Waystream ASR6000, ASR6126, ASR6026, ASR6326, ASR6226 Installation Manual

ASR
Advanced Services Router
ASR 6000 Installation Guide
ASR 6000 Installation Guide
ASR 6000 Installation Guide
Copyright and Legal notice
Copyright 2012-2016 Waystream AB. All rights reserved.
iBOS, the ASR Bootloader, program models and other software content and this documentation (“the Intellectual Property Rights”) are protected by the Swedish Copyright Act (Sw: Upphovsrättsla­gen) and, if applicable, the Swedish Patents Act (Sw: Patentlagen). All and any copying and dis­tribution of the Intellectual Property Rights, without authorization by Waystream is prohibited. The prohibition includes every form of reproduction and distribution.
Every effort was made to ensure that the information in this document was complete and accurate at the time of printing. However, information is subject to change without notice. Waystream as­sumes no liability for damages incurred directly or indirectly from errors, omissions or discrepancies between the software and this document.
iBOS, ServiceEngine, MS4000-series switches and ASR are trademarks of Waystream.
All other trademarks, service marks and trade names are proprietary to their respective owner.
Purchasers, licensees and users accept and acknowledge that the products contain components (including components carrying certain firmware) and combinations of components that constitute trade secrets protected by Waystream or its partners. Purchasers, licensees and users warrant that the delivered products will not be opened or dismantled, copied, altered or in any other way mod­ified. Furthermore, purchasers, licensees and users agree not to attempt to reverse engineer, dis­assemble, modify, translate, create derivate works, rent, lease, loan, or without written permission distribute or sublicense the software, in whole or in part.
The products and its hardware, firmware and software, including technical data, may be subject to EU and U.S export control laws, including the U.S Export Administration Act and its associated regulations and the International Traffic in Arms Regulations administerd by the US Department of State, and may be subject to export or import regulations in other countries. Purchasers and li­censees agree to comply strictly with all such regulations and acknowledges that it has the re­sponsibility to obtain licenses to export, re-export, or import hardware, firmare and software.
Purchasers and licensees are not entitled to, and Waystream is not in any event liable to pay, compensation for damages which delivered products or software has caused to other property or to persons or any other consequential damages, including but not limited to loss of profit, loss of production or any other indirect damages.
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ASR6026 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
ASR6126 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ASR6226 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
ASR6326 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
The ASR6000 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
LED Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Console Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ASR6000 Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
ASR6000 Ground Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Installing the ASR6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Tools Required. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Safety Guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
General Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Lithium Battery Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Operating Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
EMC Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Equipment List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
ASR6000 Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Ventilation of ASR6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Rack Installation of ASR6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Connecting Power to the ASR6000. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Installing SFP Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Connecting the ASR6000 to the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Checking the ASR Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Connecting to the Console Interface Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
The Boot Process. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Troubleshooting the Bootloader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
No uplink during Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
No valid iBOS Image during Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Troubleshooting iBOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Check System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Check Available Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Check SFP Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Check the Uplink Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Check OSPF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Check CSAR Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Appendix A – ASR6000 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ASR Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Interface Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Power and Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Appendix B – SFP Products for ASR6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Insertion and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Inserting an SFP module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Removing an SFP Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
3
Introduction
The Advanced Services Router (ASR) series 6000 is a versatile accesslayer switch for broadband networks. The router is available in two models with different interface types that makes it possible to use the ASR6000 for all types of network access solutions.
This manual is intended for persons installing ASR6000 units in a network. You will need to be familiar with the Waystream products including iBOS, and the hardware used in your networking system.
After reading this manual, you will be able to install, power up and handle basic troubleshooting of the ASR60000 series routers.
This manual describes the following:
• “Product Overview” on page 5
• “Installing the ASR6000” on page 15
• “Checking the ASR Installation” on page 23
• “ASR6000 Product Description” on page 31
• “SFP Products for ASR6000” on page 33
For complete information of the product, including specifications for hardware and software functionality, refer ASR6000 Product Specification.
For more information on configuring the boot options of the ASR6000, refer ASR6000 Bootloader User Guide.
ASR 6000 Installation Guide
4
5
Product Overview
This chapter provides an overview of the ASR6000 for installation purposes only.
For a complete specification of the product, refer “ASR6000 Product Description” on page 31.
Figure 1 ASR6000 Series Switch
The ASR6000 is designed for installation in a standard 19” rack.
ASR 6000 Installation Guide
6
Product Models
The ASR6000 series switches are fancooled, and are designed for central office environments.
