Wavetronix Click 330 Quick Reference Manual

Page 1
Click 330 Ethernet Switch
INSTALLER QUICK-REFERENCE GUIDE
2
Wire power
Unlike many other Click devices, the Click 330 does not mount over the T-bus, meaning that power and communications will have to be wired in into the device’s six screw terminals. e rst four screw terminals, marked US1, GND, US2 and GND, are for wiring power. (e other two, which are labeled R1 and R2, are for security and functionality alarm purposes.)
1 Attach the device to a location on the DIN rail that is not over a
T-bus.
2 Attach a wire for +DC (red is standard) to the screw terminal
marked US1.
3 Attach a wire for -DC (black is standard) to the rst screw termi-
nal marked GND.
4 Attach the other ends of these two wires to a DC power source.
Note. US2 and the second GND are for wiring in a redundant power
supply, if you’d like to use one.
www.wavetronix.com
801.734.7200
1
Mount the device
e Click 330 mounts on a DIN rail. To mount, simply hook the lip over the lower edge of the DIN rail, and use a rocking motion to snap the module into place.
Note. Do not mount over the T-bus.
Page 2
© 2015 Wavetronix LLC. All rights reserved. Protected by US Pat. Nos. 6,556,916; 6,693,557; 7,426,450; 7,427,930; 7,573,400; 7,889,097; 7,889,098; 7,924,170; 7,991,542; 8,248,272; 8,665,113; and Cdn. Pat. Nos. 2,461,411; 2,434,756; 2,512,689; and Euro. Pat. Nos. 1435036; 1438702; 1611458. Other US and international patents pending. Wavetronix, SmartSensor, Click, Com­mand and all associated logos are trademarks of Wavetronix LLC. All other product or brand names as they appear are trademarks or registered trademarks of their respective holders. Product specifications are subject to change without notice. This material is provided for informational purposes only; Wavetronix assumes no liability related to its use.
3
Ground the device
4
Wire communication
Attach Ethernet cables to the RJ-45 jacks on the Click 330.
e device has a grounding foot, so as long as the DIN rail is properly grounded, the device will be grounded as well.
However, for additional protection, the switch can be grounded via an eyelet ring on the top of the device.
WX-500-0188
5
Monitor LEDs
e Click 330 has two dierent kinds of LEDs.
˽ At the top of each device are two green LEDs
labeled US1 and US2, used for monitoring the power supply. US1 monitors the rst power supply (the one using the screw terminal marked US1) and US2 monitors the second (redundant) power supply.
˽ Each Ethernet port has two LEDs that show the data transmission speed of that port, as shown in the
table below. ese LEDs are labeled 100/ACT and 1000/ACT. If the LED is on, there is an electrical link. If the LED blinks, there is currently network trac at that speed.
LED 10 Mbps 100 Mbps 1000 Mbps
100/ACT On or blinking On or blinking O
1000/ACT On or blinking O On or blinking
Status Meaning
On Supply voltage is in an acceptable range
O Supply voltage is too low
Loading...