WEG 04089EP3PCT326V-W22 User Manual

Page 1
Customer :
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 31-DEC-2012
TECHNICAL PROPOSAL
Product line :
Catalog Number : 04089EP3PCT326V List Price : $5,464
Performed by: Checked:
Cooling Tower Motors : High Efficiency - Two Speed
Page 2
DATA SHEET
Three-phase induction motor - Squirrel cage rotor
Customer : Product line :
Frame : 326T Output : 10 HP Frequency : 60 Hz Poles : 8 Full load speed : 885 Slip : 1.67 % Voltage : 200 V Rated current : 41.4 A Locked rotor current : 128 A Locked rotor current (Il/In) : 3.1 No-load current : 23.0 A Full load torque : 58.5 lb.ft Locked rotor torque : 160 % Breakdown torque : 170 % Design : A Insulation class : F Temperature rise : 80 K Locked rotor time : 50 s (hot) Service factor : 1.15 Duty cycle : S1 Ambient temperature : -20°C - +40°C Altitude : 1000 Degree of Protection : IP55 Approximate weight : 595 lb Moment of inertia : 9.1622 sq.ft.lb Noise level : 56 dB(A)
Cooling Tower Motors : High Efficiency - Two Speed
No.:
Date: 31-DEC-2012
D.E. N.D.E. Load Power factor Efficiency (%) Bearings 6312 2RS 6212 2RS 100% 0.60 87.0 Regreasing interval --- --- 75% 0.56 87.0 Grease amount --- --- 50% 0.45 85.0
Performed by Checked
Page 3
PERFORMANCE CURVES RELATED TO RATED OUTPUT
Three-phase induction motor - Squirrel cage rotor
100
1.0 0.0
90
0.9
80
0.8
70
0.7
60
0.6
50
0.5
40
0.4
C
A
B
D
No.:
Date: 31-DEC-2012
C - Slip D - Current at 200V (A)
1.0
2.0
3.0
4.0
5.0
40
30
20
10
A - Efficiency (%)
B - Power factor
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Customer : Product line :
Frame : 326T Output : 10 HP Frequency : 60 Hz Full load speed : 885 Voltage : 200 V Rated current : 41.4 A Insulation class : F
Cooling Tower Motors : High Efficiency - Two Speed
0
Percent of rated output (%)
Locked rotor current (Il/In) : 3.1 Duty cycle : S1 Service factor : 1.15 Design : A Locked rotor torque : 160 % Breakdown torque : 170 %
Performed by Checked
Page 4
5.0
CHARACTERISTIC CURVES RELATED TO SPEED
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 31-DEC-2012
10.0
B - Current related to rated current (I/In)
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
A - Torque related to rated torque (C/Cn)
Customer : Product line :
0 10 20 30 40 50 60 70 80 90 100
B
Speed related to rated speed (%)
Cooling Tower Motors : High Efficiency - Two Speed
9.0
8.0
7.0
6.0
5.0
4.0
A
3.0
2.0
1.0
0.0
Frame : 326T Output : 10 HP Frequency : 60 Hz Full load speed : 885 Voltage : 200 V Rated current : 41.4 A Insulation class : F
Performed by Checked
Locked rotor current (Il/In) : 3.1 Duty cycle : S1 Service factor : 1.15 Design : A Locked rotor torque : 160 % Breakdown torque : 170 %
Page 5
1 2 3 4 5 6 7 8
A
B
C
D
E
Performed by:
2E
12.500 B
14.567 K
F
3.346 N-W
5.250
d1
A 4
BF
0.828
2F
12.000 C
31.116 O
15.953 U
2.125
Flange
FD-406
BB
0.203
H
0.657 D
8.000 P
15.591 R
1.844 AJ
16.000
BA
5.250 G
1.307
ES
3.937
AB
11.496 AK
14.000
A
15.157 J
3.228 S
0.500
AA
NPT 2"
BD
18.000
Checked:
Customer:
Cooling Tower Motors : High Efficiency - Two Speed
31-DEC-2012Three-phase induction motor
Frame 326T - IP55
Loading...