This installation guide covers the following models of the ASR6000 series router.
• ASR6026
• ASR6126
• ASR6226
• ASR6326
ASR6026
The ASR6026 has the following interfaces:
• Two (2) 10 GigabitEthernet SFP+ uplink ports
• One (1) RJ45 serial console port
• Twenty Four (24) GigabitEhernet SFP downlink slots
• Four (4) RJ45 combo ports
The ASR6026 is available as an AC model.
Figure 2 ASR6026
The 24 GigabitEthernet interfaces are capable of running 100/1000 Mbps on fibre cables. In addition, there are four RJ45 interfaces that can be used with twisted pair (TP) Category 36 UTP/STP cables.
Product Overview
7
ASR6126
The ASR6126 series has the following interfaces:
• Two (2) 10 GigabitEthernet SFP+ uplink ports
• One (1) RJ45 serial console port
• Twenty Four (24) GigabitEhernet RJ45 downlink ports
• Four (4) SFP combo ports
The ASR6126 is only available as an AC model.
Figure 3 ASR6126
The 24 GigabitEther interfaces are RJ45 ports that are capable of running 10/100/ 1000 Mbps on twisted pair (TP) Category 36 UTP/STP cables. In addition, there are four SFP combo ports that can be used with fiber connectors at 100/1000 Mbps.
ASR6226
The ASR6226 has the following interfaces:
• Two (2)10 GigabitEthernet SFP+ uplink ports
• One (1) RJ45 serial console port
• Twenty Four (24) GigabitEhernet SFP downlink slots
• Four (4) RJ45 combo ports
The ASR6226 is available as an AC model.
Figure 4 ASR6226
ASR 6000 Installation Guide
8
ASR6326
The ASR6326 series has the following interfaces:
• Two (2) 10 GigabitEthernet SFP+ uplink ports
• One (1) RJ45 serial console port
• Twenty Four (24) GigabitEhernet RJ45 downlink ports
• Four (4) SFP combo ports
The ASR6326 is only available as an AC model.
Figure 5 ASR6326
Product Overview
9
The ASR6000 Front Panel
All connectors are placed in the front of the ASR for easy operation. There is also an LED panel that shows the status for all interfaces and the power supply.
Figure 6 ASR6000 Front Panel
LED Panel
The LED panel shows the status of the power supply, system status, remote management, as well as for the uplink and downlink interfaces.
Figure 7 ASR6000 LED panel
Uplink Interfaces
Downlink Interfaces
LED Panel
Console Interface
Power Connector
ASR 6000 Installation Guide
10
System LEDs
The ASR6000 has three LEDs for showing system status; POWER, SYSTEM and MANAGED. Refer for more information.
Figure 8 System Status Indicators
Table 1 System Status LED Status
LED STATE Description
POWER OFF
ON
FLASHING
Power is OFF
Power is ON.
ASR is overheating.
SYSTEM OFF
ON
FLASHING
System is not loaded
System successfully booted.
System is booting
MANAGED OFF
ON
FLASHING
iBOS has started
Connected to remote management system
Manual configuration
Product Overview
11
LED for Uplink Interfaces
For the uplink interfaces, the unit has two slots for SFP+ modules that can reach speeds of upto 10 Gbps. Read more about the SFPs in “SFP Products for ASR6000” on page 33.
Figure 9 Uplink LEDs
When an uplink interface is active, the status is shown on the LED panel. See the table below
Table 2 Uplink LED Status
10 GE LED STATE Description
12 OFF
ON
FLASHING
No uplink established
Uplink is established GREEN=10 Gbps AMBER= 1 Gbps
Uplink port is active, packets sent on port GREEN= 10 Gbps AMBER=1 Gbps
ASR 6000 Installation Guide
12
LED for Downlink Interfaces
For the downlink interfaces, the unit has 24 LEDs. Each number corresponds to the respective downlink port.
Figure 10 Downlink LEDs
Depending on the model and usage of the combo ports, these interfaces can operate at 10, 100 or 1000 Mbps. See the table below for a description of the different states:
Table 3 Downlink LED Status
GIGABITETHERNET LED
STATE Description
124 OFF
ON
FLASHING
No downlink established.
