Wayne PTU30, PTU33-A, PTU33, SSPTU33, SSPTU50 Operating Instructions And Parts Manual

...
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description
The pedestal pump is designed for home sump applications. The unit is equipped with an 8-ft long, 3-prong grounding type power cord. Motor is air cooled; it is not designed to operate under water. A float switch is provided for automatic pump operation. This pump is not suitable for aquatic life.
Unpacking
Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death.
Safety Guidelines
This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols.
Danger
indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Warning
indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Caution
indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Notice
indicates important information, that if not followed, may cause damage to equipment.
Operating Instruction and Parts Manual Pedestal Series
360513-001 6/07
General Safety Information
1. Read these rules and instructions carefully. Failure to follow these instructions could cause serious bodily injury and/or property damage.
Do not
submerge motor or allow motor to be exposed to water. Personal injury and/or death could result.
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Personal injury and/or death could result.
This pump
is not designed to handle salt water, brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials. Pump damage could occur if used in these applications and will void warranty.
All wiring
must be
performed by a qualified electrician.
If the basement has water or moisture on the floor, do not walk on wet area until all power is turned off. If the shutoff box is in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.
A battery
backup system should be used. Call 1-800-237­0987 to order an emergency backup system.
Assembly
Always disconnect the power source before attempting to install, service, relocate or maintain the pump. Never touch sump pump, pump motor, water or discharge piping when pump is connected to electrical power. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
1. Insert the float rod through hole in the switch lever (See Figure 1).
2. Place rubber grommet on float rod in temporary position.
3. Using pliers to hold the float rod, screw the float on as shown in Figure 1.
Pedestal Sump Pump
© 2007 Wayne Water Systems
Grommet
Guide
Float
Switch
Float
Rod
Figure 1
MANUAL
Notes Notas
Garantía Limitada
Wayne Water Systems (”Wayne“) le ofrece una garantía de 90 días a partir de la fecha de compra, para reparar o reemplazar, según lo decida la compañía, cualquier pieza de esta bomba para sumideros (“Producto”)que el comprador original envie a reparación y los empleados o representantes autorizados de Wayne determinen que están defectuosos debido a problemas de materiales o manufactura. Para recibir información sobre los pasos a seguir, comuníquese directamente con la compañía Wayne (800-237-0987, sólo desde EE.UU.), o con el distribuidor autorizado más cercano a su domicilio. En el momento de reclamar sus derechos bajo esta garantía deberá suministrarnos el número del modelo. Todos los gastos de flete serán la responsabilidad del comprador. Esta garantía limitada no cubre los daños debido a accidentes, abusos, uso inadecuado, negligencia, instalación inadecuada, mantenimiento inadecuado, o funcionamiento sin seguir las instrucciones suministradas por escrito por la compañía Wayne.
NO HAY NINGUNA OTRA GARANTIA EXPRESA O IMPLISITA. INCLUYENDO AQUELLAS SOBRE VENTA O USOS ESPECIFICOS, Y LAS GARANTIAS ESTAN LIMITADAS A 90 DIAS A PARTIR DE LA FECHA DE COMPRA. ESTA ES LA UNICA GARANTIA Y CUALQUIER PERDIDA O RESPONSABILIDAD CIVIL, SEA DIRECTA O INDIRECTA COMO CONSECUENCIA DE DAÑOS SON EXCLUIDAS.
