PUMP CONTROL VALVE with
2
3
4
5
6
8
X
X
CLOSES VALVE
OPENS VALVE
FLOW
1
X
Y/FC
X
5
7
PRESSURE REDUCING FEATURE
01/05
Stainless Series
• Opens at adjustable rate on pump start-up
• Closes at adjustable rate on pump shut-off
• Limit Switch turns pump off when valve closes
S113-29 or S6113-29 (Globe)
S1113-29 or S61113-29 (Angle)
• Throttles to reduce higher inlet pressure to
constant lower outlet pressure (adjustable)
• Hydraulic Check Feature prevents flow reversal
• Solenoid equipped with Manual Operator
• Pressure Reducing setpoint is adjustable
STANDARD COMPONENTS OPTIONS and ACCESSORIES
1 - Main Valve (Single Chamber)
2 - Fig.22 Accelerator Control
3 - Limit Switch
4 - 3-Way Solenoid
5 - Check Valve
6 - Adjustable Opening Speed
7 - Adjustable Closing Speed
8 - Pressure Reducing Control
° X - Isolation Cocks (STANDARD)
° FC - Flo-Clean Strainer (OPTIONAL)
° Y - Y-Strainer (STANDARD)
° L - Dual Limit Switch
8550 Hansen Road • Houston, Texas 77075 • (Ph) 713.943.0688 • (Fx) 713.944.9445 • www.wattsacv.com