Downlink is established GREEN= 1 Gbps AMBER=10100 Mbps
Downlink port is active, packets sent on port GREEN= 1 Gbps AMBER=10100 Mbps
Product Overview
13
Console Port
The ASR6000 has one serial console port for management of the unit that is able to operate from 9600 to 115200 bps. The connector type is RJ45. Default speed is 115200 bps, but can be changed through the command line interface of the Bootloader or iBOS software. Refer “ASR6000 Bootloader Configuration Guide” and/or the bootloader section of the “iBOS Command Reference Guide” for more information.
To connect to the console port, a RS232 RJ45 to 9 pin DSub cable is supplied.Your terminal software should be configured to 8 data bits, no parity and 1 stop bit (8N1). No flowcontrol or hardware flowcontrol (RTS/CTS) should be used.
ASR6000 Power Connector
The power connector is located at the front of the ASR6000. A standard IEC C13 EU power cable is supplied.
Figure 11 ASR6000 AC Power Connector
ASR 6000 Installation Guide
14
ASR6000 Ground Connector
If required, a ground connector screw is located on the back of the ASR. Using the ground screw and washer supplied, fasten the ground cable to the chassis in the following way:
1. Loosen the ground terminal screw
2. Attach the lug of the grounding cable between screw and washer and ensure that the
other end of the grounding cable is connected to GND
3. Tighten the screw and check that the grounding cable is securely fixed to the chassis.
Figure 12 Attach Grounding Cable to ASR6000 Chassis
Warning
• Connect the ASR casing to earth before the ASR is powered ON for the first time,
• Proper grounding (connection to earth) is very important to protect the ASR from bad effects of external noise and to reduce the risk of electrocution in the event of a direct lightning strike.
• For removal of the ASR, disconnect the grounding cable after the power is switched OFF and all other cables are disconnected.
• For the earthing wire, green and yellow insulation is required and the crosssectional
area of the conductor must not be less than 0.75 mm
2
or 18 AWG.
Screw
To Earth
Earthing Wire
15
Installing the ASR6000
Tools Required
The ASR6000 does not include any tools required to install the units. Appropriate screwdrivers, ratchets etc. must be obtained elsewhere.
To complete this installation, the following extra materials are also needed:
• 10 GigabitEthernet (SFP+) or GigabitEthernet (SFP) modules for uplink ports
• 12 patch cables, fibre for uplink ports
• GigabitEthernet SFP modules (depending on model)
• 124 patch cables, UTP/STP or SC/LC fibre for downlink ports (depending on model)
Safety Guidelines
Follow these guidelines to ensure the required level of safety.
General Safety
• Keep the chassis area clear and dustfree during and after installation.
• Do not wear loose clothing or jewellery that could get caught in the chassis. Fasten your tie or scarf and roll up your sleeves.
• Wear safety glasses if you are working under any conditions that might be hazardous to your eyes.
• Do not perform any action that creates a potential hazard to people or that makes the equipment unsafe.
• Disconnect all power by turning OFF the power and unplugging the power cord before installing or removing a chassis or working near power supplies.
• Do not work alone if potentially hazardous conditions exist.
• Never assume that power is disconnected from a circuit; always check the circuit first.
ASR 6000 Installation Guide
16
Lithium Battery Safety
• There is a risk of explosion if the battery is replaced with the incorrect type.
• Dispose of used batteries according to manufacturer instructions
Operating Safety
• Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment to acceptable operating temperatures without adequate circulation. Be sure that the room in which you choose to operate your system has adequate air circulation.
• Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An open chassis permits air leaks, which may interrupt and redirect the flow of cooling air from internal components.
• Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when electronic components are improperly handled and can result in complete or intermittent failures. Be sure to follow ESDprevention procedures when removing and replacing components to avoid these problems.
• Wear an ESDprevention wrist strap, ensuring that it has good skin contact, If no wrist strap is available, ground yourself by touching the metal part of the chassis.
• Periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megaohms.
EMC Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to EN 55022. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with this document, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case owners will be required to correct the interference at their own expense.
Installing the ASR6000
17
Equipment List
The following table lists the typical quantities of items supplied with each ASR6000 unit.
• ASR6000 unit
• One (1) 180 cm EU power cable with mains plug
• One (1) 180 cm RS232 cable (DB9 female to RJ45)
• Rack kit (preinstalled) including;
–Two (2) angle brackets
– Eight (8) screws for angle bracket
– Four (4) cage nuts and screws (M6) with plastic washers
• Grounding kit including:
– Two (2) screws for grounding (M5) with lock washers
ASR 6000 Installation Guide
18
ASR6000 Environment
The ASR6000 is designed to be mounted in a 19inch rack in a restricted access location. For restricted access locations, the following applies:
• Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken
• Access is through the use of a TOOL or lock and key, or other means of security, and controlled by the authority responsible for the location
The ASR is designed to be mounted in a single shelf of a 19inch rack. The cooling fans are located on the side of the unit so ventilation must be available to allow free airflow so that the fans can maintain a persistent and satisfactory ambient temperature.
