TECHNICAL DATA
INSTALLATION GUIDE
Linear potentiometer Series LRW2, LRW3
For further information please see the data s heet at www.waycon.biz/products/linear-potentiometers/
TECHNICAL DRAWING
Useful electrical stroke B: corresponds to the sensors measurement range
Theoretical electrical stroke C: actual length of the conductive path, that has to be longer than B, in order
to get a valid electrical signal at the start and end point of the measurem ent range.
When c alibrating the transducer, be careful to set the stroke so that the output does not drop below 1%
or rise above 99% of the voltage level.
ACCESSORIES
LRW2-C with ball tip and connector output
LRW3-C with roller tip and connector output
LRW2-F, LRW3-F wi th cable output
CON011: mating connector for LRW2-C, LRW3-C
for self assembly,
IP40, 5 pole,
cable diameter 4...6 mm
Spare p art s
PTAS000 spare ball tip
(LRW2: included in delivery)
PTAS001 spare roller tip
(LRW3: included in delivery)
PKIT005 mounting kit brackets
(LRW2, LRW3: included in delivery )
Usef ul electrical stroke (B) +1/-0 [mm] 10 25 50 75 100 150
Theoretical electrical s troke (C) ±1 [mm] B + 1
Resistance 1 1 5 5 5 5
Linearity [%] ±0.3 ±0.2 ±0.1 ±0.1 ±0.1 ±0.05
Dissipation at 40°C (0 W at 120 °C ) [W] 0.2 0.6 1.2 1.8 2.4 3.6
Maximum applicable voltage [V] 14 25 60 60 60 60
Mechanical strok e (D) [mm] B + 5
Case length (A) [mm] B + 38
Tip length (E) LRW2 [mm] 32 32 40 40 40 40
Tip length (E) LRW3 [mm] 43 43 51 - - -
Total length LRW2 [mm] 108 138 196 251 307 426
Total length LRW3 [mm] 119 149 207 - - -
[kOhm]
PMX-24 Signal Conditioner
•
Converts potentiometer signals into analog output
signals: 4...20 mA, 0...10 V, 0...5 V, ±10 V, ±5 V
•
Input: potentiometer 1...20 k Ω
•
Configurable output
•
DIN-rail-mounting with face-side connector
•
For further information please
check the PMX-24 data sheet,
or contact WayCon