WE-EF FLC200 LED, FLC240 LED, FLC230 LED, FLC260 LED, FLC220 Installation And Maintenance Instructions

...
Thailand Tel +66 2 738 9610 Fax +66 2 175 2174 info.asiapacific@we-ef.com
Australia Tel +61 3 8587 0444 Fax +61 3 8587 0499 info.australia@we-ef.com
United States of America Tel +1 724 742 0030 Fax +1 724 742 0035 info.usa@we-ef.com
www.we-ef.com
WE-EF LEUCHTEN
Germany Tel +49 5194 909 0 Fax +49 5194 909 299
info.germany@we-ef.com
WE-EF LUMIERE
France Tel +33 4 74 99 14 44 Fax +33 4 74 99 14 40
info.france@we-ef.com
WE-EF HELVETICA
Switzerland Tel +41 22 752 49 94 Fax +41 22 752 49 74
info.switzerland@we-ef.com
WE-EF LIGHTING
United Kingdom Tel +44 844 880 5346 Fax +44 844 880 5347
info.uk@we-ef.com
INSTALLER
HOTLINE
+61 458 933 399
7am – 7pm AEST
WE-EF LEUCHTEN
Installation and
Maintenance Instructions for
Projectors
FLC200 LED Series
INSTALLER
HOTLINE
+61 458 933 399
7am – 7pm AEST
FLC200 LED_280618 / 006-1348-OZ
Technical specifications are subject to change. © WE-EF 2018
Safety Notice
The manufacturer is discharged from liability when damage is caused by improper use or installation.
If any luminaire and/or accessory is modified from that supplied by WE-EF, the persons responsible for the modification shall be considered as manufacturer.
Projectors
FLC240: . . . . . . . . . . . . . . . . . . . 24 LED 48W / 72W / 104W
FLC260: . . . . . . . . . . . . . . . . . . 36 LED 72W / 108 W / 155W
B
F
C
E
A
H
G
D
160
145
ø 260
70
ø 18
ø 14
44
165
190
ø 340
70
ø 18
ø 14
44
175
195
ø 385
60
44
ø 18
ø 14
FLC240
FLC260
FLC240: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,090 m²
FLC260: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,116 m²
FLC240: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 13,8 kg
FLC260: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 18.8 kg
ø 5,5 – 12 mm
0,14 – 2,5 mm
2
DMX-Power
M4 max. 2,0 Nm M5 max. 4,0 Nm M6 max. 6,0 Nm M8 max. 15,0 Nm M16 max. 100,0 Nm
FLC230
Lamps
FLC230:
. . . . . . . . . . . . . . . . . . . . 12 LED 24W / 36W / 52W
Protection: IP66, IK08 (PMMA), IK06 (Safety glass lens)
Class I, ta = 25°C
Windage area
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,054 m²
FLC230:
Weight:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 9,1 kg
FLC230:
Maintenance
Apart from cleaning the product’s exterior surfaces, no special maintenance work is required. Clean only with a
cloth and water
Do not use high-pressure cleaners.
Protect our environment: Discard used LEDs in compliance with the most recent environmental legislation.
Torque
Screw Torque
Tools required
– Screwdriver TX 25 – Screwdriver TX 40 – Screwdriver with blade 3x1 – Screwdriver TX70
Installation
The product must be installed and maintained by a suitably qualified professional in compliance with latest building/ construction and/or electrical regulations and relevant legislation.
Warning: Switch off and isolate mains electrical supply prior to installing and connecting the luminaire. Do not open the luminaire while mains supply is switched on.
Notice: If the luminaire is modified by anybody other than the original manufacturer, then the warranty will no longer be valid and shall become the full responsibility of the modifying person/organisation. Claims based on defects attributable to improper installation and/or application, and the consequences thereof, are excluded.
In case of component failure due to abnormal circumstances or at end of life, replacement must be carried out by a suit­ably qualified and trained professional.
ON-OFF7/7ADVANCED
BASIC
1-10V
DMX
DALI
Wiring Diagram
WE-EF Eco Step Dim® Advanced and
Shield
Da
Da
non dimmable luminaires
Class I Phase to L1, Neutral to N and Earthing to
WE-EF Eco Step Dim® Basic
Class I Phase to L1, Control Phase to L2
,
Neutral to N and Earthing to
Installation Procedure
1) Prior to electrical connection, proceed with mechanical
installation by firmly fixing stirrup A to optional mounting
accessory or directly to a suitable surface. Aim luminaire. Caution: Make sure not to damage any electric cable,
water pipe or other devices while drilling holes.
2) Switch off and isolate the mains electrical supply.
3) Remove gear box cover B by releasing screws C.
4) Check that rating shown on the luminaire label conforms
with the mains electrical supply.
5) Feed suitable mains supply cable D through cable gland
E. An additional gland is supplied to allow loop through
of supply cabling or alternative DMX cabling
arrangements
6) Connect to the correspondingly marked contacts of
terminal F, according to the wiring diagram. Tighten cable gland E firmly.
1-10V / DALI / WE-EF Eco Step Dim® Dynamic
Class I Phase to L1, Neutral to N and Earthing to ,
1-10V, DALI, DMX to
+ and 1-10V, DALI, DMX to
7) Reposition gear box cover B and tighten screws C evenly.
8) Loosen the two screws G slightly. Aim luminaire in
desired direction, tighten screws G firmly (100Nm). In addition, tighten screw H to secure orientation of luminaire.
Notice: In case the luminaire is equipped with an optionally available surge protector, the function can get tested if the signal LED is lit green when the supply voltage is turned on.
In case the surge protector is defective, the LED device gets automatically disconnected fr
om the mains supply.
If the signal LED is not lit, the luminaire is not functioning.
Loading...