Figure 13 ASR6000 in Rack
For rack installations, the following considerations must be taken:
Elevated Operating Ambient Temperature
 When installed in a closed or multi
unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient. Therefore, consideration should be given to installing the equipment in an rack environment compatible with the maximum ambient temperature, refer “ASR6000 Product Description” on page 31
Reduced Air Flow
 Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
Mechanical Loading
 Mounting of the equipment in the rack should be such that
a hazardous condition is not achieved due to uneven mechanical loading.
Circuit Overloading
 Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Earthing
 Reliable earthing of rackmounted equipment should be
maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Installing the ASR6000
19
Ventilation of ASR6000
The ASR6000 is cooled by three builtin fans. Ensure that air can flow freely from righttoleft in the cabinet. To extend the lifetime of the fans, ensure that the air is filtered and free from dust particles.
Rack Installation of ASR6000
As shown in Figure 13, multiple ASR6000 units can be mounted in a 19inch rack on top of each other. All connectors are located in the front of the ASR6000 for easy access.
The rack brackets are preattached for fast installation. When the ASR is installed, the front panel will be flush with the front of the rack frame, see Figure 14.
Figure 14 Default Rack Bracket on ASR
For cabinets with doors that require more space for cables etc. in front of the unit, it is possible to remove the four bracket screws and reposition the brackets using the extra screwholes to provide 25 mm space in front of the ASR, see Figure 15.
ASR 6000 Installation Guide
20
Figure 15 Rack Bracket Installed for Extra Space
To install the ASR in the rack, hold the ASR6000 firmly in position and use the supplied screws and nut baskets to fix the unit in the 19inch rack space.
Connecting Power to the ASR6000
The information below is valid for all ASR6000 units.
The ASR6000 runs on 110/240V 5060Hz AC. Installation of 110/220V mains power outlets must be performed by a licensed electrician.
Warning
The ASR6000 unit must be connected to ground before power supply units, computers or other electrical or electronic equipment is connected to the ASR6000 (including the serial console port).
Installing the ASR6000
21
Power ON
When the mains power is connected to the ASR6000, the ASR6000 will automatically boot and attempt to establish the uplink connection with the network. To prevent any sudden power surges at startup, it is recommended to have a separate ON/OFF switch for the main power supply.
To power up the ASR, do the following:
1. Connect the mains power cable to the ASR power connector.
2. Connect the mains power cable to the power socket.
3. If there is an ON/OFF switch, then flip the ON/OFF switch to ON.
The ASR6000 power LED will now light up.
Note: The fans take 56 seconds before starting.
Installing SFP Modules
The ASR6000 is designed to use Small Form Factor Pluggables (SFP+) modules for 10
GigabitEthernet uplinks. For information about insertion and removal of SFP+
modules and important safety information, please ref er “SFP Products for ASR6000”
on page 33.
Connecting the ASR6000 to the Network
In most network topologies, the 10 GigabitEthernet SFP+ modules will be used as uplinks, connecting the ASR6000 to the network.
Connecting Uplink Interfaces
To connect the uplink interfaces to the ASR:
1. Select the appropriate patch cables for the SFP modules installed.
2. Remove dust cover on SFP and connect the patch cable to the SFP
3. Connect the patch cable to the network fibre patch panel or fibre connector
If the ASR establishes an uplink, connection the uplink LED will light up.
ASR 6000 Installation Guide
22
Connecting Downlink Interfaces
Determine what type of downlink interfaces are used by the unit. Depending on the ASR model, different connectors and cable types are used.
1. Connect the patch cables to the ASR6000 interfaces,
2. Connect the patch cable to the network patch panel
If the ASR6000 has received configuration and there are client devices connected at the subscriber side of the connection, the LED panel will indicate that link is present on the GigabitEthernet interface.
Table 4 Downlink Interfaces
Model Patch cable type ASR6000 connector type
ASR6026 Category 5e or Cat6 Twisted Pair (TP) RJ45
ASR6126 Depending on type of SFP SFP (refer “SFP Products for
ASR6000” on page 33
23
Checking the ASR Installation
The ASR6000 router has a console interface that is used to view configuration information when the ASR is running. During the boot process, the ASR outputs information about the boot progress, and if any problems are encountered.