Algunos estados no permiten límites en la duración de las garantías, o no permiten que se limiten o excluyan casos por daños por accidentes o consecuentes, en dichos casos los límites arriba enumerados tal vez no apliquen para Ud. Esta garantía limitada le otorga a Ud. ciertos derechos que pueden variar de un estado a otro. Bajo ninguna circunstyancia, aunque sea debido al incumplimiento del contrato de garantía, culpabilidad (incluyendo negligencia) u otras causas,la compañía Wayne o ninguno de sus surtidores serán responsables legalmente por ningún fallo legal en su contra, incluyendo, pero no limitado apérdida de ganancias, pérdidas del uso del producto o piezas asociadas con el equipo, pérdidas de capital, gastos para reemplazar los productos dañados, pérdidas por cierre de fábrica, servicios o pérdida de electricidad, o demandas persentadas por los clientes del comprador por dichos daños. Ud. DEBE conservar el recibo como prueba de compra junto con esta garantía. En caso de que necesite presentar un reclamo de sus derechos bajo esta garantía, Ud DEBERA enviar una copia del recibo de la tienda junto con el producto o correspondencia. Comuníquese con la compañía Wayne (800-237-0987, sólo desde EE.UU) para recibir autorización e instrucciones de como enviar la mercancía. NO ENVIE ESTOS DATOS A WAYNE. Conserve esto sólo como datos.
MODEL NO._____________________ NO. DE SERIE ________________________________ FECHA DE INSTALACION____________________
GRAPE SU RECIBO DE COMPRA AQUI
Operating Instructions and Parts Manual Instructions d’Utilisation et Manuel de Pièces Manual de Instrucciones de Operación y Piezas
For parts, product & service information
visit www.waynepumps.com
See Warranty on page 11 for important information about commercial use of this product.
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
Limited Warranty
For 90 days from date of purchase, Wayne Water Systems (”Wayne“) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (”Product“) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED FOR 90 DAYS FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such damages. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a COPY of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return authorization and instructions. DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._____________________ SERIAL NO.______________________________ INSTALLATION DATE __________________________
ATTACH YOUR RECEIPT HERE
Garantie Limitée
Pour 90 jours à compter de la date d’achat, Wayne Water Systems (“Wayne”) vas réparer ou remplacer, à son option, pour l’acheteur originel n’importe quelle pièce ou pièces de ces Pompes De Puisard ou Pompes À Eau (“Produit”) déterminées défectueuses, par Wayne, en matière ou en fabrication. S’il vous plaît appeler Wayne (800-237-0987) pour des instructions ou contacter votre marchand. S’assurer d’avoir, à votre disposition, le numéro du modèle afin d’effectuer cette garantie. Les frais de transportation des Produits ou pièces soumis pour la réparation ou le remplacement sont la responsabilité de l’acheteur. Cette Garantie Limitée ne couvre pas les Produits qui se sont fait endommagés en résultat d’un accident, utilisation abusive, mauvais usage, négligence, l’installation incorrecte, entretien incorrect, ou manque d’utilisation conformément aux instructions écrit de Wayne.
IL N’EXISTE AUCUNE AUTRE GARANTIE OU AFFIRMATION. LES GARANTIES EXPRIMÉES, Y COMPRIS CELLES DE COMMERCIALISABILITÉ ET D’ADAPTION POUR 90 JOURS À COMPTER DE LA DATE D’ACHAT. CECI EST LA REMÈDE EXCLUSIVE ET N’IMPORTE QUELLE RESPONSABILITÉ POUR N’IMPORTE QUEL ET TOUT DOMMAGES INDIRECTS OU DÉPENSES QUOI QUE SE SOIT EST EXCLUS.
