5. Protect electrical cord from sharp objects, hot surfaces, oils, and chemicals. Avoid kinking the cord and replace damaged cords immediately.
IMPORTANT: Make sure there is adequate room for the switch to operate.
6. A sump pit cover must be installed to prevent debris from clogging or damaging the pump or interfering with pump.
Operation
Always disconnect the power source before attempting to install, service, relocate or maintain the pump. Never touch sump pump, pump motor, water or discharge piping when pump is connected to electrical power. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.
1. A ground fault circuit interrupter (GFCI) is required.
Risk of electrical
shock! This pump is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock.
Never cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable.
Installation
1. Install pump in a sump pit with minimum size as shown in Figure 1. Construct sump pit of tile, concrete, steel or plastic.
2. The unit should be located and rest on a solid, level foundation. Do not place pump directly on clay, earth, gravel or sandy surface. These surfaces contain small stones, gravel, sand, etc. that may clog or damage the pump and cause pump failure.
Flood risk. If
flexible discharge hose is used, make sure pump is secured in sump pit to prevent movement. Failure to secure pump could allow pump movement and switch interference and prevent pump from starting or stopping.
3. Thread check valve (Blue Angel™ offers
Model 66005-BLA1) into pump body carefully to avoid stripping or cross threading. Do not use pipe joint sealant.
4. Connect 1-1/2" rigid pipe to rubber boot
on check valve. Reverse boot for 1-1/4" diameter pipe. Tighten hose clamps.
Support pump and
piping when assembling and after installation. Failure to do so could cause piping to break, pump to fail, etc. which could result in property damage and/or personal injury.
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.
Description
The submersible pump is designed for indoor home sump applications. The unit is equipped with an 8-ft long, 3-prong grounding type power cord. Motor is oil filled and sealed for cooler running and designed to operate under water. A float switch is provided for automatic pump operation. This pump is not suitable for aquatic life.
General Safety Information
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Personal injury and/or property damage could result.
This pump is not
designed to handle salt water, brine, laundry discharge or any other application which may contain caustic chemicals and/or foreign materials. Pump damage could occur if used in these applications and will void warranty.
All wiring must be
performed by a qualified electrician. Failure to follow this warning could result in fatal electrical shock.
If the basement has water or moisture on the floor, do not walk on wet area until all power is turned off. If the shutoff box is in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.
A backup system
should be used. Blue Angel™ offers Model BSP15 and BSP25
Operating Instructions and Parts Manual BRSPT130
350800-002 1/07
Tether 14"
Min. Diameter
Submersible Sump Pump
14"
Figure 2
Grounded Outlet
24"
Figure 1
For parts, product & service information
visit www.blueangelpumps.com
© 2007 Blue Angel™ Pumps
5. While the pump is draining the pit, verify that the discharge piping is carrying the water to a point several feet away from the foundation.
If pump discharge
line is exposed to freezing temperature, the exposed line must be pitched to drain. Trapped water will freeze and damage the pump.
Maintenance
Always disconnect the electrical supply before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only qualified electricians
2. This pump is only for use on 120 Volt (single-phase), 60 hz, 15 amp service and is equipped with a 3-conductor cord and 3-prong, grounding type plug. Insert the float switch cord plug directly into a 120 volt outlet.
3. Insert the pump power cord plug directly into the back of the float switch cord plug (See Fig. 2).
4. Fill sump with water. The pump will start automatically when the water has filled the sump to the cut-in level. The pump will stop when the water reaches the cut-out level. See specifications for cut-in/out levels. The pump will cycle thereafter as required.
Do not operate the
pump unless it is submerged in water. Dry running causes pump failure.
The motor is
equipped with an automatic reset thermal protector.
2
Operating Instructions And Parts Manual
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Pump will not start or run
Pump starts and stops too often
Pump will not shut off or thermal protector turns off
Pump operates but delivers little or no water
1.Blown fuse
2.Low line voltage
3.Defective motor
4.Defective float switch
5.Impeller bound-up
6.Float obstructed
1.Backflow of water from piping
2.Faulty float switch
1.Defective float switch
2. Obstacle in piping
3.Float obstructed
1.Low line voltage
2.Plugged impeller
3.Obstructed piping
4. Excessive lift height (water has to go higher than pump can handle)
1.If blown, replace with proper sized fuse or reset breaker
2.If voltage is under 108 volts, check wiring size
3.Replace pump
4.Replace float switch
5.If impeller will not turn, remove housing and remove blockage
6.Make sure float moves freely up and down
1.Install or replace check valve (Blue Angel™ check valve kit #66005-WYN)
2.Replace float switch
1.Replace float switch
2.Remove pump and clean pump and piping
3.Make sure float move freely up and down
1.If voltage is under 108 volts, check wiring size
2.Clean out impeller
3.Remove pump and remove obstruction from piping or reposition piping to prevent obstruction
4.Reposition pump to a suitable position to decrease lift height
should repair this unit. Improper repair could result in fatal electrical shock.
1. Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under pressure and the motor is hot.
2. Disassembly of the motor prior to expiration of warranty will void the warranty. If repairs are required, see troubleshooting chart.
3. Inlet should be kept clean and free of all foreign objects and inspected annually. A clogged inlet will damage the pump.
4. Pump should be checked monthly for proper operation.
This pump contains
dielectric oil for cooling. This oil can be harmful to the environment. Check the state environmental laws before disposing this oil.
www.blueangelpumps.com
3
BRSPT130
1 Tether Float Switch Kit 60022-001 2 Power Cord Kit 62003-001 3 Impeller 28541-001 4 Impeller Retaining Clip 67106-001
Ref. Parts Numbers No. Description RSP-130
For Replacement Parts, call 1-888-636-6628
Please provide following information:
- Model number
- Serial number (if any)
- Part descriptions and number as shown in parts list
Address parts correspondence to:
Blue Angel™ 101 Production Drive Harrison, OH 45030 U.S.A.
Replacement Parts List
• Only use factory parts to repair this pump.
1
2
www.blueangelpumps.com
Specifications
Power supply requirements.............120V, 60 hz
Motor................................................Single phase, oil filled
Liquid temperature range...............40°F to 120°F
Circuit requirements ........................15 amps (min)
Dimensions .......................................11" high x 9" base
Cut-in level (factory set) ..................Tether ...14"
Cut-out level (factory set)................Tether...7"
Construction
Motor housing .................................Glass reinforced thermoplastic
Volute ...............................................Thermoplastic
Base ...................................................Thermoplastic
Impeller.............................................Glass reinforced thermoplastic
Shaft..................................................Stainless steel
Seals ..................................................Buna N
Discharge ..........................................11/2" NPT
4
Limited Warranty
For one year from the date of purchase, Blue Angel™ will repair or re place, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel™ to be defective in materials or work man ship. Please call Blue Angel™ (888-636-6628) for instructions or see your dealer. Be pre pared to provide the model number and the serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Blue Angel™’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, IN CLUD ING THOSE OF MER CHANT ­ABIL I TY AND FITNESS FOR A PARTICULAR PUR POSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAM AG ES OR EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above lim i ta tions might not apply to you. This limited war ran ty gives you specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (in clud ing negligence) or otherwise, shall Blue Angel™ or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equip ment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s cus tom ers for such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Blue Angel™ (888-636-6628) for return authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION DATE_____________
ATTACH YOUR RECEIPT HERE
Operating Instructions And Parts Manual
www.blueangelpumps.com
Loading...
+ 8 hidden pages