Figure 16 Console Interface
To connect to the console port, you need the RJ45 to 9 pin DSub cable supplied with the unit.
Connecting to the Console Interface Port
1. Connect your terminal to the console port using the supplied cable.
2. Configure your terminal software using the following settings:
– 8 data bits, no parity and 1 stop bit (8N1)
– No flowcontrol or hardware flowcontrol (RTS/CTS)
– 115200 bps send rate
ASR 6000 Installation Guide
24
The Boot Process
When the power is first turned on, the ASR6000 immediately starts the bootloader software. The bootloader performs basic system initialization, decompresses, and runs the iBOS software image that is stored on flash memory. The boot process can be followed on the console.
1. The Bootloader locates a bootable image either on the flash memory (if it exists), or
in the network if BOOTP options provided to the ASR by the network so indicate. The image is compressed to conserve file system space, and must therefore be decompressed when read into memory. The Bootloader displays the following message when it is decompressing the iBOS image:
Decompressing ibos-asr6k-6.1.0-ED-R.bz2 (press any key to abort)
Note:
The local filename of the image being decompressed is displayed, e.g. the image filename is ibosasr6k6.1.0EDR.bz2.
2. When the iBOS image has been loaded into RAM, the Bootloader will start the
main software. The following message is displayed:
Running ELF executable at address: 0x80200000
Troubleshooting the Bootloader
When a terminal is connected to the ASR console port, pressing any key aborts the boot process and enters the bootloader command line interface. Situations where the bootloader fails to complete the boot process are:
• If the boot process is looping, it may be necessary to download new software or to make changes to the boot configuration if the ASR is not able to complete the boot process.
• If there is no valid iBOS image on the flash file system, the boot process will continue to loop until there is an active uplink and contact is established with a boot server.
No uplink during Boot
If the boot process is looping because of no link on the uplink interfaces, the bootloader will print the following to the terminal:
.. Autoboot in progress (press any key to abort). Scanning boot image information on flash. No image found. Trying BOOTP over tengigabitethernet1 and tengigabitethernet2. No link on tengigabitethernet1. No link on tengigabitethernet2. BOOTP failed. Retrying BOOTP (press any key to abort). Trying BOOTP over tengigabitethernet1 and tengigabitethernet2. No link on tengigabitethernet1.
Checking the ASR Installation
25
No link on tengigabitethernet2. BOOTP failed.
Retrying BOOTP (press any key to abort). ...
The example above shows that no link was detected on the tengigabitethernet1 or tengigabitethernet2 interfaces. Check that the SFP is properly inserted and that the fiber is connected. If no problem can be found in the connections the probable cause is the other end of the fiber.
No valid iBOS Image during Boot
If a default image is found in the flash file system and one BOOTP attempt fails to get a new image name from the boot server, the selected image is booted (or if it is damaged the newest image found on the flash is used instead). The following text is printed on the terminal
.. Autoboot in progress (press any key to abort). Scanning boot image information on flash. Found image version ibos-asr6k-6.1.0-ED-R Trying BOOTP over tengigabitethernet1 and tengigabitethernet2. BOOTP failed.
Decompressing ibos-asr6k-6.1.0-ED-R (press any key to abort). ...
If no image is selected for default boot, but at least one image is found and no connectivity with boot server is acquired within ten BOOTP attempts, the newest image found on the flash is booted. The following text will be printed on the terminal
... Autoboot in progress (press any key to abort). Scanning boot image information on flash. Found fallback image version ibos-asr6k-6.0.1-ED-R Trying BOOTP over tengigabitethernet1 and tengigabitethernet2. BOOTP failed. Retrying BOOTP, 9 attempts left. ... Retrying BOOTP, 2 attempts left. Trying BOOTP over tengigabitethernet1 and tengigabitethernet2. BOOTP failed. Retrying BOOTP, 1 attempts left. Trying BOOTP over tengigabitethernet1 and tengigabitethernet2. BOOTP failed. No file to boot. Trying to find another image to boot. Booting ibos-asr6k-6.1.0-ED-R.
Decompressing ibos-asr6k-6.1.0-ED-R (press any key to abort). ...
For more information on the Bootloader CLI, refer ASR6000 Bootloader User Guide.
