2.3.5 Input/output electrical characteristics defined for all external connections6
2.3.6 Protection/on-board network connection6
3. DESCRIPTION OF THE INTERFACES7
3.1 LED Function7
3.2 Connectors7
4. TECHNICAL DATA11
Wavecom WMOD2B Modem
SUMMARY
5. TROUBLESHOOTING: Specific defaults possibly encountered12
5.1 The modem does not answer through the serial link12
5.2 The modem always returns «Error» when trying to issue a communication13
5.3 The modem always returns «No carrier» when trying to issue a communication14
6. REFERENCE ACCESSORIES16
7. NOTES ON SAFETY16
7.1 General safety16
7.2 Vehicle safety17
7.3 Car And Maintenance17
7.4 Your responsibility18
8. GENERAL INFORMATIONS19
SUMMARY
Wavecom WMOD2B Modem
1. PRODUCT DESCRIPTION
The Wavecom WMOD2B is a dual-band E-GSM 900/1800 modem.
1.1Package content
The Wavecom WMOD2B modem package comprises:
- 1 Modem
- 2 holding bridles
- 1 Power supply cable + fuse
- 1 User manual (this document)
1.2Product presentation
The Wavecom WMOD2B modem supports DATA and FAX transmission, Short Messages (Point to Point and Cell Broadcast)
and VOICE calls.
The connectors binded to the body guarantee output and input connections.
An extractible holder is used to insert the SIM card (Micro-SIM type). A LED indicates the operating mode.
For mounting the modem, bind to the body the holding bridles according to the schema below:
Note:
- To be attached to a plain surface
- Screw head max. height: 2mm
Holding bridles
Figure 2
Modem mounting
2.2Installing the modem
To install the modem, plug the device on a DC power supply (for automotive applications, connect the device on the
permanent « + » and insert the SIM card in the holder).
Make sure that an antenna is connected.
2
mm
2 mm
In order to extract or to insert the Micro SIM card, it is necessary to press the SIM holder ejector
with a sharp element (a pen for example).
If this sequence is not respected, the SIM holder could be damaged.
Wavecom WMOD2B Modem3
INSTALLATION/START-UP
2.3Electrical characteristics
2.3.1 Switching the GSM modem on/off
The device is permanently powered (when connected to the power supply).
2.3.2 Voltage range
Voltage range:5 to 32V DC
GND:0V
2.3.3 Overvoltage/undervoltage
Correct operation of the Wavecom WMOD2B modem in communication mode is not guaranteed if input voltage
fall below 5V. The modem is protected against voltage over 32V.
When input voltages exceed 32V, the supply voltage is disconnected in order to protect the electronic components from an
overvoltage.
TWO CASES ARE POSSIBLE:
- IF THE OVERVOLTAGE IS CONTINUOUS, THE PROTECTION IS GUARANTEED BY THE FUSE.
- IN THE CASE OF TRANSIENT PEAKS, THE MODEM GUARANTEES ITS OWN PROTECTION.
INSTALLATION/START-UP