Web Dynamics TLX Silver Multi Foil User Manual

TLX Silver Multi Foil
Key Factors Assessed
Validity
This
Issue Dated
Certificate No:
Description of Product
EWW42A
build and refurbished roofs, and timber frame
and masonry walls.
Safety in case of Fire
Health, Hygiene and Environmental
Energy Economy and heat retention
Durability serviceability and identification
Photo/isometric drawing
provided by manufacturer
certificate was first issued on 23rd July 2010 and is valid until 4th August 2020
13th May 2020
Insulation Product Type
Test Method
Thermal conductivity (λ)
Emissivity
Water vapour resistance
Fire performance
Product Thickness
Core RD value (thermal resistance)
Core RD value with 1 air spaces
1.81
M2K/W
Air space thickness
13
mm
Direction of heat flow when tested
Vertical
Width
Weight
Roll length
This Registered Detail relates to TLX Silver Multi Foil Insulation. It is for use in new build and refurbished roofs, and timber
frame and masonry walls. The product must be installed in strict accordance with the manufacturer’s details. To achieve the
minimum requirements of Approved Document L, a secondary insulation product will be required unless relaxations apply.
1
ISO 8302:1991
0.033 W/m/K
0.05
740 MNs/gm
Class D
30 mm
0.91 M2K/W
1.2 m
545 g/m2
10 m
The insulation should not be carried over the junctions between roofs and walls required to provide a minimum period of fire
resistance.
Installation to be in strict accordance with manufacturers guides and recommendations and supported by relevant U-value
calculations incorporating material thermal properties as declared.
Appropriate thermal analysis will be provided in each instance to demonstrate continued compliance with Approved Document L
2010 / 2013. To achieve the minimum requirements of Approved Document L, a secondary insulation product will be required
unless relaxations apply.
LABC consider that TLX Silver will meet the functional requirements of the Building Regulations (listed
below) if the criteria detailed in this certificate are met;
The Building Regulations 2010 (as amended) England & Wales
Regulation 7 Materials and workmanship
Note: The products are acceptable.
AD B Fire Safety
Note: The products can contribute to meeting this Requirement subject to limitations
detailed in Conditions section.
AD C Resistance to Contaminants and Moisture
Note: The products can contribute to meeting this Requirement subject to limitations
detailed in Conditions section.
AD L Conservation of Fuel and Power
Note: The products can contribute to meeting this Requirement subject to limitations
detailed in Conditions section.
The Building Regulations 2010 (as amended) England
None presently
The Building Regulations 2010 (as amended) Wales
None presently
The Building (Scotland) Regulations 2004 (as amended)
If you would like to discuss a specific use of the product in Scotland it will require an additional
assessment under the Scottish Building Regulations and accordingly you should contact the LABSS
STAS Administrator at www.labss.org
LABC Warranty
This product confirms to the Functional Requirements of the LABC Warranty Technical Manual.
BBA Agreement Certificate 06/4379 (Thinsulex Silver & TLX Silver for Timber
Frame & MasonryWalls).
BBA Test Report No 5957 TLX Silver & TLX Silver FB Insulation (Emissivity) BTTG Fire Technology Fire Test Report TLX Silver 3rd
March 2008
BBA Test Report No 5908A Thinsulex Silver (Thermal Resistance)
Chiltern International Fire Test Report Ref Chilt/A08118 TLX Multi Foil Insulation fire test report (timber frame wall construction)
U Value Calculations – Web Dynamics LTD
Trade Literature, Product information (Product details and practical application) TLX Technical Manual – TLX Multi Foil
insulation product literature, standard details and technical information (Version 2011.1)
Web Dynamics Ltd
Moss Lane
Blackrod
Bolton
Lancashire
BL6 5JB
Tel:
Email:
Web:
01204 695 666
tlx@webdynamics.co.uk
www.webdynamics.co.uk
Loading...