Wayne-Dalton 3750-372, 3014, 3651-372, 3012 User Manual

Photoelectric Safety Sensors
Installation Instructions
and Owner’s Manual
Wayne-Dalton Corp.
P.O. Box 67 Mt. Hope, OH 44660
(888) 827-3667
www.wayne-dalton.com
Quantum™/Classicdrive™ models: 3012, 3014, 3016, 3018, 3212, 3213, 3214, 3312, 3313, 3314, 3316, 3412, 3414, 3512, 3514.
DoorMaster™ models: BDOR-2000 & BIRW-2000
Opener Models:
Torsion idrive™ models: 3651-372, 3750-372.
WIRES ARE PRE-ATTACHED
Photoelectric Sensors Hardware: 297218
(2) 5/16 x 1-1/2” Lag Screws
(2) 1” Flat Head Nails
Photoelectric Sensors
(1) Sender w/Wire: 260600
(1) Receiver w/Wire: 260597
(2) 1/4-20 x 1/2” Carriage Bolts, Washers & Nuts
(2) Wall Mounting Brackets
(2) “U” Brackets
(1) Power Cord Clip (adhesive back)
(1) Jumper
Important Notice!
DOOR OPENER WILL NOT OPERATE PROPERLY UNTIL PHOTOELECTRIC
SENSORS ARE INSTALLED AND PROPERLY ADJUSTED! DO NOT OPERATE
DOOR OPENER UNTIL IT IS FULLY INSTALLED, ADJUSTED AND YOU ARE
INSTRUCTED TO DO SO!
© Copyright 2003 Wayne-Dalton Corp. New 9/4/2003
Part No: 306736
Table of Contents
Important Safety Instructions For Installation And Use 2. Bracket Installation 3. Wiring Installation “Quantum™/Classicdrive™” 4. Wiring Installation “DoorMaster™” 4. Wiring Installation “idrive™” 5. Wiring Installation “Torsion idrive™” 5. Photoelectric Safety Sensor Alignment 6. Photoelectric Obstruction Sensing Test 6. Important Safety Instructions 7. Warranty 7.
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
Customer Service Number 7.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO AVOID POSSIBLE INJURY OR DEATH.
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○○
○○○○○○○○○○○○
WARNING DISCONNECT ALL POWER FROM GARAGE DOOR OPENER BEFORE SERVICING
OR INSTALLING ACCESSORY PRODUCTS.
IMPORTANT SAFETY INSTRUCTIONS FOR
INSTALLATION AND USE
READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
DO NOT USE SENSITIVITY ADJUSTMENT TO COMPENSATE FOR A POORLY OPERATING DOOR. THIS WILL INTERFERE WITH THE PROPER OPERATION OF THE SAFETY REVERSE MECHANISM.
DO NOT CONNECT OPENER TO ELECTRICAL OUTLET UNTIL INSTRUCTED TO DO SO.
AFTER INSTALLING OPENER, THE DOOR MUST REVERSE WHEN IT CONTACTS A 1 INCH HIGH SOLID TEST OBJECT ON THE FLOOR.
OPEN DOOR MUST NOT CLOSE AND CLOSING DOOR MUST OPEN IF PHOTOELECTRIC SYSTEM IS OBSTRUCTED BY 6”X HIGH OBJECT, USING TEST PROCEDURE DESCRIBED IN STEP 4.
INSTALLATION AND WIRING MUST COMPLY WITH LOCAL BUILDING AND ELECTRICAL CODES. CONNECT THE POWER CORD TO A PROPERLY GROUNDED OUTLET. DO NOT REMOVE ROUND GROUND PIN FROM POWER CORD.
DO NOT WEAR RINGS, WATCHES OR LOOSE CLOTHING WHEN INSTALLING OR SERVICING A GARAGE DOOR SYSTEM. USE A STURDY, NONMETALLIC STEP LADDER AND WEAR EYE PROTECTION.
2
Step 1: Photoelectric Safety Sensor Bracket Installation
WARNING
GARAGE DOOR OPENER BEFORE SERVICING OR INSTALLING ACCESSORIES OR PHOTOELECTRIC SAFETY SENSORS. FOR ALL OPENERS, UNPLUG 120 V AC POWER CORD FROM RECEPTACLE. FOR DOORMASTER, ALSO UNPLUG TELEPHONE CORD TYPE COMMUNICATIONS CABLE.
DISCONNECT ALL POWER TO
“U” BRACKETS
Select a mounting position, no more than 5 inches above the floor to center line of wall mounting bracket. The sending and receiving units should be mounted inside the door opening to minimize any interference by the sun. However, the sensors should be mounted as close to the door track or inside edge of the door as possible to offer maximum entrapment protection. It is very important that both wall brackets be mounted at the same height for proper alignment.
The brackets may be temporarily mounted to the jamb with a 1” flat head nail (provided) using the small hole above the slot. Using two 5/16 x 1-1/2” lag screws (provided), permanently mount the wall mounting brackets to both door jambs. In some installations it may be necessary to attach a wooden spacer to the wall to achieve the required clearance.
Attach the “U” brackets to the wall brackets with a 1/4-20 carriage bolt, washer and nut (provided). Insert the bolt from the inside of the “U” bracket and hand tighten only at this time.
NUT
WASHER
(1) 5/16 X 1-1/2” LAG SCREW
(1)1/4-20 X 1/2” CARRIAGE BOLT
TAB HOLES TOP & BOTTOM
WALL MOUNTING BRACKETS
NAIL
5”
Identify which side of the garage door opening (if any) is “likely” to be exposed to sunlight. Since sunlight may affect photoelectric sensors, you should mount the sending unit (not the receiving unit) on the side of the door opening exposed most to the sun.
NOTE: If wires must be lengthened or spliced into prewired installation, use wire nuts or suitable connectors.
Attach the sending and receiving units to the “U” brackets by inserting their tabs into the respective holes.
3
TABS TOP & BOTTOM
RECEIVING UNIT
SENDING UNIT (NO LED)
LED ALIGNMENT LIGHT