WEG Electric HVW701 Data Sheet

Information
General
CFW100 CFW300 CFW500 CF W11 M PUMP
CFW70 0 CF W11
GENIUS
Variable Frequency Drives
HVW701 HVAC-R By-Pass
The WEG HVW701 HVAC-R By-Pass system is comprised of the CFW701 Variable Frequency Drive with integral By-Pass. It is designed for heating, ventilation, air conditioning and refrigeration systems where continued operation is critical and space is at a premium. The HVW701 is designed to provide reliable and energy-efficient control for applications in office buildings, hospitals, airports, hotels, shopping centers or other similar facilities.
SINGLE
PHASE
EDP700
CFW70 0
CFW08
CFW701 HVW 701 SSW05 SSW07CFW501 SSW06 EDP 11
HVW701 HVAC-R By-Pass
Available Configurations
Frame A, B and C
NEMA 1 with 3-Contactor By-Pass NEMA 1 with 2-Contactor By-Pass NEMA 1 with Circuit Breaker Only NEMA 1 with 3-Contactor By-Pass and 65kAIC CB NEMA 1 with 2-Contactor By-Pass and 65kAIC CB NEMA 1 with Circuit Breaker Only and 65kAIC CB
2-Contactor By-Pass Example
Frame D and E
GPH2 TPH2
NEMA 12 or 3R with 3-Contactor By-Pass NEMA 12 or 3R with 2-Contactor By-Pass NEMA 12 or 3R with Circuit Breaker Only
86 |
86 |
Data is subject to change without notice.
Data is subject to change without notice.
Variable Frequency Drives
HVW701-Table
HVW701 Catalog Number Sequence
B D N01 2 0 0 0 0 0
C = 208 Vac
D = 230 Vac N01 = NEMA 1 (Standard)
G = 460 Vac N12 = NEMA 12 *
N3R = NEMA 3R *
* N12 and N3R only available in Frame D and E
3 = 3-Contactor Bypass Includes: Drive/Test/Bypass Sel. Switch 0 = Disconnect Only No Selector Switches, No Pilot Lights
2 = 2-Contactor Bypass Includes: Drive/Bypass Sel. Switch;
HOA Sel. Switch; Fault, Drive, Bypass Pilot Lights
105 = 105 Amps
142 = 142 Amps
211 = 211 Amps
180 = 180 Amps
007 = 7 Amps
045 = 45 Amps
010 = 10 Amps
024 = 24 Amps
HVW701
024
A, B, C, D, E
HVW701
HAVC Drive Panel with By-Pass - NEMA 1 Enclosure
Frame LonWorks® Gateway
Rated Current
Bypass Options and Operator Devices
Supply Voltage
Future
0 = No LonWorks® 1 = LonWorks Gateway
CB kAIC Rating
Reserved
HOA Sel. Switch; Fault, Drive, Bypass Pilot Lights
Enclosure
HVW701
General
Information
CF W11 MCFW701 CFW501 CFW70 0 CFW500 CFW300 CFW100CF W11
PUMP
GENIUS
Table intended for reference only and not to create part numbers.
CFW70 0
SSW07 SSW05 HV W701 CFW08
SSW06
PHASE
SINGLE
Data is subject to change without notice.
Data is subject to change without notice.
WEG Automation - Products and Solutions | 87
WEG Automation - Products and Solutions | 87
EDP700
TPH2 GPH2 ED P11
Information
GENIUS
SINGLE
PHASE
EDP700
General
Variable Frequency Drives
HVW701
HVAC Drive Panel - NEMA 1 Enclosure - 2-Contactor Bypass
CFW100 CFW300 CFW500 CF W11 M PUMP
Motor
Voltage
Motor
HP
Input Power Supply: Three-Phase 220-240 Vac with Dynamic Braking Transistor
CFW70 0 CF W11
7 1/2 24 HVW701B024DN01200000 Yes B HV1 34.1 x 7.8 x 15 87 V3
230 Vac
Input Power Supply: Three-Phase 220-240 Vac without Dynamic Braking Transistor
CFW70 0
Input Power Supply: Three-Phase 460-480 Vac with Dynamic Braking Transistor
CFW08
7 1/2 10 HVW701A010GN01200000 Yes A HV1 36 x 7.8 x 15 75 V3
CFW701 HVW 701 SSW05 SSW07CFW501 SSW06 EDP 11
460 Vac
50/60 70.5 HVW701D070GN01200000 Ye s D ED4 36 x 30 x 14 230 V3
Input Power Supply: Three-Phase 460-480 Vac without Dynamic Braking Transistor
100/125 142 HVW701E142GN01200000 No E
150 180 HVW701E180GN01200000 No E
175 211 HVW701E211GN01200000 No E
Notes:
1) CT = Consta nt Torque, 150% overl oad / 60 s ec.; V T = Variable Torque (Q uadr atic Lo ad), 110% overload / 60 se c.
