Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. Watts reserves the right to change or modify product design, construction, specifications or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.
©Watts 2010 Version 4.0 1130
Page 2
ScaleNet®Commercial Water Treatment Systems
The Problem
Calcium creates scale in pipes, on appliances and other plumbing surfaces. This leads to higher heating and energy costs and expensive repairs to appliances, such as ice machines, coffee makers, dishwashers and cooling towers in commercial buildings.
Scale can also be a source or bacteria to grow, which can be a health concern in drinking water applications.
Calcium, on the other hand, is important to human health, and supplements are recommended if Calcium is reduced or totally void in one's diet.
The Solution
Watts ScaleNet®Treatment Systems transform Calcium ions into Calcium crystals, which are stable and cannot attach to pipes,surfaces, hardware or heat exchanger components. The crystals are so small they are easily rinsed away by the water flow.
Benefits
Scale is virtually
eliminated!
Aids in removing
existing scale.
No costly repairs to
appliances due to scale.
No salt.
No brine tank.
No backwash.
Saves water!
No electricity.
Easy installation.
Note: For satisfactory results recommended flow rates and model sizing must be followed.
Models
Part Number
M8407-COM 7x44 Standard 1" 2.5 NA 10 10x10x51 30 M8408-COM 8x44 Standard 1" 3 NA 12 11x11x51 32 M8409-COM 9x48 Standard 1" 4 NA 16 12x12x42 35 M8410-COM 10x54 Standard 1" 5 NA 20 13x13x61 37 M8412-COM 12x52 Standard 1" 7.5 NA 30 15x15x59 45 M8414-COM 14x65 Standard 2" * 12.5 NA 50 20x20x79 77 M8416-COM 16x65 Standard 2" * 19 NA 75 20x20x79 138
*Units with 2” plumbing have a bottom inlet and top outlet. Dimensions listed do not include outlet plumbing.
Note: Commercial systems are designed for long runs and high usage. By-pass valves are optional. Maximum hardness is 75 grains per gallon at specified flow rates. based on 25 grains hardness, maximum. Consult dealer for sizing in higher levels. Do not use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit. System must be maintained according to manufacturer's instructions. Manganese, hydrocarbons and copper may be required depending on conditions. Install systems in new facilities with copper pipe after six weeks of water use
Tank Size
(Inches)
Tank Type
Pipe Size
(Inches)
Media Liters
Gravel
Lbs.
Service
Flow GPM
Pre-treatment for sediment, Iron, Hydrogen Sulfide,
Floor Space
L x W x H
(Inches)
Ship Wt.
(Lbs.)
Flow rates are
.
Page 3
Proven Results!
Lab tests conducted at the Watts test facility, located in San Antonio, Texas indicate ScaleNet
®
anti-scale media virtually eliminates new scale formation and aids in the removal of existing scale. Tests were conducted in water temperatures to 140°F and hardness levels of 17 grains per gallon. Photos (below) show scale formation in untreated water and no scale in the ScaleNet treated water.
ScaleNet®Cartridges
We also supply cartridges with ScaleNet anti-scale media for low flow applications.
PART NUMBER SIZE FLOW (MAX.)
SNC2510 2.5"x 10" 1 gpm
SNC2520 2.5"x 20" 2 gpm
SNC4510 4.5"x 10" 3 gpm
SNC4520 4.5"x 20" 4 gpm
Scale Build-Up
(In untreated water).
No Scale!
(With ScaleNet treatment).
ScaleNet®Commercial Water Treatment Systems
Page 4
ScaleNet®Commercial Water Treatment Systems
ScaleNet® Commercial Water Treatment Systems
Installation – 1" Pipe
The flow thru the Commercial Anti-Scale System is upward. Therefore, the inlet and outlet connections are opposite of traditional water treatment equipment.
The flow rate must not exceed the maximum specified flow rate of the system. A flow control devise will be required for applications where flow rates may exceed the maximum specified flow rate.
