ET-809
Insulation-Continuity Tester
User Manual

Wavecom Instruments Insulation-Continuity Tester User Manual
Index
Safety Precautions....................................................... 1-2
Safety Notes................................................................ 3
Features....................................................................... 3-4
Connections................................................................. 4
Specifications............................................................... 5
Why Test is Necessary................................................. 6
Instrument Layout........................................................ 7
Simplified Instructions.................................................. 8-9
Preparation for Measurement...................................... 9
Functions..................................................................... 10-16
Battery & Fuse Replacement....................................... 17
Calibration & Servicing................................................ 17
Cleaning & Storage..................................................... 17

Wavecom Instruments Insulation-Continuity Tester User Manual
1. Safety Precautions
Electricity can cause severe injuries even with low voltages or currents.
Therefore it is extremely important that you read the following
information before using your analogue tester.
1.1 This Instrument must only be used and operated by a
competent trained person and in strict accordance with the instructions.
Wavecom will not accept liability for any damage or injury caused by
misuse or non compliance with instructions and safety procedures.
1.2 This instrument must not be used on live circuits. Ensure
all circuits are de-energised before testing. See paragraph 1.8 for
details of built-in warning features should your analog insulation tester
be connected to a live system.
1.3 Never open your analogue insulation tester except for
battery replacement. (see battery replacement section)
1.4 Always inspect you analog insulation tester and test
leads before use for any sign of abnormality or damage. If any
abnormal conditions exist (broken test leads, cracked case, display
faulty etc...) do not attempt to take any measurement or use the tester.
Return your analogue insulation tester to your nearest distributor for
service.
1.5 Never replace the protective fuse with any other than the specified or
equivalent
1.6 Your analogue insulation tester has been designed with
your safety in mind. However, no design can completely protect
against incorrect use. Electrical circuits can be dangerous and / or
lethal when a lack of caution or poor safety practice is used.

Wavecom Instruments Insulation-Continuity Tester User Manual
Use with caution in the presence of voltage above 24V as
these pose a shock hazard.
1.7 Pay attention to cautions and warnings which will inform
you of potentially dangerous procedures.
1.8 Your analogue insulation tester has a live circuit warning
beeper. If it is connected to an AC live circuit, a beep of twice the
frequency of the voltage present will be heard.
DO NOT proceed to test and immediately disconnect the
instrument from the circuit. In addition, the warning light will
illuminate if the voltage is above 100Vdc or 70Vac.
When AC voltage is present, before testing, it's value is
displayed on the AC scale.

Wavecom Instruments Insulation-Continuity Tester User Manual
2. Safety Notes
Rated environmental condition
(1) Indoor use.
(2) Installation Category Ⅲ.
(3) Pollution Degree 2.
(4) Altitude up to 2000M.
(5) Relative humidity 80% Max.
(6) Ambient temperature 0°C~40°C.
Meter is protected throughout by double insulation or reinforced
insulation.
Warning ! risk of electric shock.
Caution ! refer to this manual before using the meter.
3. Features
● High quality taut band movement.
● Three insulation test voltages:
1- 250Vdc 100MΩ
2- 500Vdc 200MΩ
3- 1000Vdc 400MΩ
● Two continuity test on "Low Ohms":
1- 500Ω
2- 3Ω
● Small and Lightweight.
● AC voltmeter with linear scale up to 500Vac.
● 205mA continuity short circuit current.
● 1mA test current on insulation test at nominal voltage.
● Automatic discharge of capacitance and inductive circuit off
charge stored in the circuit under test..

Wavecom Instruments Insulation-Continuity Tester User Manual
● Live Warning and display of external voltage presence.
● Fuse and overload protected.
● On line battery monitoring shows if battery is ok.
● Very low battery consumption.
● On-Load battery check (+/-205mA load for worst case).
● Operates on 8 dry batteries AA, R6P type.
● Mirrored scale for easy and accurate reading.
● Push and turn locking switch for long and hand free testing.
● Supplied with high quality test leads.
● Meets:
LVD IEC/EN 61010-1
EMC EN 61326-1:2006 CLASS B
EN 61326-1:2006
EN 61000-4-2:2001
EN 61000-4-3:2007
4. Connections