308-PA/..-402, 308-PAG/..-402
Distribution block
Tab connections 5 x 6,3; incl ined
4
4
,
,
4
11 6,3
11 6,3
28
28
23
23
10
10
ø 4,5
ø 4,5
L - 8
L - 8
L
L
Part Numbers
No. of
308-PA/.. -402 308-PAG/. . -402 Length PU
poles
1 11.885.402 11.888.402 30 250
2 12.885.402 12.888.402 41 200
3 13.885.402 13.888.402 52 200
4 14.885.402 14.888.402 63 100
5 15.885.402 15.888.402 74 100
6 16.885.402 16.888.402 85 100
7 17.885.402 17.888.402 96 100
8 18.885.402 18.888.402 107 50
10 20.885.402 20.888.402 129 50
12 22.885.402 22.888.402 151 50
further number of poles on request
4
37
37
General Information
No. of poles 1 - 16
Technical Data
Rated Insulation Voltage 450 V acc. to EN 60998-1
Rated Current acc. to DI N EN 61210:
12 A with receptable 6, 3; wire 1,5 mm²
15 A with receptable 6, 3; wire 2,5 mm²
18 A with receptable 6, 3; wire 4 mm²
20 A with receptable 6, 3; wire 6 mm²
Material
Moulding PA, natural, V-2
Comparative Tracking Index CTI 250 (CTI 400)
Insulating Group IIIa (II)
Temperature Range RTI Str 90°C (130°C PAG-Version)
Tab Zinc plated st eel
(PAG-Version: PA glass f iber reinforced, natural,
V-0)
Details in round brack ets apply for "no flame"
products
Approvals
Current [A] Voltage [V] Group AWG [Nm]
20
10
Current [A] Voltage [V] [mm²]
17,5 450 1,5
300
300
B
D
Options / Accessories
Consecutive number ing
•
Special marking according t o drawing
•
Fixed marking in t he t ool on request
•
''no flame'' aft er glow-wire test according to
Household Appliance DIN EN/IEC 60335- 1