Wavetronix LLC
TM
SmartSensor HD
User’s Manual
www.SmartSensor.us
TM
SS 126
Version 1.0
March 13, 2013
5314 N. 250 W., Suite 110, Provo, UT 84604, USA (801) 764-0277
TMTM
Wavetronix LLC
Wavetronix Contact Information .................................................................................................... 2
Copyright / Trademarks .................................................................................................................. 2
Product Notifications ...................................................................................................................... 3
Introduction ..................................................................................................................................... 5
Unpacking ....................................................................................................................................... 6
Installing the SmartSensor .............................................................................................................. 7
Step 1 – Assemble the Mounting Bracket................................................................................... 7
Step 2 – Attach the SmartSensor to the Mounting Bracket ........................................................ 7
Step 3 - Mount SmartSensor on a Pole ....................................................................................... 8
Step 4 – Connect SmartSensor Cable ......................................................................................... 8
Step 4 – Connect SmartSensor Cable ......................................................................................... 9
Step 5 – Configure the SmartSensor ......................................................................................... 10
Step 5.1 - Installing the SmartSensor Manager Software ..................................................... 10
Step 5.2 - Connecting Your Computer to the SmartSensor .................................................. 11
Serial Cable – there are two serial options available for connecting to the SmartSensor: ....... 11
Serial Connection .............................................................................................................. 12
Modem Connection ................................................................. Error! Bookmark not defined.
Internet Connection ........................................................................................................... 13
Additional Features of the SmartSensor Manager .................................................................... 16
Manual Configuration ....................................................................................................... 16
Saving the Configuration .................................................................................................. 16
Undoing Manual Changes................................................................................................. 16
Restarting LaneSmart ........................................................................................................ 16
Using Data Viewing and Logging Tools .............................................................................. 16
Event Data ......................................................................................................................... 16
Time-Interval Data ............................................................................................................ 16
Using the SmartSensor Manager Menu ................................................................................ 16
Connection ........................................................................................................................ 16
LaneSmart ......................................................................................................................... 16
TrafficView ....................................................................................................................... 16
Data Logs .......................................................................................................................... 17
Firmware Upload .............................................................................................................. 17
Appendix ....................................................................................................................................... 17
RS-232 Communication Port ..................................................................................................... 18
RS-485 Communication Port ..................................................................................................... 18
1
TMTM
Wavetronix LLC
Wavetronix Contact Information
380 S. Technology Ct.
Lindon, Utah 840424 USA
Voice: (801) 764-0277
Fax: (801) 764-0208
Web: www.smartsensor.us
E-mail: sales@smartsensor.us
Or
support@smartsensor.us
Copyright / Trademarks
© Copyright 2002 Wavetronix LLC, All rights reserved.
SmartSensor, the SmartSensor logo and LaneSmart are trademarks of Wavetronix LLC. SeaLINK
is a trademark of Sealevel Systems Inc. All other product or brand names as they appear are
trademarks or registered trademarks of their respective holders.
The Company shall not be liable for any errors contained herein or for any damages arising out of
or related to this document or the information contained therein, even if the Company has been
advised of the possibility of such damages.
This document is intended for informational and instructional purposes only. The Company
reserves the right to make changes in the specifications and other information contained in this
document without prior notification.
2
TMTM
Product Notifications
FCC Part 15 Compliance
Wavetronix LLC
Risk of Electrical Shock
This equipment complies with Part 15 of the FCC (Federal Communications
Commission) rules. Any changes or modifications not expressly approved by
the manufacturer could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
An authorized electrical technician should perform installation and operation of
this unit. Persons other than authorized and approved electrical technicians
should NOT attempt to connect this unit to a power supply and/or traffic control
cabinet, as there is a serious risk of electrical shock through unsafe handling of
the power source. Extreme caution should be used when connecting this unit to
an active power supply.
Technical Service
Do not attempt to service or repair this unit. This unit does not contain any
components and/or parts serviceable in the field. Any attempt to open this unit,
except as expressly written and directed by Wavetronix will void the customer
Warranty. Any visible damage to exterior seal labels will void the Warranty.
Wavetronix is not liable for any bodily harm or damage caused if unqualified
persons attempt service or open the back cover of this unit. Refer all service
questions to Wavetronix or an authorized distributor.
Installation Safety Precaution
Caution should be used when installing any sensor on or around active
roadways. Serious injury can result when installation is performed using
methods that are not in accordance with authorized local safety policy and
procedures. Always maintain an appropriate awareness of the traffic conditions
3
TMTM
and safety procedures as they relate to specific locations and installations.
Symbol Legend
The lightning bolt within an equilateral triangle symbol is intended to alert the user to
the risk of electric shock.
The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important installation, operating, and maintenance instructions.
Wavetronix LLC
4
TMTM
Introduction
The Wavetronix SmartSensor HD traffic sensor utilizes the latest technology to collect and
deliver traffic statistics. Capable of measuring traffic volume, average speed, individual vehicle
speed, lane occupancy and presence, the SmartSensor HD collects information through the use of
a 24.125 GHz (K band) operating radio frequency. Classified as Frequency Modulated
Continuous Wave (FMCW) radar, the SmartSensor HD detects and reports traffic conditions
simultaneously over as many as ten lanes of traffic. Once SmartSensor HD is installed, the
configuration process is quick and easy. After installation, this unit will require little or no onsite maintenance, and can be remotely reconfigured for optimal performance. The following
pages detail the easy step-by-step process of getting started with the SmartSensor HD.
Wavetronix LLC
5