Part No. Tank Size Pipe Size Max Service Flow
M8407-COM 7x44 1" 10 gpm M8408-COM 8x44 1" 12 gpm M8409-COM 9x48 1" 16 gpm M8410-COM 10x54 1" 20 gpm M8412-COM 12x52 1" 30 gpm
Installation Instructions:
1. Place system on a smooth flat surface.
2. Install the fittings and / or the bypass (see separate instructions). Slide the nut on first then the split ring and o-ring.
3. Connect incoming cold water to the inlet of the system.
4. Connect system outlet to service water of the house.
5. Partially open a valve down stream of the system to allow the air to purge from the system.
6. Slowly open inlet valve and allow the system to fill with water.
7. Close the down stream valve five minutes after all the air has been purged from the system and plumbing. This flushes any fines out of the system.
8. Check for leaks and repair as required.
9. System is ready for use.
Conditions for Operation:
Minimum pressure 15 PSI
Maximum pressure 125 PSI
Minimum operating temperature 34 F
Maximum operating temperature 120 F
Water pH range 6.0 to 9.0
Maximum feed water hardness is 75 grains per gallon.
Hydrogen sulfide, iron, and manganese
Pre-treatment required
Maximum chlorine 3 ppm, de-chlorination recommended
Oil and grease should not be present
Warning - Do not exceed specified flow rates
Note: Do not use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit. System must be maintained according to manufacturer's instructions. Pre-treatment for sediment, Iron, Hydrogen Sulfide, Manganese, hydrocarbons and copper may be required depending on conditions. Install systems in new facilities with copper pipe after six weeks of water use.
Top view with optional bypass
Inlet
Outlet
Page 5
ScaleNet®Commercial Water Treatment Systems
ScaleNet® Commercial Water Treatment Systems
Installation – 2" Pipe
The flow thru the ScaleNet® Commercial Water Treatment System is upward. Therefore, the inlet connection is at the bottom of the tank and outlet connection is at the top.
The flow rate must not exceed the maximum specified flow rate of the system. A flow control devise will be required for applications where flow rates may exceed the maximum specified flow rate.
Part Number Tank Size Pipe Size Max Service Flow
M8414-COM 14x65 2" 50 gpm
M8416-COM 16x65 2" 75 gpm
Installation Instructions:
1. Place system on a smooth flat surface.
2. It is recommended that the system is installed with a field constructed 3 valve bypass.
3. Connect incoming cold water to the inlet of the system.
4. Connect system outlet to the service water line in the building.
5. Partially open a valve down stream of the system to allow the air to purge from the system.
6. Slowly open inlet valve and allow the system to fill with water.
7. Close the down stream valve five minutes after all the air has been purged from the system and plumbing. This flushes any fines out of the system.
8. Check for leaks and repair as required.
9. System is ready for use.
Conditions for Operation:
Minimum pressure 15 PSI
Maximum pressure 125 PSI
Minimum operating temperature 34 F
Maximum operating temperature 120 F
Water pH range 6.0 to 9.0
Maximum feed water hardness is 75 grains per gallon.
Hydrogen sulfide, iron, and manganese pretreatment required
Maximum chlorine 3 ppm, de-chlorination recommended
Oil and grease should not be present
Warning - Do not exceed specified flow rates
Outlet
Inlet
Note: Do not use where water is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the unit. System must be maintained according to manufacturer's instructions. Pre-treatment for sediment, Iron, Hydrogen Sulfide, Manganese, hydrocarbons and copper may be required depending on conditions. Install systems in new homes with copper pipe after six weeks of water use.
Page 6
ScaleNet®Commercial Water Treatment Systems
ScaleNet®Commercial Water Treatment Systems
LIMITED WARRANTY
Watts Water Quality & Conditioning Products warrants its Commercial Anti‐Scale tank systems as follows:
• Tanks having diameters of 6" to 13" are warranted to be free of defects in materials and workmanship for 10 years from the date of original installation or 123 months from date of original shipment, whichever comes irst.
• Tanks having diameters 14" or larger are warranted to be free of defects in materials and workmanship for 5 years from the date of original installation or 63 months from date of original shipment, whichever comes irst.