ASR 6000 Installation Guide
26
Troubleshooting iBOS
The iBOS software is the ASR operating system that enables services and also has internet connection features. When connected to the ASR using the console port or the management port, an iBOS command line interface appears after a successful boot process.
Access to iBOS command line normally requires login. There is no default username or password configured, and if the ASR is unconfigured simply press the Enter key when prompted for username and password.
Note: If local or remote user authentication has been configured in the ASR, the correct
username and password must be used to gain access to the command line interface via the console port.
The command line interface displays the ASR6000 hostname (if configured), the CSAR connection status, the system uptime etc.
Check System
To display the system information, use the show version command. The information displayed includes the version of iBOS running in the system, the system hostname and uptime, the model and characteristics of the ASR6000, its serial number, and other information.
Example 1 show version
asr6k> show version Intelligent Broadband Operating System (iBOS), Version 6.1.0-ED-R Copyright (c) 2012-2016 by Waystream AB Routing Engine Copyright (C) 2001-2009 IP Infusion, Inc. Compiled Fri Jan 13 02:17:56 CET 2012 by builder Source ID: 34cb4619b322a417e097832b2a55145e05ce9bd0
asr6k uptime is 1 day, 17 hours, 35 minutes Last boot: cold start
System image file is "ibos-asr6k-6.1.0-ED-R.bz2", version ibos­asr6k-6.1.0-ED-R System: ASR6126C-CO, 2 1/10GE SFP+, 20 10/100/1000BaseTX ports, 4 BaseTX/SFP combo, Central Office AC Bootloader version: asrboot-asr6k-3.5.0-R-dbg Board revision: 0 Product ID: FJG042MN Serial number/Base MAC address: 0008AE860440 Processor: CN6230 [pass 2.2] (mipseb) 262144K bytes CPU RAM
Automatic exception dump server 10.66.110.10:10000 asr6k>
Checking the ASR Installation
27
Check Available Devices
The PFDP protocol is exchanged between all Waystream network products. The iBOS command show pfdp neighbours displays a summary of all known Waystream devices that are connected this system. The information is valuable to identify what other PFDP enabled devices (ASR, SE, DRG, CPS etc.) are connected to this system.
Example 2 show pfdp neighbours
asr6k> show pfdp neighbours gigabitethernet23 with 1 neighbour(s): "DRG800" running "drgosl-drg800-1.1.0-RC3" on model "DRG886" remote interface uplink1, last activity 0s ago, unidirectional
gigabitethernet24 with 1 neighbour(s): "DRG508s_MK1" running "DMA0081-R2N20" on model "DRG508s_MK1" remote interface wan1, last activity 53s ago, unidirectional
tengigabitethernet1 with 1 neighbour(s): "Small-BTU1-2" running "iBOS 3.21.4-ED-R" on model "ASR4124C" remote interface gigabitethernet2, last activity 22s ago, bidirectional
tengigabitethernet2 with 1 neighbour(s): "Small-BTU1-8" running "iBOS 6.1.0-ED-RC2" on model "ASR5124C-CO" remote interface gigabitethernet1, last activity 28s ago, bidirectional
asr6k>
Check SFP Interface
To examine the SFP statistics on the uplink interface, use the iBOS command show
interface sfp
for one of the uplink interfaces. (Pay special attention to the TX/RX input/
output power details).
Example 3 show interface sfp
asr6k# show interface tengigabitethernet1 sfp Small Form-factor Pluggable (SFP) at tengigabitethernet1 LC connector 10000-SR capable 64B/66B encoding, nominal bitrate: 10300 Mbps Supported links 50um multi mode fiber: 80 m
62.5um multi mode fiber: 30 m
Laser wavelength: 850 nm
Diagnostics Normal Warning Entity Status Unit Current Low High Low High
------------------------------------------------------------------
--------
Operating temp: OK C 40.88 -3.00 73.00 -5.00
75.00
ASR 6000 Installation Guide
28
Supply voltage: OK V 3.27 3.14 3.47 2.97
3.63
TX current: OK mA 5.30 2.00 11.00 1.00 12.00 TX output power: OK mW 0.55 0.32 0.66 0.25
0.83
RX input power: ALRM(L) mW 0.00 0.02 0.79 0.01
1.00
asr6k#
Check the Uplink Interface
To check that the uplink interface gets an IP address from the network boot server, use the command show ip bootp.
