Customer :
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 27-DEC-2012
TECHNICAL PROPOSAL
Product line :
Catalog Number : 06036XT3E364TS
List Price : $9,988
Notes:
Performed by: Checked:
Three-Phase : Explosion Proof - NEMA Premium

DATA SHEET
Three-phase induction motor - Squirrel cage rotor
Customer :
Product line :
Frame : 364/5TS
Output : 60 HP
Frequency : 60 Hz
Poles : 2
Full load speed : 3560
Slip : 1.11 %
Voltage : 208-230/460 V
Rated current : 151-137/68.3 A
Locked rotor current : 874/437 A
Locked rotor current (Il/In) : 6.4
No-load current : 32.6/16.3 A
Full load torque : 87.3 lb.ft
Locked rotor torque : 200 %
Breakdown torque : 250 %
Design : B
Insulation class : F
Temperature rise : 80 K
Locked rotor time : 60 s (hot)
Service factor : 1.15
Duty cycle : S1
Ambient temperature : -20°C - +40°C
Altitude : 1000
Degree of Protection : IP54
Approximate weight : 1017 lb
Moment of inertia : 9.9623 sq.ft.lb
Noise level : 85 dB(A)
Three-Phase : Explosion Proof - NEMA Premium
No.:
Date: 27-DEC-2012
D.E. N.D.E. Load Power factor Efficiency (%)
Bearings 6314 C3 6314 C3 100% 0.88 94.1
Regreasing interval 3604 h 3604 h 75% 0.86 93.6
Grease amount 27 g 27 g 50% 0.79 92.4
Notes:
Performed by Checked

PERFORMANCE CURVES RELATED TO RATED OUTPUT
Three-phase induction motor - Squirrel cage rotor
100
1.0 0.0
C
No.:
Date: 27-DEC-2012
C - Slip D - Current at 230V (A)
90
0.9
80
0.8
70
0.7
60
0.6
50
0.5
40
0.4
A - Efficiency (%)
B - Power factor
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Customer :
Product line :
A
B
D
Percent of rated output (%)
Three-Phase : Explosion Proof - NEMA Premium
1.0
2.0
3.0
4.0
5.0
160
120
80
40
0
Frame : 364/5TS
Output : 60 HP
Frequency : 60 Hz
Full load speed : 3560
Voltage : 208-230/460 V
Rated current : 151-137/68.3 A
Insulation class : F
Notes:
Performed by Checked
Locked rotor current (Il/In) : 6.4
Duty cycle : S1
Service factor : 1.15
Design : B
Locked rotor torque : 200 %
Breakdown torque : 250 %

5.0
CHARACTERISTIC CURVES RELATED TO SPEED
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 27-DEC-2012
10.0
B - Current related to rated current (I/In)
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
A - Torque related to rated torque (C/Cn)
Customer :
Product line :
0 10 20 30 40 50 60 70 80 90 100
B
Speed related to rated speed (%)
Three-Phase : Explosion Proof - NEMA Premium
9.0
8.0
7.0
6.0
A
5.0
4.0
3.0
2.0
1.0
0.0
Frame : 364/5TS
Output : 60 HP
Frequency : 60 Hz
Full load speed : 3560
Voltage : 208-230/460 V
Rated current : 151-137/68.3 A
Insulation class : F
Notes:
Performed by Checked
Locked rotor current (Il/In) : 6.4
Duty cycle : S1
Service factor : 1.15
Design : B
Locked rotor torque : 200 %
Breakdown torque : 250 %

1 2 3 4 5 6 7 8
A
B
C
D
Notes:
E
2E
14.000
J
3.150
S
0.500
D
F
9.000
C
31.575
Flange
FD-406
BB
0.203
A
17.165
K
4.134
N-W
3.748
G
1.480
AA
NPT 3"
AJ
16.000
2F
11.250/12.250
P
18.583
U
1.875
O
18.898
d1
DUNC 3/4"-10
AK
14.000
B
15.394
ES
1.968
R
1.591
HD
21.693
d2
DUNC 3/4"-10
BD
18.000
BA
5.875
depth
0.500
AB
16.654
H
0.657
T
2.795
BF
0.828
Performed by:
Checked:
Customer:
Three-Phase : Explosion Proof - NEMA Premium
27-DEC-2012Three-phase induction motor
Frame 364/5TS - IP54