Certaines Provinces n’autorisent pas de limitations de durée pour les garanties implicites, ni l’exclusion ni la limitation des dommages fortuits ou indirects. Les limitations précédentes peuvent donc ne pas s’appliquer. Cette garantie limitée donne, à l’acheteur, des droits légales précis, et vous pouvez avoir autres droits légales qui sont variable d’une Province ou d’un État à l’autre. En aucun cas, soit par suite d’un rupture de contrat de garantie, acte dommageable (y compris la négligence) ou autrement, ni Wayne ou ses fournisseurs seront responsables pour aucune dommage spéciale, incidentel ou pénal, y compris, mais pas limité à la perte de profits ou recettes, la perte d’usage des produits ou n’importe quel équipement associé, dommage à l’équipement associé, coût de capital, coût de produits remplaçants, aménagements, services ou abilité de remplaçement, coût de temps que le produit n’est pas en service, ou la réclamation des clients de l’acheteur pour ces dommages. Vous DEVEZ garder votre recette d’achat avec ce bulletin. Il est NÉCESSAIRE d’envoyer une COPIE de la recette d’achat avec le matériel ou correspondance afin d’effectuer une réclamation de la garantie. S’il vous plaît appeler Wayne (800-237-0987) pour l’autorisation et instructions concernant le renvoi. NE PAS ENVOYER, PAR LA POSTE, CE BULLETIN À WAYNE. Utiliser ce bulletin seulement pour vos archives.
Nº DU MODÈLE ______________________ Nº DE SÉRIE __________________________ DATE D’INSTALLATION ______________________
FIXER VOTRE FACTURE ICI
Operating Instructions and Parts Manual
Instructions d’Utilisation et Manuel de Pièces
Flood
risk. If flexible discharge hose is used, make sure pump is secured in sump pit to prevent movement. Failure to secure pump could allow pump movement and switch interference and prevent pump from starting or stopping.
IMPORTANT: Make sure there is adequate room for float switch to move freely during operation.
7. Protect electrical cord from sharp
object, hot surfaces, oil and chemicals. Avoid kinking the cord and replace damaged cords immediately.
8. A sump pit cover must be installed
to prevent debris from clogging or damaging the pump.
Risk of electrical shock! This pump is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock.
Never cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable.
9. Insert the float switch cord plug
directly into a 120 volt outlet (See Figure 3).
ADJUST AND TEST
1. Fill sump with water.
2. Adjust rubber grommet into a
permanent position on float rod so that the pump switches on with approximately 14” of water in the sump.
3. While the pump is draining the pit,
verify that the discharge piping is carrying the water to a point several feet away from the foundation.
Installation
1. A ground fault circuit interrupter (GFCI) is required.
2. This pump is for use on 120 Volt (single phase), 60 hz, 15 amp service and is equipped with a 3 conductor cord and a 3 prong grounding plug.
3. Install pump in a sump pit with minimum size as shown (See Figure
2). Construct sump pit of tile, concrete, steel or plastic.
4. Locate unit on a solid, level foundation. Do not place pump directly on clay, earth, gravel or sandy surface. These surfaces contain small stones, gravel, sand, etc. that may clog or damage the pump and cause pump failure (See Figure 2).
5. (Optional) Thread check valve (not included) into pump body carefully to avoid stripping or cross threading. Do not use pipe joint sealant.
6. Connect 1-1/4” rigid pipe to rubber boot on check valve. Reverse boot for 1-1/2” diameter pipe. Tighten hose clamps.
Support
pump and piping when assembling and after installation. Failure to do so could cause piping to break, pump to fail, etc. which could result in property damage and/or personal injury.
11
2
Operating Instructions and Parts Manual
4. If the pump discharge line is exposed to freezing temperature, the exposed line must be pitched to drain. Trapped water will freeze and damage the pump.
Check
battery once a month for proper alarm operation. Replace battery every six months and/or when local time change occurs.
Maintenance
Always disconnect the electrical supply before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only qualified electricians should repair this unit. Improper repair could result in fatal electrical shock.
1. Disassembly of the motor prior to
expiration of warranty will void the warranty. If repairs are required, see troubleshooting chart.
2. Keep pump inlet clean and free of
all foreign objects and inspect annually. A clogged inlet will damage pump.
3. Check pump monthly for proper
operation.
4. Note: Pump is equipped with an
automatic reset thermal protector.
Grounding
Blade
Grounded
Outlet
Power
Cord
TEST
RESET
Figure 3
24"
Min.
14" Dia. Min.
Grounded
Outlet
Figure 2
www.waynepumps.com
Loading...