2) “HP” r ating based on “average FLA va lues”. Use as a gu ide onl y.
3) Motor FL A may var y with spee d and ma nufac ture r. ALWAYS compare motor FLA to N ominal AMPS of d rive.
4) ED3 and E D4 enclosur es are non-ve ntilated an d wall- moun ted
5) Max imum 45°C ambient tem pera ture wi thout derat ing
6) Dime nsions and we ights a re for e stimating purpos es onl y. Only us e “AS BUILT” drawi ngs fo r const ructi on.
GPH2 TPH2
For othe r technical d ata ple ase refer to WEG product man ual.
1
ND / VT
2
Drive
Amps
Catalog
3
Number
Braking
Transistor
Drive
Frame
Size
Enclosure
2 7.0 HVW701A007DN01200000 Yes A HV1 34.1 x 7.8 x 15 75 V3
3 10 HVW701A010DN01200000 Yes A HV1 34.1 x 7.8 x 15 75 V3
5 13 HVW701A013DN01200000 Yes A HV1 34.1 x 7.8 x 15 75 V3
5 16 HVW701A016DN01200000 Yes A HV1 34.1 x 7.8 x 15 75 V3
10 28 HVW701B028DN01200000 Yes B HV1 34.1 x 7.8 x 15 87 V3
10 33.5 HVW701B033DN01200000 Ye s B HV1 34.1 x 7.8 x 15 87 V3
15 45 HVW701C045DN01200000 Yes C HV2 43.9 x 9 x 16 133 V3
20 54 HVW701C054DN01200000 Yes C HV2 43.9 x 9 x 16 133 V3
25 70 HVW701C070DN01200000 Ye
s C HV2 43.9 x 9 x 16 133 V3
30 86 HVW701D086DN01200000 Ye s D ED3 36 x 30 x 14 230 V3
40 105 HVW701D105DN01200000 Ye s D ED3 36 x 30 x 14 240 V3
50 142 HVW701E142DN01200000 No E
60 180 HVW701E180DN01200000 No E
75 211 HVW701E211DN01200000 No E
5
5
5
2 3.6 HVW701A003GN01200000 Yes A HV1 36 x 7.8 x 15 75 V3
3 5.0 HVW701A005GN01200000 Yes A HV1 36 x 7.8 x 15 75 V3
5 7.0 HVW701A007GN01200000 Yes A HV1 36 x 7.8 x 15 75 V3
10 13.5 HVW701A013GN01200000 Ye s A HV1 36 x 7.8 x 15 75 V3
10 17 HVW701B017GN01200000 Yes B HV1 36 x 7.8 x 15 87 V3
15 24 HVW701B024GN01200000 Yes B HV1 36 x 7.8 x 15 87 V3
20 31 HVW701B031GN01200000
Yes B HV1 36 x 7.8 x 15 87 V3
25 38 HVW701C038GN01200000 Yes C HV2 43.9 x 9 x 16 133 V3
30 45 HVW701C045GN01200000 Yes C HV2 43.9 x 9 x 16 133 V3
40 58.5 HVW701C058GN01200000 Ye s C HV2 43.9 x 9 x 16 133 V3
75 88 HVW701D088GN01200000 Ye s D ED4 36 x 30 x 14 240 V3
75 105 HVW701E105GN01200000 No E
5
5
5
5
Frame
Size
4
Dimensions
(in.)
HxWxD
Approx.
Weight
6
(lbs.)
6
Multiplier
ED4 48 x 30 x 17.5 300 V3
ED4 48 x 30 x 17.5 300 V3
ED4 48 x 30 x 17.5 300 V3
ED5 48 x 30 x 17.5 300 V3
ED5 48 x 30 x 17.5 300 V3
ED5 48 x 30 x 17.5 300 V3
ED5 48 x 30 x 17.5 300 V3
88 |
88 |
Data is subject to change without notice.
Data is subject to change without notice.
Loading...
+ 5 hidden pages