,5N/2 blau 1717990000 Querverbinder ZQV 2,5N/2 gelb 1693800000
WAVESERIES Signal Conditioners DC/DC CCC HF with 3-Way Separation
Buchsenleiste 3 polig für Schraubanschluß BLZ 5.08/3 SN OR
- orange 1526560000
- schwarz 1526510000 Buchsenleiste 3 polig für Zugfederanschluß BLZF 5,08/3
- orange 1707470000
- schwarz 1707700000
Verbindermarkierer WS 10/5 Multicard für Plotterbeschriftung 1635010000 WS 10/5 Neutral 1060860000
Aus Gründen des Umweltschutzes empfehlen wir, überzählige oder nicht benötigte Beipackzettel dem Händler zur Wiederver­wertung zu überlassen. Auf chlorfreiem Papier gedruckt.
8 9
Type Cat. No.
Screw-type connection WAS5 CCC HF 0 ... 20 mA/0 ... 20 mA 8447160000 WAS5 CCC HF 0 ... 20 mA/4 ... 20 mA 8447190000 WAS5 CVC HF 0 ... 20 mA/0 ... 10 V 8447220000 WAS5 CCC HF 4 ... 20 V/0 ... 20 mA 8447250000 WAS5 CVC HF 4 ... 20 mA/0 ... 10 V 8447280000 WAS5 VCC HF 0 ... 10 V/0 ... 20 mA 8447310000 WAS5 VCC HF 0 ... 10 V/4 ... 20 mA 8447340000 WAS5 VVC HF 0 ... 10 V/0 ... 10 V 8447370000 WAS5 VVC HF - 10 ... + 10 V/- 10 ...+ 10 V 8561610000
Tension clamp connection WAZ5 CCC HF 0 ... 20 mA/0 ... 20 mA 8447170000 WAZ5 CCC HF 0 ... 20 mA/4 ... 20 mA 8447200000 WAZ5 CVC HF 0 ... 20 mA/0 ... 10 V 8447230000 WAZ5 CCC HF 4 ... 20 mA/0 ... 20 mA 8447260000 WAZ5 CVC HF 4 ... 20 mA/0 ... 10 V 8447290000 WAZ5 VCC HF 0 ... 10 V/0 ... 20 mA 8447320000 WAZ5 VCC HF 0 ... 10 V/4 ... 20 mA 8447350000 WAZ5 VVC HF 0 ... 10 V/0 ... 10 V 8447380000 WAZ5 VVC HF - 10 ... + 10 V/- 10 ...+ 10 V 8587000000
Read these instructions before using the product and retain for future information.
1 General instructions
The WAVESERIES signal conditioner DC/DC CCC HF with 3-way separation should only be installed by qualified staff and be pow­ered up following professional installation.
2 Application
The WAVESERIES signal conditioner DC/DC CCC HF with 3-way separation converts feedback-free all standardised in- and output signals. These signal conditioners are supplied with voltage from the controller and feed the input side through a DC/DC-condition­er. Thereby is not only the input/output circuitry galvanically sepa­rated but also the supply side.
3 Mounting and dismounting
Warning!! Mounting and dismounting may only be carried out
when the power supply has be disconnected. Failure to observe will lead to considerable damage!
10 11
3.1 Mounting onto TS 35 DIN rails
(s. Fig. 1)
3.2 Pluggable electronic components for range alteration (depending on model)
(s. Fig. 2)
1. Remove connector, (depending on model either screw-type or tension clamp).
2. Press locking clips on both sides of the enclosure.
3. Pull out the circuit board.
Warning!! The circuit board can only be inserted in one position.
The connectors have been coded by the manufactur­er, ensuring that they cannot be reversed.
3.3 Pluggable cross-connections for voltage supply
(s. Fig. 3)
A maximum feed through of 2 A is possible. If a signal conditioner is accidently rotated through 180°, the cross-connection cannot be inserted.