Wayne 351301-001, TSC User Manual

Submersible Utility Pump
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop­erty damage! Retain instructions for future reference.
© 2000 Wayne Water Systems
Operating Instructions and Parts Manual TSC
Risk of electric shock! This pump has not been tested for use in swimming pool areas. Never place pump in pools while people are in the water.
Do not handle pump with wet hands or when standing in water or on a damp surface.
Risk of electric shock! This pump is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock.
This pump con-
tains dielectric motor oil for motor heat transfer. Care should be taken when disposing of this oil. Do not use this pump in ponds or fountains because the motor oil can be harmful to aquatic life.
2. Wear safety glasses at all
times when working with pumps.
3. It is strongly recommended
that this unit be plugged into a Ground Fault Circuit Interrupter (GFCI). Consult a local electrician for installation and availability.
4. Do not use the power cord or dis-
charge hose to carry or handle the pump. Damage to the power cord or discharge hose may occur. Use the lifting ring supplied on the pump.
351301-001 1/00
Installation and Operation
Always disconnect electric supply before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and TAG IN OPEN (OFF) POSITION to pre­vent unexpected power application. Failure to do so could result in fatal electrical shock!
This unit is not designed for use in septic tanks or under­ground vaults to pump raw sewage or effluents. Never use in hazardous or explosive locations.
1. This pump has been designed to attach to a standard garden hose. Thread the female end of the gar­den hose to the male discharge on the pump.
2. To reduce leakage between the pump and the hose, place a hose washer (not included) on the gar­den hose before installing to the pump.
3. For best pump performance, unwind the hose before starting the pump. This will help remove any kinks or binds in the hose and allow the unit to pump with less restriction.
4. Set the pump on a hard surface in the water. Do not set the pump directly on mud or sand surfaces. This will cause the inlet screen to clog.
5. The water level must be at least 1/2 inches for the pump to operate. Water levels less than 1/2 inches will not allow the impeller to contact water and no water will be pumped.
Description
This portable, submersible utility pump is designed for non-automatic use in water. The units are equipped with an 8 ft. 3-prong grounding type power cord. The motor is oil filled and sealed for cooler operation. The discharge fit­ting is designed for convenient attach­ment to a garden hose.
IMPORTANT: THIS PUMP IS NOT SUITABLE FOR AQUATIC LIFE!
Unpacking
After unpacking the unit, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts.
Danger indicates
an imminently haz­ardous situation which, if not avoided, WILL result in death or serious injury.
Warning indicates
a potentially haz­ardous situation which, if not avoided, COULD result in death or serious injury.
Caution indicates a
potentially haz­ardous situation which, if not avoided, MAY result in minor or moderate injury.
Notice indicates
important informa­tion, that if not followed, MAY cause damage to equipment.
This manual contains information that is very important to know and under­stand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following:
1. Read these rules and
instructions carefully. Failure to follow these instructions could cause serious bodily injury and/or proper­ty damage.
Very Important Safety Information
2
Operating Instructions and Parts Manual
Installation and Operation
(Continued)
Do not handle pump with wet hands or when standing in water or on a damp surface when the unit is operating or fails to operate. Always disconnect pump power cord from power source before handling.
6. Plug the power cord into a ground­ed 115-volt AC power outlet. The pump will start operating as soon as the power cord is plugged into the power outlet.
7. The pump will remove water down to 1/8 inches of the hard surface the pump was placed on.
8. The pump should be turned off once the water level reaches the 1/8-inch mark.
Do not allow
pump to run dry. The shaft seal depends on water for lubrication. Operating pump without water will damage the shaft seal and cause pump failure.
Maintenance
Always disconnect electric supply before attempting to install, service, relocate or per­form any maintenance. Failure to do so could result in fatal electrical shock.
Minimal service is required for this pump. If pump should fail to operate, perform the following troubleshooting guidelines:
1. The motor housing of the
pump is completely sealed and requires no service. Disassembly of the motor housing or alteration of the power cord could result in fatal electrical shock.
2. Verify pump is operating correctly.
a. Disconnect pump from power
source.
b. Disconnect discharge hose from
pump.
c. Immerse pump in a bucket or tub
of water.
d. Plug power cord into a grounded
115 volt AC power outlet. If pump operates correctly proceed to step #3. If pump does NOT
operate, unplug power cord and proceed to maintenance guide­line item 4 in this section.
3. Verify discharge hose is correctly installed.
a. Connect hose to another water
source such as a faucet. If water flows through hose, proceed to step 3b. If water is restricted, ver­ify discharge hose is unwound. Remove all kinks, bends or obstructions in hose.
b. Verify pumping height does NOT
exceed 25 feet (See Figure 1). If pumping height is greater than 25 feet, this pump will NOT work.
4. Periodic cleaning of pump is required to maintain performance of the pump. Follow the cleaning steps listed below:
a. Unplug the power cord.
b. Remove the 3 screws at the bot-
tom of the pump.
c. Remove the volute cover. Note
the alignment marks.
d. Remove the gasket. Note how
the openings in the gasket align with the openings in the pump base.
e. Remove the debris and make sure
the impeller turns freely.
Figure 1 Water Level
25 Ft. Max.
Water Level
f. Replace the gasket making sure
the openings are aligned.
g. Replace the volute cover.
h. Replace the 3 screws.
3
Operating Instructions and Parts Manual
For Replacement Parts, call 1-800-237-0987
Please provide following information:
- Model number
- Serial number (if any)
- Part description and number as shown in parts list
Address parts correspondence to:
Wayne Water Systems 100 Production Drive Harrison, OH 45030 U.S.A.
1 Power cord 31006-002 31006-002 1
2 Discharge fitting 15875 15875-002 1
3 Outer housing with o-ring 28053-001 28053-001 1
19023-001 19023-001 1
4 Impeller 23097 23097 1
5 Volute gasket 23122 23122 1
6 Volute cover with screen 28056-001 28056-002 1
Ref. No. Description TSC130/250 TSC160 Qty.
1
2
3
4
5
6
4
Operating Instructions and Parts Manual
Limited Warranty
For one year from the date of purchase, Wayne Water Systems Division ("Wayne") will repair or re place, at its option, for
the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by
Wayne to be defective in materials or work man ship. Please call Wayne (800-237-0987) for instructions or see your dealer.
Be pre pared to provide the model number and the serial number when exercising this warranty. All transportation
charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect,
improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, IN CLUD ING THOSE OF MER CHANT ABIL I TY
AND FITNESS FOR A PARTICULAR PUR POSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. THIS IS
THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAM AG ES OR
EXPENSES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations
of incidental or consequential damages, so the above lim i ta tions might not apply to you. This limited war ran ty gives you
specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (in clud ing negligence) or otherwise, shall Wayne or
its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of prof-
it or revenues, loss of use of the products or any associated equipment, damage to associated equip ment, cost of capital,
cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s cus tom ers for
such damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you
MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987)
for return authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO._______________ SERIAL NO.__________________________ INSTALLATION DATE_____________
ATTACH YOUR RECEIPT HERE
Loading...