BOILER OPERATION AND ADJUSTMENT PROCEDURES FOR USERS
Before turning on the boiler read the following warnings carefully .
Make sure that the warranty booklet carries the stamp of the CORGI registered technician (you can check this by contacting corgi on 01256.372200) responsible for installing the boiler. Installation, starting up for the first time, adjustments and maintenance operations must all be carried out solely by qualified technicians. Incorrect installation may cause damage to persons, animals or property for which the manufacturer cannot be held liable.
WARNING!
Do not start the boiler unless you are sure it has been thoroughly tested by an authorised technician. Check that the regulations regarding air intakes and ventilation of the room where the boiler is installed have been
fully complied with (see installation instructions p.2).
The anti-freeze system will come into operation only if the boiler is in the «ON» position (with selector switch 1 in
fig. 1 turned to the summer or winter position) and the gas supply turned on. The manufacturer can accept no responsibility for damage to the boiler caused by lack of observation of these requirements.
If the boiler should freeze up, under no circumstances attempt to turn it on but call the RADIANT HELP LINE
immediately.
LEGEND
1.
2.
3.
(see fig. 1)
SUMMER-WINTER ON-OFF SWITCH HEATING TEMPERATURE ADJUSTMENT KNOB SPACE FOR ADDING AN OPTIONAL TIMER
SELF- DIAGNOSTIC LEGEND
4.
WARNING: LACK OF WATER IN THE SYSTEM
5.
WATER PRESSURE LEVEL 1 BAR
6.
WATER PRESSURE LEVEL 1.5 BAR
7.
WARNING: LOCK-OUT INDICATOR
(see fig. 2)
TURNING ON THE ELECRONIC (by flame
3
AUT
OFF
Fig. 1
ON
2
60°
50°
40°
30°
ELECTRONIC WATER
PRESSURE GAUGE
456 7
1
OFF
70°
80°
50°
45°
1.5
1.50.5 1
55°
60°
40°
STOP
ionisation)
Open the gas cock under the boiler grill;
1.5
STOP
Turn selector switch 1 to the  symbol denoting winter (see fig.1).
0.5
1.5
1
Make sure that 5 and 6 lights are ON (fig.2, page I, pos. 5 and 6); if light no. 4 is ON, it
Fig. 2
means water deficiency in the system: open the tap on the filling loop and fill the system until a pressure of 1.5 bar has been reached (light no. 6 ON; fig.2) and then close the tap.
The automatic ignition system will turn the boiler on. It may be necessary to repeat the procedure a few times to purge air from the pipes. To repeat the ignition procedure in any case wait 3 minutes before turning the boiler off and on again, then try to ignite it once more.
TURNING OFF THE ELECRONIC IGNITION
set selector switch 1 to the OFF position; if the boiler will not be used for long periods it is recommended that the gas cock under the boiler grill be shut off.
REGULATING THE HEATING TEMPERATURE
The heating temperature is regulated by turning knob 2 (see fig.1) to the temperature required, chosen from the different values printed around the selector. The temperature range goes from a minimum of 35°C to a maximum of 80°C.