Customer :
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 28-DEC-2012
TECHNICAL PROPOSAL
Product line :
Catalog Number : 00236ES3EJPR56J
List Price : $430
Notes:
Performed by: Checked:
Jet Pump - NEMA 56 : Three-Phase - Threaded - TEFC (IP55)

DATA SHEET
Three-phase induction motor - Squirrel cage rotor
Customer :
Product line :
Frame : D56
Output : 2 HP
Frequency : 60 Hz
Poles : 2
Full load speed : 3460
Slip : 3.89 %
Voltage : 208-230/460 V
Rated current : 5.75-5.40/2.70 A
Locked rotor current : 48.6/24.3 A
Locked rotor current (Il/In) : 9.0
No-load current : 2.60/1.30 A
Full load torque : 2.99 lb.ft
Locked rotor torque : 420 %
Breakdown torque : 400 %
Design : A
Insulation class : F
Temperature rise : 80 K
Locked rotor time : 10 s (hot)
Service factor : 1.15 (1.00 at 208V)
Duty cycle : S1
Ambient temperature : -20°C - +40°C
Altitude : 1000
Degree of Protection : IP55
Approximate weight : 36 lb
Moment of inertia : 0.06288 sq.ft.lb
Noise level : ---
Jet Pump - NEMA 56 : Three-Phase - Threaded - TEFC (IP55)
No.:
Date: 28-DEC-2012
D.E. N.D.E. Load Power factor Efficiency (%)
Bearings 6204 2RS 6202 2RS 100% 0.86 81.5
Regreasing interval --- --- 75% 0.79 80.0
Grease amount --- --- 50% 0.67 77.0
Notes:
Performed by Checked

PERFORMANCE CURVES RELATED TO RATED OUTPUT
Three-phase induction motor - Squirrel cage rotor
100
1.0 0.0
C
90
0.9
80
0.8
No.:
Date: 28-DEC-2012
C - Slip D - Current at 230V (A)
2.0
4.0
70
0.7
60
0.6
50
0.5
40
0.4
A - Efficiency (%)
B - Power factor
0 10 20 30 40 50 60 70 80 90 100 110 120 130
Customer :
Product line :
Frame : D56
Output : 2 HP
Frequency : 60 Hz
Full load speed : 3460
Voltage : 208-230/460 V
Rated current : 5.75-5.40/2.70 A
Insulation class : F
A
B
D
Percent of rated output (%)
Jet Pump - NEMA 56 : Three-Phase - Threaded - TEFC (IP55)
6.0
8.0
10.0
8
6
4
2
0
Locked rotor current (Il/In) : 9.0
Duty cycle : S1
Service factor : 1.15 (1.00 at 208V)
Design : A
Locked rotor torque : 420 %
Breakdown torque : 400 %
Notes:
Performed by Checked

5.0
CHARACTERISTIC CURVES RELATED TO SPEED
Three-phase induction motor - Squirrel cage rotor
No.:
Date: 28-DEC-2012
10.0
B - Current related to rated current (I/In)
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
A - Torque related to rated torque (C/Cn)
Customer :
Product line :
0 10 20 30 40 50 60 70 80 90 100
B
A
Speed related to rated speed (%)
Jet Pump - NEMA 56 : Three-Phase - Threaded - TEFC (IP55)
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
Frame : D56
Output : 2 HP
Frequency : 60 Hz
Full load speed : 3460
Voltage : 208-230/460 V
Rated current : 5.75-5.40/2.70 A
Insulation class : F
Notes:
Performed by Checked
Locked rotor current (Il/In) : 9.0
Duty cycle : S1
Service factor : 1.15 (1.00 at 208V)
Design : A
Locked rotor torque : 420 %
Breakdown torque : 400 %

1 2 3 4 5 6 7 8
A
B
C
D
Notes:
E
Performed by:
Checked:
Customer:
Jet Pump - NEMA 56 : Three-Phase - Threaded - TEFC (IP55)
F
P
7.323
AK
4.500
AH
AB
5.433
BD
6.535
AA
NPT 1/2"
BF
UNC 3/8"x16-2B
Flange
FC-149
BB
0.157
AJ
5.874
BC
---
28-DEC-2012Three-phase induction motor
Frame D56 - IP55