Example 4 show ip bootp
asr6k> show ip bootp BOOTP Client state: Standby mode: Persistent serial: 0008.ae86.0440 protos: http,tftp version: ibos-asr6k-6.1.0-ED-R
Interface tengigabitethernet2 BOOTP mode is Standby, interface is Up Last assigned: 10.130.1.29/30 gateway 0.0.0.0 server 10.66.110.10 (1D17h49m41s ago) Packet counters: 1 sent, 1 received 0 dropped due to erroneous data 0 dropped because we couldn't comply 0 with matching addresses, 1 used assignments
Interface tengigabitethernet1 BOOTP mode is Standby, interface is Up Last assigned: 10.130.1.2/30 gateway 10.130.1.1 server
10.66.110.10 (1D17h49m40s ago)
Packet counters: 1 sent, 1 received 0 dropped due to erroneous data 0 dropped because we couldn't comply 0 with matching addresses, 1 used assignments
asr6k#
Checking the ASR Installation
29
Check OSPF
To check that OSPF Routing is functioning properly, display the active OSPF processes with the command show ip ospf neighbor.
Example 5 show ip ospf neighbor
asr6k# show ip ospf neighbor OSPF process 0: Neighbor ID Pri State Dead Time Address Interface
------------------------------------------------------------------
--------------
10.130.0.1 1 Full/Backup 00:00:37 10.130.1.1
tengigabitethernet1
10.130.0.5 1 Full/DR 00:00:35 10.130.1.30
tengigabitethernet2
Check CSAR Connections
To check CSAR connection for a BECS3 network and to ensure there is a service provision, use the command show csar.
Example 6 show csar
asr6k# show csar Server Address State Flags
------------------------------------------------------------------
--------------
em-ibos@small-.. 10.66.110.10 Up Connected,Learned
Active server: em-ibos@small-cell-1-p
ASR 6000 Installation Guide
30
31
Appendix A – ASR6000 Product Description
This appendix describes product details for specific models that may be required while installing the ASR.
ASR Interfaces
Two SFP+ module slots for 10 GigabitEthernet uplink ports (all models)
24 SFP module slots for GigabitEthernet downlink ports (6026 only)
Two RJ45 combo ports for GigabitEthernet downlink ports 2124 (6026 only)
24 RJ45 GigabitEthernet downlink ports (6126 only)
Two SFP module slots for GigabitEthernet combo ports 2124 (6126 only)
Interface Specification
For a detailed specification and pictures of the interfaces for each specific model, refer “Product Overview” on page 5.
ASR 6000 Installation Guide
32
Technical Data
Physical Dimensions
Table 1 Physical Dimensions
Power and Safety
Single power input 100 – 240V, 50 – 60 Hz, compliant with ETSI EN 300132
V2.1.1 Part1.
CE mark
IEC/EN/UL 60950
IEC/EN/UL 60826
CB certificate
ETSI EN 300386
FCC Part 15 Subpart B
RoHS directive 2002/95/EC
Environmental
All ASR6000 models:
Operating temperature: 0° to 45° C
Storage temperature: 10° to 70° C
Operating humidity: 5% to 95%, noncondensing
Heat dissipation: max 46 watts
ASR6000CO
H*W*D (mm) = 43 x 441 x 240
Weight: 4 kg
Standard 19inch rack mounting
33
Appendix B – SFP Products for ASR6000
Overview
The Waystream SFP (Small Formfactor Pluggable) GigabitEthernet products are a series of optical transceiver modules that enable the ASR to be fitted with suitable network interfaces for different needs.
Using standardized safety requirements, the modules are certified for use together with the Waystream products.
Waystreamapproved SFP modules have a serial EEPROM that contains the module serial number, the vendor name and ID, a unique security code, and cyclic redundancy checksum (CRC).
This manual does not describe the full product specifications for all approved SFP modules. Model and data for Waystream SFPs is listed in separate data sheets. The SFPs named in this document are used for examples only, and are not ranked in any preferential order.
All Waystream SFPs have baleclasp latches for safe operation.
Figure 1 SFP with baleclasp Latch
ASR 6000 Installation Guide
34
Table 2 Waystream SFP Products
Note: The selection of Waystream SFP products is being constantly improved, please
contact your local sales representative for an uptodate list of Waystream approved SFPs.
When the SFP is inserted in the ASR, the ASR software reads the EEPROM to check the serial number, vendor name and ID, and recomputes the security code and CRC.
The SFP also provides link status information and other valuble statistics to determine the operation and quality of the connection to the adjacent device. This information is displayed using the iBOS command show interface sfp.
