8 Zubehör
Querverbinder ZQV 2,5N/2 schwarz 1718080000
Querverbinder ZQV 2,5N/2 rot 1717900000
Querverbinder ZQV 2,5N/2 blau 1717990000
Querverbinder ZQV 2,5N/2 gelb 1693800000
WAVESERIES Signal Conditioners
DC/DC CCC HF with
3-Way Separation
Buchsenleiste 3 polig für Schraubanschluß BLZ 5.08/3 SN OR
- orange 1526560000
- schwarz 1526510000
Buchsenleiste 3 polig für Zugfederanschluß BLZF 5,08/3
- orange 1707470000
- schwarz 1707700000
Verbindermarkierer
WS 10/5 Multicard für Plotterbeschriftung 1635010000
WS 10/5 Neutral 1060860000
Aus Gründen des Umweltschutzes empfehlen wir, überzählige
oder nicht benötigte Beipackzettel dem Händler zur Wiederverwertung zu überlassen.
Auf chlorfreiem Papier gedruckt.
8 9
Type Cat. No.
Screw-type connection
WAS5 CCC HF 0 ... 20 mA/0 ... 20 mA 8447160000
WAS5 CCC HF 0 ... 20 mA/4 ... 20 mA 8447190000
WAS5 CVC HF 0 ... 20 mA/0 ... 10 V 8447220000
WAS5 CCC HF 4 ... 20 V/0 ... 20 mA 8447250000
WAS5 CVC HF 4 ... 20 mA/0 ... 10 V 8447280000
WAS5 VCC HF 0 ... 10 V/0 ... 20 mA 8447310000
WAS5 VCC HF 0 ... 10 V/4 ... 20 mA 8447340000
WAS5 VVC HF 0 ... 10 V/0 ... 10 V 8447370000
WAS5 VVC HF - 10 ... + 10 V/- 10 ...+ 10 V 8561610000
Tension clamp connection
WAZ5 CCC HF 0 ... 20 mA/0 ... 20 mA 8447170000
WAZ5 CCC HF 0 ... 20 mA/4 ... 20 mA 8447200000
WAZ5 CVC HF 0 ... 20 mA/0 ... 10 V 8447230000
WAZ5 CCC HF 4 ... 20 mA/0 ... 20 mA 8447260000
WAZ5 CVC HF 4 ... 20 mA/0 ... 10 V 8447290000
WAZ5 VCC HF 0 ... 10 V/0 ... 20 mA 8447320000
WAZ5 VCC HF 0 ... 10 V/4 ... 20 mA 8447350000
WAZ5 VVC HF 0 ... 10 V/0 ... 10 V 8447380000
WAZ5 VVC HF - 10 ... + 10 V/- 10 ...+ 10 V 8587000000
Read these instructions before using the product
and retain for future information.
1 General instructions
The WAVESERIES signal conditioner DC/DC CCC HF with 3-way
separation should only be installed by qualified staff and be powered up following professional installation.
2 Application
The WAVESERIES signal conditioner DC/DC CCC HF with 3-way
separation converts feedback-free all standardised in- and output
signals. These signal conditioners are supplied with voltage from
the controller and feed the input side through a DC/DC-conditioner. Thereby is not only the input/output circuitry galvanically separated but also the supply side.
3 Mounting and dismounting
Warning!! Mounting and dismounting may only be carried out
when the power supply has be disconnected. Failure
to observe will lead to considerable damage!
10 11
3.1 Mounting onto TS 35 DIN rails
(s. Fig. 1)
3.2 Pluggable electronic components for range alteration
(depending on model)
(s. Fig. 2)
1. Remove connector, (depending on model either screw-type
or tension clamp).
2. Press locking clips on both sides of the enclosure.
3. Pull out the circuit board.
Warning!! The circuit board can only be inserted in one position.
The connectors have been coded by the manufacturer, ensuring that they cannot be reversed.
3.3 Pluggable cross-connections for voltage supply
(s. Fig. 3)
A maximum feed through of 2 A is possible.
If a signal conditioner is accidently rotated through 180°, the
cross-connection cannot be inserted.