WEG 25012XT3G449T User Manual

Customer :
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 28-DEC-2012
TECHNICAL PROPOSAL
Product line :
Catalog Number : 25012XT3G449T List Price : $48,048
Performed by: Checked:
Three-Phase : Explosion Proof - NEMA Premium
DATA SHEET
Three-phase induction motor - Squirrel cage rotor
Customer : Product line :
Frame : 449T Output : 250 HP Frequency : 60 Hz Poles : 6 Full load speed : 1190 Slip : 0.83 % Voltage : 460 V Rated current : 299 A Locked rotor current : 2420 A Locked rotor current (Il/In) : 8.1 No-load current : 134 A Full load torque : 1088 lb.ft Locked rotor torque : 280 % Breakdown torque : 300 % Design : A Insulation class : F Temperature rise : 80 K Locked rotor time : 10 s (hot) Service factor : 1.15 Duty cycle : S1 Ambient temperature : -20°C - +40°C Altitude : 1000 Degree of Protection : IP54 Approximate weight : 3188 lb Moment of inertia : 144.52 sq.ft.lb Noise level : 70 dB(A)
Three-Phase : Explosion Proof - NEMA Premium
No.:
Date: 28-DEC-2012
D.E. N.D.E. Load Power factor Efficiency (%) Bearings 6322 C3 6319 C3 100% 0.81 95.8 Regreasing interval 9212 h 11094 h 75% 0.76 95.4 Grease amount 60 g 45 g 50% 0.64 95.0
Performed by Checked
PERFORMANCE CURVES RELATED TO RATED OUTPUT
Three-phase induction motor - Squirrel cage rotor
100
1.0 0.0
90
0.9
80
0.8
70
0.7
60
0.6
C
A
No.:
Date: 28-DEC-2012
C - Slip D - Current at 460V (A)
1.0
2.0
3.0
4.0
50
0.5
40
0.4
A - Efficiency (%)
B - Power factor
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Customer : Product line :
Frame : 449T Output : 250 HP Frequency : 60 Hz Full load speed : 1190 Voltage : 460 V Rated current : 299 A Insulation class : F
Three-Phase : Explosion Proof - NEMA Premium
B
D
Percent of rated output (%)
Locked rotor current (Il/In) : 8.1 Duty cycle : S1 Service factor : 1.15 Design : A Locked rotor torque : 280 % Breakdown torque : 300 %
5.0
400
300
200
100
0
Performed by Checked
5.0
CHARACTERISTIC CURVES RELATED TO SPEED
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 28-DEC-2012
10.0
B - Current related to rated current (I/In)
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
A - Torque related to rated torque (C/Cn)
Customer : Product line :
0 10 20 30 40 50 60 70 80 90 100
B
Speed related to rated speed (%)
Three-Phase : Explosion Proof - NEMA Premium
9.0
8.0
7.0
A
6.0
5.0
4.0
3.0
2.0
1.0
0.0
Frame : 449T Output : 250 HP Frequency : 60 Hz Full load speed : 1190 Voltage : 460 V Rated current : 299 A Insulation class : F
Performed by Checked
Locked rotor current (Il/In) : 8.1 Duty cycle : S1 Service factor : 1.15 Design : A Locked rotor torque : 280 % Breakdown torque : 300 %
1 2 3 4 5 6 7 8
A
B
C
D
E
2E
18.000 J
3.937 S
0.875 D
F
11.000 C
54.996
Flange
FD-508
BB
0.203
A
21.929 K
7.104 N-W
8.500
G
1.630
AA
2XNPT 3"
AJ
20.000
2F
25.000 P
24.016 U
3.375 O
23.622 d1
DUNC 3/4"-10
AK
18.000
B
32.126 ES
7.087 R
2.880
HD
27.165 d2
DUNC 3/4"-10
BD
21.656
BA
7.500 depth
0.875 AB
20.984 H
0.807 T
3.543
BF
18.000
Performed by:
Checked:
Customer:
Three-Phase : Explosion Proof - NEMA Premium
28-DEC-2012Three-phase induction motor
Frame 449T - IP54
Loading...