• The head is warranted to be free of defects in materials and workmanship for 5 years from date of original installation or 63 months from date of original shipment, whichever comes irst.
• The ScaleNet
®
media is warranted for performance for a period of 2 years from the date of the original installation or 27 months from original date of shipment,
whichever comes irst, when installed and operated in accordance with the instructions in the corresponding Installation and Operation Manual.
Watts Water Quality & Conditioning Products warrants its ScaleNet
®
cartridge system as follows:
• The ScaleNet
®
cartridge system is warranted to be free of defects in materials and workmanship for 1 year from the date of original installation or 15 months
from the date of original shipment, whichever comes irst.
• ScaleNet
®
cartridges are warranted for performance for a period of one year from the date of original installation when installed and operated in accordance with
the instructions in the corresponding Installation and Operation Manual.
• Carbon replacement ilter cartridges are not warranted to perform for any period of time because the service life of replacement carbon ilter cartridges varies signiicantly with local water conditions and volume.
Conditions
1. The Commercial Anti‐Scale System must be installed and serviced by an authorized Watts Water Quality & Conditioning Products dealer or Watts approved entity.
2. Any component failure must not result from abuse, ire, freezing or other acts of nature, violence, or improper installation.
3. Equipment must be installed and operated in compliance with the local plumbing codes and on an approved water supply that does not exceed speciication of
the system.
4. Equipment is limited to use at water pressures not to exceed 100psi and temperatures not to exceed 110 degrees F.
5. Water supply must not exceed 2.0‐PPM chlorine. For water supply exceeding 2.0 PPM chlorine, pretreatment is required. (Please contact your water treatment
specialist.)
6. Water supply must not exceed 0.3 mg/l iron, 0.05 mg/l manganese, 1.3 mg/l copper, oil/hydrogen sulide/phosphates none allowed. Copper
usually originates from new copper plumbing. We recommend six weeks of use prior to placing the E‐Treat™ systems in service. For water supply exceeding these limitations, pretreatment is required. (Please contact your water treatment specialist.)
7. Information, including model number, serial number, and date of installation, must be provided for any claims pertaining to equipment in warranty.
8. Defective parts are subject to inspection by either Watts Water Quality & Conditioning Products or any authorized representative before inal commitment of
warranty adjustment is made.
9. Watts Water Quality & Conditioning Products reserves the right to make changes or substitutions in parts or equipment with material of equal quality or value
and of then current production.
10. This warranty shall not apply to any Commercial Anti‐Scale System system installed or used for residential applications. For purposes of this warranty, a
residential application is an application for a building with 4 or fewer dwelling units.
Limitations
Our obligation under this warranty with respect to the tank or valve is limited to furnishing a replacement for, or at our option, repairing any part or parts to our sat‐ isfaction that prove defective within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. nearest factory, at no cost, exclud‐ ing freight and local labor charges, if any.
Our obligation under this warranty with respect to the ScaleNet
®
media will be limited to furnishing a replacement for the media within two years from date of origi‐ nal installation. Such replacement media will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor charges, if any. Damage to the media due to chlorine, other oxidizers or fouling caused by local water conditions or any other operation outside of the limits shown under speciications, is not covered by this warranty.
THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY WATTS WATER QUALITY & CONDITIONING PRODUCTS WITH RESPECT TO THE PRODUCT. WATTS WATER QUALITY & CONDITIONING PRODUCTS MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. WATTS WATER QUALITY & CONDITIONING PRODUCTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
The remedy described under this warranty shall constitute the sole and exclusive remedy for breach of warranty, and Watts Water Quality & Conditioning Products shall not be responsible for any incidental, special or consequential damages, including without limitation, freight, handling, lost proits or the cost of repairing or replacing other property which is damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical, or any other circumstances over which Watts Water Quality & Conditioning Products has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product.
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations may not apply to you. This warranty gives you speciic legal rights, and you may have other rights that vary from state to state. You should consult applicable state laws to determine your rights. SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW, ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DU‐ RATION TO THE APPLICABLE WARRANTY PERIODS STATED ABOVE.
ScaleNet®Commercial Anti-Scale Systems
Loading...