Caution
Use of nonWaystream approved SFPs will void the product warranty.
Waystream SFP Product Name
Wavelength Connector Fibre type Speed
(Mbps)
SFP1000BASEBXD TX:1490nm
RX:1310nm
SC Simplex Single mode 1000
SFP1000BASEBXU TX:1310nm
RX:1490nm
SC Simplex Single mode 1000
SFP1000BASEBX10 D1550LC
TX:1550nm RX:1310nm
LC Simplex Single mode 100/1000
SFP1000BASEBX10 D1550SC
TX:1550nm RX:1310nm
SC Simplex Single mode 100/1000
SFP1000BASEBX10 U1550LC
TX:1310nm RX:1550nm
LC Simplex Single mode 100/1000
SFP1000BASEBX10 U1550SC
TX:1310nm RX:1550nm
SC Simplex Single mode 100/1000
SFP1000BASELX 1310 nm LC Duplex Single mode 1000
SFP1000BASELXM 1310nm LC Duplex Single mode 100/1000
SFP1000BASESX 850 nm LC Duplex Multimode 1000
SFP1000BASESXM 850nm LC Duplex Multimode 100/1000
SFP1000BASET N/A RJ45 N/A 10/100/1000
SFP1000BASEZX 1550 nm LC Duplex Single mode 1000
SFP10GELR 1310nm LC Duplex Single mode 10000
SFP10GESR 850nm LC Duplex Multimode 10000
35
Safety
Before installing an SFP module or handling a Waystream broadband router equipped with SFP slots, you should read and understand the safety information in this document. Laser warnings only apply to fiberoptic SFP modules.
Figure 2 Warning symbol
Figure 3 Caution symbols
Warning
Class 1 laser product. Do not position your eye directly infront of the SFP if the dust plugs are not installed!
Warning
Laser beam is exposed when dust plug is removed and fiber not installed.
Warning
Only trained staff should install or replace SFPs.
ASR 6000 Installation Guide
36
Caution
SFPs are electronic devices and sensitive to static electricity. Always use an ESD preventive wrist strap when handling an SFP. ESD damages can cause performance and lifetime degradation.
Caution
Protect your fiberoptic components, like SFPs and cables, by inserting clean dust plugs when not connected to other equipment. Clean the optic components whenever you intend to connect them. Avoid getting dust and other contaminants into the optical receptacles, as fibre optics do not work correctly when obstructed with dust.
Caution
When using shorter distances of singlemode fiber cable, you may need to insert an inline optical attenuator in the link to avoid overloading the receiver. When the fiberoptic cable is less than 20 km and the link budget is more than 15dB, insert a 5 to 10 dB optical attenuator between the fiberoptic cable plant and the receiving port of the SFP.
Caution
Under no circumstances should the SFP insertion or removal require physical force. handling. Always be gentle and use only your thumb and index finger!
37
Insertion and Removal
When inserting or removing SFPs, always observe the following precautions:
Attach an ESDpreventive wrist strap to your wrist and to a bare metal surface on
the chassis or the common ground connector at the back of the module.
Hold the SFP modules by the side only and do not touch the connectors on the
insertion end of the module
Note: For other SFPs, please see the manufacturer instructions for installation and
removal.
Inserting an SFP module
1. Align the SFP module in front of the SFP slot. Note that the top side (with
Waystream sticker) faces up for upper row slots but faces down for lower row slots. This allows more space for connecting the cables to the SFPs.
2. Carefully slide the SFP module into the slot until you feel the connector on the
module snap into place.
3. Push the baleclasp latch up until it locks the SFP in position.
4. Remove the dust plugs from the cable and the SFP. Clean the connectors and the
SFP with dedicated fibre cleaning tools and carefully insert the cable(s) until they snap into place.
5. The SFP is now ready. The SFP state is indicated by the port LED
Note: Do not remove the dust plugs from the fiberoptic SFP module port or the rubber
caps from the fiberoptic cable until you are ready to connect the cable. The plugs and caps protect the SFP module ports and cables from contamination and ambient light.
Removing an SFP Module
1. Disconnect the cable from the SFP module and reinstall the dust plugs.
2. All Waystream SFPs have baleclasp latches. Gently pull the baleclasp latch out and
down until the SFP releases.
Note: For other SFPs, please see the manufacturer instructions for installation and
removal
3. Place the removed SFP module in an antistatic bag or other protective environment.
ASR 6000 Installation Guide