I-DRIVE DISCONNECT HANDLE
Supplemental insert
This supplemental installation instruction is to be used as a supplement to the main Installation Instruction and Owner’s Manual provided with the door. The instructions included in
this document are ONLY those which deviate from the standard installation. All WARNINGS and CAUTIONS listed in the main manual are applicable to this supplemental instruction as
well.
© 2009 Wayne-Dalton Corp. Part No. 342295 NEW 5/29/2009
P.O. Box 67 Mt. Hope, OH 44660
www.wayne-dalton.com
1
Tools Needed:
NONE
Routing Disconnect Cable
Thread the disconnect cable through the hole in the right hand
end bracket down through the long slot in the horizontal leg of
the horizontal angle. Remove all slack between opener and
right end bracket.
Torquemaster
Disconnect
cable
®
Hole in right
end bracket
2
Routing Disconnect Cable
Tools Needed:
Pencil
Tape Measure
Power Drill
1/8” Bit
7/16” Socket
Driver
Mark a location on the right Jamb, 6 feet above the floor to
mount disconnect handle bracket.
Align top of the handle with the mark and mark location for
two lag screws.
Pilot drill lag screw location using 1/8” drill bit. Fasten bracket
to the jamb with (2) 1/4” x 1-1/2” lag screws.
Hole in right
end bracket
Torquemaster® Plus
Disconnect
cable
Hole in
right
side of
end
bracket
Hole in
right
side of
end
bracket
Disconnect
handle and
mounting
bracket
Disconnect
cable
Slot in
horizontal angle
(2) 1/4” X
1-1/2”
Lag screws
1
3
Attaching Disconnect Cable
Disconnect
cable
Tools Needed:
#2 Phillips
Screwdriver
Wire Cutters
4
Tools Needed:
None
With the Handle in the up position as shown, rotate the Cable
Stop/Pivot so the set screw is facing you. Route the
Disconnect Cable behind the Handle and through the hole in
the Cable Stop/Pivot (with the Set Screw facing you).
Position Handle in the full upper position and remove all cable
slack between the Opener and the Handle Bracket. Pull the
Disconnect Cable only enough to remove the Cable slack. Too
much tension could disconnect opener and cause failure to
reconnect.
Tighten the set screw using Phillips screwdriver to securely
clamp the disconnect cable. Trim off excess cable, as close as
you can, beyond bottom of the Cable Stop/Pivot.
Apply Emergency Disconnect Label next to the Disconnect
Handle Bracket. Use mechanical fasteners if adhesive will not
adhere.
Disconnect Handle Usage
Using the Emergency Disconnect, pull Disconnect
Handle downwards and place it in the manual door
operated position (disconnects door opener from door).
Return handle to the up position to re-connect opener to
the door.
Disconnect
handle
Full upper
position
Cable stop/pivot
Emergency disconnect label
Set screw
Disconnect
cable
Motor
operated
position
Manual
operated
position
Emergency
Disconnect
Label
2